The feasibility of dual-energy CT in differentiation of vertebral compression fractures

被引:64
|
作者
Karaca, Leyla [1 ]
Yuceler, Zeynep [1 ,2 ]
Kantarci, Mecit [1 ]
Cakir, Murteza [3 ]
Sade, Recep [1 ]
Calikoglu, Cagatay [3 ]
Ogul, Hayri [1 ]
Bayrakturan, U. Gulsum [1 ]
机构
[1] Ataturk Univ, Sch Med, Dept Radiol, Erzurum, Turkey
[2] Eregli State Hosp, Dept Radiol, Zonguldak, Turkey
[3] Ataturk Univ, Sch Med, Dept Neurosurg, Erzurum, Turkey
来源
BRITISH JOURNAL OF RADIOLOGY | 2016年 / 89卷 / 1057期
关键词
BONE-MARROW LESIONS; VIRTUAL NONCALCIUM TECHNIQUE; MULTIDETECTOR CT; PERCUTANEOUS VERTEBROPLASTY; COMPUTED-TOMOGRAPHY; INITIAL-EXPERIENCE; PERFORMANCE; EDEMA; RECOGNITION;
D O I
10.1259/bjr.20150300
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective: To prospectively evaluate the ability of dual-energy CT (DECT), compared with MRI, to identify vertebral compression fractures in acute trauma patients. Methods: This institutional review board-approved study included 23 consecutive patients with 32 vertebral fractures who underwent both DECT and MRI of the spine between February 2014 and September 2014. A total of 209 vertebrae were evaluated for the presence of abnormal bone marrow attenuation on DECT and signal on MRI by five experienced radiologists. The specificity, sensitivity, predictive values and intraobserver and interobserver agreements were calculated. Results: MRI revealed a total of 47 vertebrae (22.4% of all vertebrae) and DECT revealed 44 vertebrae (21.0% of all vertebrae) with oedema. Using MRI as the reference standard, DECT had sensitivity, specificity, positive-predictive value, negative-predictive value and accuracy of 89.3, 98.7, 95.4, 96.9 and 96.6%, respectively. With respect to establishing the presence of oedema, the interobserver agreement was almost perfect (k=0.82), and the intraobserver agreement was substantial (k=0.80). Conclusion: Compared with MRI, DECT can provide an accurate demonstration of acute vertebral fractures and can be used as an alternative imaging modality for the assessment of vertebral fractures in patients with contraindications for MRI. Advances in knowledge: Distinguishing of acute and chronic vertebral compression fracture is important for treatment choices. DECT is very fast compared with MRI and is an alternative imaging modality for the assessment of vertebral fractures in patients with contraindications for MRI.
引用
收藏
页数:6
相关论文
共 50 条
  • [21] Vertebral morphometry by dual-energy X-ray absorptiometry (DXA) for osteoporotic vertebral fractures assessment (VFA)
    Diacinti, D.
    Guglielmi, G.
    Pisani, D.
    Diacinti, D.
    Argiro, R.
    Serafini, C.
    Romagnoli, E.
    Minisola, S.
    Catalano, C.
    David, V.
    RADIOLOGIA MEDICA, 2012, 117 (08): : 1374 - 1385
  • [22] Utilization of a two-material decomposition from a single-source, dual-energy CT in acute traumatic vertebral fractures
    Tivnan, Patrick
    Kaliaev, Artem
    Anderson, Stephan W.
    LeBedis, Christina A.
    Li, Baojun
    Andreu-Arasa, V. Carlota
    FRONTIERS IN RADIOLOGY, 2023, 3
  • [23] Differentiation of malignant cervical lymphadenopathy by dual-energy CT: a preliminary analysis
    Yang, Liang
    Luo, Dehong
    Li, Lin
    Zhao, Yanfeng
    Lin, Meng
    Guo, Wei
    Zhou, Chunwu
    SCIENTIFIC REPORTS, 2016, 6
  • [24] Dual-energy CT of the abdomen
    Desiree E. Morgan
    Abdominal Imaging, 2014, 39 : 108 - 134
  • [25] Dual-energy CT of the abdomen
    Morgan, Desiree E.
    ABDOMINAL IMAGING, 2014, 39 (01): : 108 - 134
  • [26] Differentiation of malignant cervical lymphadenopathy by dual-energy CT: a preliminary analysis
    Liang Yang
    Dehong Luo
    Lin Li
    Yanfeng Zhao
    Meng Lin
    Wei Guo
    Chunwu Zhou
    Scientific Reports, 6
  • [27] Dual-Energy CT of the Pancreas
    Mastrodicasa, Domenico
    Delli Pizzi, Andrea
    Patel, Bhavik Natvar
    SEMINARS IN ULTRASOUND CT AND MRI, 2019, 40 (06) : 509 - 514
  • [28] Dual-Energy CT of the Lung
    Lu, Guang Ming
    Zhao, Yan'E
    Zhang, Long Jiang
    Schoepf, U. Joseph
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2012, 199 (05) : S40 - S53
  • [29] Nonuniqueness in dual-energy CT
    Levine, Zachary H.
    MEDICAL PHYSICS, 2017, 44 (09) : E202 - E206
  • [30] Dual-Energy CT of the Heart
    Vliegenthart, Rozemarijn
    Pelgrim, Gert Jan
    Ebersberger, Ullrich
    Rowe, Garrett W.
    Oudkerk, Matthijs
    Schoepf, U. Joseph
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2012, 199 (05) : S54 - S63