MRI-induced artifact by a cochlear implant with a novel magnet system: an experimental cadaver study

被引:12
|
作者
Canzi, Pietro [1 ]
Aprile, Federico [1 ]
Simoncelli, Anna [2 ]
Manfrin, Marco [1 ]
Magnetto, Marianna [1 ]
Lafe, Elvis [2 ]
Minervini, Domenico [1 ]
Avato, Irene [3 ,4 ]
Terrani, Simone [5 ]
Scribante, Andrea [3 ]
Gazibegovic, Dzemal [6 ]
Benazzo, Marco [1 ]
机构
[1] Univ Pavia, Fdn IRCCS Policlin San Matteo, Dept Otorhinolaryngol, Viale Camillo Golgi 19, I-27100 Pavia, Italy
[2] Univ Pavia, IRCCS Policlin San Matteo Fdn, Dept Diagnost Radiol & Intervent Radiol & Neurora, Pavia, Italy
[3] Univ Pavia, Dept Clin Surg Diagnost & Pediat Sci, Pavia, Italy
[4] Univ Pavia, Pavia, Italy
[5] Clin Applicat Specialist MR ISP, Philips, Netherlands
[6] AB GmbH, European Res Ctr ERC, Hannover, Germany
关键词
Cochlear implant; Artifacts; Magnetic resonance imaging; Cadaver; Ultra; 3D; 1.5; TESLA; SAFETY;
D O I
10.1007/s00405-020-06464-z
中图分类号
R76 [耳鼻咽喉科学];
学科分类号
100213 ;
摘要
Purposes To primarily evaluate MRI-induced effects for Ultra 3D cochlear implantation in human cadavers in terms of artifact generation and MR image quality. Methods Three human cadaveric heads were submitted to imaging after unilateral and bilateral cochlear implantation. The 1.5 T MR examination protocol was chosen in accordance with our institutional protocol for the assessment of brain pathology. The maximal signal void size was measured according to each sequence and plane. Two experienced neuro-radiologists and one experienced otoneurosurgeon independently evaluated the MR image quality findings. A 4-point scale was used to describe the diagnostic usefulness of 14 brain structures. Results Shape and size of the artifacts were found to be highly related to MRI sequences and acquisition planes. MRI sequences and processing algorithms affected the ability to assess anatomical visibility. Image quality appeared either high or assessable for diagnostic purposes in 9 out of 14 of the ipsilateral structures, in at least one plane. Anatomical structures contralateral to the cochlear implant were highly visible in all conditions. Artifact intrusion clearly improved after application of metal artifact-reduction techniques. In the case of bilateral cochlear implant, a mutual interaction between the two implant magnets produced an additional artifact. Conclusions We performed the first cadaver study aimed at systematically evaluating the MRI-induced artifacts produced by a cochlear implant with a novel four bar magnet system. Specific brain structures can be assessable for diagnostic purposes under 1.5 T MRI, with the cochlear implant magnet in place.
引用
收藏
页码:3753 / 3762
页数:10
相关论文
共 50 条
  • [31] Customized Cochlear Implant Positioning in a Patient With a Low- Grade Glioma: Towards the Best MRI Artifact Management
    Canzi, Pietro
    Luzzi, Sabino
    Carlotto, Elena
    Simoncelli, Anna
    Brondino, Natascia
    Marconi, Stefania
    Magnetto, Marianna
    Lucifero, Giotta A.
    Avato, Irene
    Manfrin, Marco
    Auricchio, Ferdinando
    Preda, Lorenzo
    Benazzo, Marco
    OTOLOGY & NEUROTOLOGY, 2022, 43 (06) : E628 - E633
  • [32] An Optically Coupled System for Quantitative Monitoring of MRI-Induced RF Currents Into Long Conductors
    Zanchi, Marta G.
    Venook, Ross
    Pauly, John M.
    Scott, Greig C.
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2010, 29 (01) : 169 - 178
  • [33] Focused tight dressing does not prevent cochlear implant magnet migration under 1.5 Tesla MRI
    Cuda, D.
    Murri, A.
    Succo, G.
    ACTA OTORHINOLARYNGOLOGICA ITALICA, 2013, 33 (02) : 133 - 136
  • [34] A novel guided zygomatic implant surgery system compared to free hand: A human cadaver study on accuracy
    Grecchi, E.
    Stefanelli, L., V
    Grecchi, F.
    Grivetto, F.
    Franchina, A.
    Pranno, N.
    JOURNAL OF DENTISTRY, 2022, 119
  • [35] MRI-Induced Heating of Coils for Microscopic Magnetic Stimulation at 1.5 Tesla: An Initial Study
    Bonmassar, Giorgio
    Serano, Peter
    FRONTIERS IN HUMAN NEUROSCIENCE, 2020, 14
  • [36] Evaluation of 4 multisection CT systems in postoperative imaging of a cochlear implant: A human cadaver and phantom study
    Verbist, B. M.
    Joemai, R. M. S.
    Teeuwisse, W. M.
    Veldkamp, W. J. H.
    Geleijns, J.
    Frijns, J. H. M.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2008, 29 (07) : 1382 - 1388
  • [37] Magnetically Steered Robotic Insertion of Cochlear-Implant Electrode Arrays: System Integration and First-In-Cadaver Results
    Bruns, Trevor L.
    Riojas, Katherine E.
    Ropella, Dominick S.
    Cavilla, Matt S.
    Petruska, Andrew J.
    Freeman, Michael H.
    Labadie, Robert F.
    Abbott, Jake J.
    Webster, Robert J., III
    IEEE ROBOTICS AND AUTOMATION LETTERS, 2020, 5 (02) : 2240 - 2247
  • [38] Contemporary Staining of Arterial System with Cadaver Fixation: An Experimental Study
    Ghorbani, Rostam
    Tavakol, Zahra
    Ghanbari, Ali
    INTERNATIONAL JOURNAL OF MORPHOLOGY, 2012, 30 (03): : 1079 - 1084
  • [39] Metal Artifact Reduction With Tin Prefiltration in Computed Tomography A Cadaver Study for Comparison With Other Novel Techniques
    Hackenbroch, Carsten
    Schuele, Simone
    Halt, Daniel
    Zengerle, Laura
    Beer, Meinrad
    INVESTIGATIVE RADIOLOGY, 2022, 57 (03) : 194 - 203
  • [40] Experimental assessment of clinical MRI-induced global SAR distributions in head phantoms (vol 66, pg 113, 2019)
    Blackwell, J.
    Oluniran, G.
    Tuohy, B.
    Krasny, M. J.
    Destrade, M.
    Colgan, N.
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2023, 112