MRI-Induced Heating of Coils for Microscopic Magnetic Stimulation at 1.5 Tesla: An Initial Study

被引:16
|
作者
Bonmassar, Giorgio [1 ]
Serano, Peter [1 ,2 ]
机构
[1] Harvard Med Sch, Athinoula A Martinos Ctr, Massachusetts Gen Hosp, Charlestown, MA 02129 USA
[2] ANSYS Inc, Canonsburg, PA USA
来源
基金
美国国家卫生研究院;
关键词
finite elements method; RF-induced heating; specif absorption rate; bioheat equation; deep brain stimulation implant; DEEP BRAIN-STIMULATION; ELECTRICAL-STIMULATION; ABSORPTION RATE; IN-VITRO; IMPLANT; SYSTEMS; TEMPERATURE; SIMULATION; ELECTRODES; RECOVERY;
D O I
10.3389/fnhum.2020.00053
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
Purpose Deep brain stimulation (DBS) has proved to be effective in the treatment of movement disorders. However, the direct contact between the metal contacts of the DBS electrode and the brain can cause RF heating in magnetic resonance imaging (MRI) scanning, due to an increase of local specific absorption rate (SAR). Recently, micro coils (mu MS) have demonstrated excitation of neuronal tissue through the electromagnetic induction both in vitro and in vivo experiments. In contrast to electrical stimulation, in mu MS, there is no direct contact between the metal and the biological tissue. Methods We compared the heating of a mu MS coil with a control case of a metal wire. The heating was induced by RF fields in a 1.5 T MRI head birdcage coil (often used for imaging patients with implants) at 64 MHz, and normalized results to 3.2 W/kg whole head average SAR. Results The mu MS coil or wire implants were placed inside an anatomically accurate head saline-gel filled phantom inserted in the RF coil, and we observed approximately 1 degrees C initial temperature rise at the mu MS coil, while the wire exhibited a 10 degrees C temperature rise in the proximity of the exposed end. The numerical simulations showed a 32-times increase of local SAR induced at the tips of the metal wire compared to the mu MS. Conclusion In this work, we show with measurements and electromagnetic numerical simulations that the RF-induced increase in local SAR and induced heating during MRI scanning can be greatly reduced by using magnetic stimulation with the proposed mu MS technology.
引用
收藏
页数:10
相关论文
共 50 条
  • [1] MRI-induced heating of deep brain stimulation leads
    Mohsin, Syed A.
    Sheikh, Noor M.
    Saeed, Usman
    PHYSICS IN MEDICINE AND BIOLOGY, 2008, 53 (20): : 5745 - 5756
  • [2] Modeling of MRI-induced Heating in Pacemaker Patients during 1.5T MRI Scans
    Mouchawar, G.
    Sison, S.
    Chen, S.
    Min, X.
    Chen, J.
    Nyenhuis, J.
    Gutfinger, D.
    Williamson, R.
    2015 COMPUTING IN CARDIOLOGY CONFERENCE (CINC), 2015, 42 : 769 - 772
  • [3] SACRAL NEUROMODULATION AND MRI SAFETY: AN EX VIVO INVESTIGATION OF MRI-INDUCED HEATING OF THE INTERSTIM DURING HEAD IMAGING AT 1.5-AND 3-TESLA
    Knoepp, Leise R.
    Shellock, Frank G.
    Chen, Chi Chiung Grace
    Wright, Edward J.
    NEUROUROLOGY AND URODYNAMICS, 2012, 31 (02) : 242 - 242
  • [4] MRI-induced lead heating of an MRI conditional pacemaker system
    Mouchawar, G.
    Sison, S.
    Chen, S.
    Min, X.
    Chen, J.
    Nyenhuis, J.
    Williamson, R.
    EUROPEAN HEART JOURNAL, 2015, 36 : 350 - 350
  • [5] Simple design changes to wires to substantially reduce MRI-induced heating at 1.5 T: implications for implanted leads
    Gray, RW
    Bibens, WT
    Shellock, FG
    MAGNETIC RESONANCE IMAGING, 2005, 23 (08) : 887 - 891
  • [6] MRI-induced stimulation of peripheral nerves: dependency of stimulation threshold on patient positioning
    Faber, SC
    Hoffmann, A
    Ruedig, C
    Reiser, M
    MAGNETIC RESONANCE IMAGING, 2003, 21 (07) : 715 - 724
  • [7] MRI-Induced DBS electrode heating: Important laboratory variables
    Nazzaro, Jules M.
    Daniluk, Slawomir
    ANNALS OF NEUROLOGY, 2006, 60 : S79 - S79
  • [8] Neurostimulation systems used for deep brain stimulation: In vitro assessment of MRI-related heating at 1.5-Tesla
    Finelli, D
    Rezai, AR
    Tkach, J
    Rugieri, P
    Nyenhuis, J
    Shellock, FG
    RADIOLOGY, 2002, 222 (02) : 586 - 586
  • [9] Numerical Investigations of MRI RF-induced Heating for Passive Implants in Birdcage and TEM Body Coils at 3 Tesla
    Yang, Rui
    Zheng, Jianfeng
    Song, Shuo
    Guo, Ran
    Chen, Ji
    2020 IEEE INTERNATIONAL SYMPOSIUM ON ELECTROMAGNETIC COMPATIBILITY AND SIGNAL & POWER INTEGRITY VIRTUAL SYMPOSIUM(IEEE EMC+SIPI), 2020, : 261 - 265
  • [10] 3-Tesla MRI for the evaluation of myocardial viability: a comparative study with 1.5-Tesla MRI
    Ligabue, G.
    Fiocchi, F.
    Ferraresi, S.
    Barbieri, A.
    Rossi, R.
    Modena, M. G.
    Romagnoli, R.
    Torricelli, P.
    RADIOLOGIA MEDICA, 2008, 113 (03): : 347 - 362