MRI-Induced Heating of Coils for Microscopic Magnetic Stimulation at 1.5 Tesla: An Initial Study

被引:16
|
作者
Bonmassar, Giorgio [1 ]
Serano, Peter [1 ,2 ]
机构
[1] Harvard Med Sch, Athinoula A Martinos Ctr, Massachusetts Gen Hosp, Charlestown, MA 02129 USA
[2] ANSYS Inc, Canonsburg, PA USA
来源
基金
美国国家卫生研究院;
关键词
finite elements method; RF-induced heating; specif absorption rate; bioheat equation; deep brain stimulation implant; DEEP BRAIN-STIMULATION; ELECTRICAL-STIMULATION; ABSORPTION RATE; IN-VITRO; IMPLANT; SYSTEMS; TEMPERATURE; SIMULATION; ELECTRODES; RECOVERY;
D O I
10.3389/fnhum.2020.00053
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
Purpose Deep brain stimulation (DBS) has proved to be effective in the treatment of movement disorders. However, the direct contact between the metal contacts of the DBS electrode and the brain can cause RF heating in magnetic resonance imaging (MRI) scanning, due to an increase of local specific absorption rate (SAR). Recently, micro coils (mu MS) have demonstrated excitation of neuronal tissue through the electromagnetic induction both in vitro and in vivo experiments. In contrast to electrical stimulation, in mu MS, there is no direct contact between the metal and the biological tissue. Methods We compared the heating of a mu MS coil with a control case of a metal wire. The heating was induced by RF fields in a 1.5 T MRI head birdcage coil (often used for imaging patients with implants) at 64 MHz, and normalized results to 3.2 W/kg whole head average SAR. Results The mu MS coil or wire implants were placed inside an anatomically accurate head saline-gel filled phantom inserted in the RF coil, and we observed approximately 1 degrees C initial temperature rise at the mu MS coil, while the wire exhibited a 10 degrees C temperature rise in the proximity of the exposed end. The numerical simulations showed a 32-times increase of local SAR induced at the tips of the metal wire compared to the mu MS. Conclusion In this work, we show with measurements and electromagnetic numerical simulations that the RF-induced increase in local SAR and induced heating during MRI scanning can be greatly reduced by using magnetic stimulation with the proposed mu MS technology.
引用
收藏
页数:10
相关论文
共 50 条
  • [41] Homogeneous Phantom Model vs. Visible Human Dataset: Impact on MRI-induced Heating of Metal Implants
    Mattei, Eugenio
    Calcagnini, Giovanni
    Censi, Federica
    Triventi, Michele
    Bartolini, Pietro
    PIERS 2011 MARRAKESH: PROGRESS IN ELECTROMAGNETICS RESEARCH SYMPOSIUM, 2011, : 639 - 642
  • [42] LUMBOSACRAL 1.5 TESLA MRI COMPATIBILITY WITH SACRAL NEUROMODULATION: AN IN-VIVO PROSPECTIVE STUDY
    Guzman-Negron, Juan M.
    Pizarro-Berdichevsky, Javier
    Gill, Bradley
    Goldman, Howard B.
    NEUROUROLOGY AND URODYNAMICS, 2018, 37 : S561 - S562
  • [43] Voltage-Based Device Tracking in a 1.5 Tesla MRI During Imaging: Initial Validation in Swine Models
    Schmidt, Ehud J.
    Tse, Zion T. H.
    Reichlin, Tobias R.
    Michaud, Gregory F.
    Watkins, Ronald D.
    Butts-Pauly, Kim
    Kwong, Raymond Y.
    Stevenson, William
    Schweitzer, Jeffrey
    Byrd, Israel
    Dumoulin, Charles L.
    MAGNETIC RESONANCE IN MEDICINE, 2014, 71 (03) : 1197 - 1209
  • [44] Complex Difference Constrained Compressed Sensing Reconstruction for Accelerated PRF Thermometry with Application to MRI-Induced RF Heating
    Cao, Zhipeng
    Oh, Sukhoon
    Otazo, Ricardo
    Sica, Christopher T.
    Griswold, Mark A.
    Collins, Christopher M.
    MAGNETIC RESONANCE IN MEDICINE, 2015, 73 (04) : 1420 - 1431
  • [45] LUMBOSACRAL 1.5 TESLA MRI COMPATIBILITY WITH SACRAL NEUROMODULATION: AN IN-VIVO PROSPECTIVE STUDY
    Guzman-Negron, Juan M.
    Pizarro-Berdichevsky, Javier
    Gill, Bradley
    Goldman, Howard B.
    JOURNAL OF UROLOGY, 2018, 199 (04): : E970 - E970
  • [46] Brain lactate responses during visual stimulation in fasting and hyperglycemic subjects: A proton magnetic resonance spectroscopy study at 1.5 Tesla
    Maddock, Richard J.
    Buonocore, Michael H.
    Lavoie, Shawn P.
    Copeland, Linda E.
    Kile, Shawn J.
    Richards, Anne L.
    Ryan, John M.
    PSYCHIATRY RESEARCH-NEUROIMAGING, 2006, 148 (01) : 47 - 54
  • [47] Ex Vivo Study of Artifacts Caused by Breast Tissue Markers with Different 1.5 Tesla and 3 Tesla MRI Scanners - A Bicentric Study
    Puesken, Michael
    Unterberg-Buchwald, Christina
    Rhiem, Kerstin
    Hokamp, Nils Grosse
    Maintz, David
    Lotz, Joachim
    Wienbeck, Susanne
    ACADEMIC RADIOLOGY, 2021, 28 (01) : 77 - 84
  • [48] Preliminary Study of RF-Induced Heating of DBS and RNS Devices under 1.5 T MRI
    Akter, Mir Khadiza
    Guo, Ran
    Islam, Md Zahidul
    Zheng, Jianfeng
    Chen, Ji
    2024 IEEE INTERNATIONAL SYMPOSIUM ON ANTENNAS AND PROPAGATION AND INC/USNCURSI RADIO SCIENCE MEETING, AP-S/INC-USNC-URSI 2024, 2024, : 2655 - 2656
  • [49] Prediction of Clinical Deep Brain Stimulation Target for Essential Tremor From 1.5 Tesla MRI Anatomical Landmarks
    Engelhardt, Julien
    Cuny, Emmanuel
    Guehl, Dominique
    Burbaud, Pierre
    Damon-Perriere, Nathalie
    Dallies-Labourdette, Camille
    Thomas, Juliette
    Branchard, Olivier
    Schmitt, Louise-Amelie
    Gassa, Narimane
    Zemzemi, Nejib
    FRONTIERS IN NEUROLOGY, 2021, 12
  • [50] MRI-Induced Neurosensory Events in Decorative Black Tattoos: Study by Advanced Experimental Methods
    Alsing, Kasper Kohler
    Olsen, Ole
    Koch, Christian Bender
    Hansen, Rasmus Hvass
    Persson, Daniel Pergament
    Qvortrup, Klaus
    Serup, Jorgen
    CASE REPORTS IN DERMATOLOGY, 2023, 15 (01): : 85 - 92