In-Tube Solid-Phase Microextraction and Liquid Chromatography Using a Monolithic Column for the Selective Determination of Residual Ethylenediamine in Industrial Cationic Polymers

被引:15
|
作者
Prieto-Blanco, M. C. [2 ]
Lopez-Mahia, P. [2 ]
Campins-Falco, P. [1 ]
机构
[1] Univ Valencia, Fac Quim, Dept Quim Analit, E-46100 Valencia, Spain
[2] Univ A Coruna, Fac Ciencias, Dept Quim Analit, E-15071 La Coruna, Spain
关键词
PRECOLUMN DERIVATIZATION; WATER SAMPLES; AMINES; POLYAMINES; STABILITY; HPLC;
D O I
10.1021/ac900796j
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The selective determination of the diamine ethylenediamine (EDA) in the presence of a higher amount of residual dimethylamine in cationic polymers has been developed. The strategy uses both a solution derivatization with a selective agent of primary amines such as o-phthaldialdehyde-N-acetyl-L-cysteine (OPA-NAC) and an in-tube solid-phase microextraction (IT-SPME) coupled to liquid chromatography (LC). A 70 cm long, 0.32 mm internal diameter, and 3 mu m thick commercially available capillary column coated with 95% polydimethylsiloxane and 5% polydiphenylsiloxane was employed to replace the injection loop of a Rheodyne injection valve. A volume of 1 mL of derivatized sample was passed through the capillary, and 100 mu L of water was later used for cleaning and filling the capillary. After, the injection was effected and the desorption of the derivative from the capillary was carried out in the dynamic mode using the mobile phase. Chromatographic separation was performed in less than 2 min using a monolithic silica column Onyx (100 mm x 3.0 mm i.d.) under isocratic conditions. The effect of several parameters affecting derivatization and IT-SPME was investigated. The quantification of EDA was realized over the range of 0.07-2 mu g/mL with adequate linearity, accuracy, and reproducibility, and the limit of detection was 20 ng/mL The method is rapid and low in cost, and sample handling and organic solvent consumption have been minimized. Its application to polymeric cationic surfactants used in water treatment allowed the selective quantification of residual EDA at low microgram per milliliter levels of concentration without off-line preconcentration.
引用
下载
收藏
页码:5827 / 5832
页数:6
相关论文
共 50 条
  • [1] Monolithic silica column for in-tube solid-phase microextraction coupled to high-performance liquid chromatography
    Shintani, Y
    Zhou, X
    Furuno, M
    Minakuchi, H
    Nakanishi, K
    JOURNAL OF CHROMATOGRAPHY A, 2003, 985 (1-2) : 351 - 357
  • [2] Automated on-line in-tube solid-phase microextraction-assisted derivatization coupled to liquid chromatography for quantifying residual dimethylamine in cationic polymers
    Prieto-Blanco, M. C.
    Chafer-Pericas, C.
    Lopez-Mahia, P.
    Campins-Falco, P.
    JOURNAL OF CHROMATOGRAPHY A, 2008, 1188 (02) : 118 - 123
  • [3] Urea-formaldehyde monolithic column for hydrophilic in-tube solid-phase microextraction of aminoglycosides
    Wang, Jiabin
    Zhao, Qi
    Jiang, Nan
    Li, Wenbang
    Chen, Li
    Lin, Xucong
    Xie, Zenghong
    You, Lijun
    Zhang, Qiqing
    JOURNAL OF CHROMATOGRAPHY A, 2017, 1485 : 24 - 31
  • [4] Automated determination of rifampicin in plasma samples by in-tube solid-phase microextraction coupled with liquid chromatography
    Melo, L. P.
    Queiroz, R. H. C.
    Queiroz, M. E. C.
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2011, 879 (24): : 2454 - 2458
  • [5] Determination of fluoroquinolones in eggs using in-tube solid-phase microextraction coupled to high-performance liquid chromatography
    Jing-Fang Huang
    Bo Lin
    Qiong-Wei Yu
    Yu-Qi Feng
    Analytical and Bioanalytical Chemistry, 2006, 384 : 1228 - 1235
  • [6] Determination of fluoroquinolones in eggs using in-tube solid-phase microextraction coupled to high-performance liquid chromatography
    Huang, JF
    Lin, B
    Yu, QW
    Feng, YQ
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2006, 384 (05) : 1228 - 1235
  • [7] Boronate affinity monolithic column incorporated with graphene oxide for the in-tube solid-phase microextraction of glycoproteins
    Wang, Rong
    Chen, Zilin
    JOURNAL OF SEPARATION SCIENCE, 2018, 41 (13) : 2767 - 2773
  • [8] Hybrid organic-inorganic octyl monolithic column for in-tube solid-phase microextraction coupled to capillary high-performance liquid chromatography
    Zheng, Ming-Ming
    Lin, Bo
    Feng, Yu-Qi
    JOURNAL OF CHROMATOGRAPHY A, 2007, 1164 (1-2) : 48 - 55
  • [9] In-tube molecularly imprinted polymer solid-phase microextraction for the selective determination of propranolol
    Mullett, WM
    Martin, P
    Pawliszyn, J
    ANALYTICAL CHEMISTRY, 2001, 73 (11) : 2383 - 2389
  • [10] Simple and rapid determination of linear alkylbenzene sulfonates by in-tube solid-phase microextraction coupled with liquid chromatography
    Hirayama, Yuichi
    Ikegami, Hiroshi
    Machida, Motoi
    Tatsumoto, Hideki
    JOURNAL OF HEALTH SCIENCE, 2006, 52 (03) : 228 - 236