Urea-formaldehyde monolithic column for hydrophilic in-tube solid-phase microextraction of aminoglycosides
被引:0
|作者:
Wang, Jiabin
[1
]
Zhao, Qi
[1
]
Jiang, Nan
[1
]
Li, Wenbang
[1
]
Chen, Li
[1
]
Lin, Xucong
[2
]
Xie, Zenghong
[2
]
You, Lijun
[1
]
Zhang, Qiqing
[1
,3
,4
]
机构:
[1] Fuzhou Univ, Inst Biomed & Pharmaceut Technol, Fuzhou 350002, Peoples R China
[2] Fuzhou Univ, Inst Food Safety & Environm Monitoring, Fuzhou 350108, Peoples R China
[3] Chinese Acad Med Sci, Inst Biomed Engn, Key Lab Biomed Mat Tianjin, Tianjin 300192, Peoples R China
[4] Peking Union Med Coll, Tianjin 300192, Peoples R China
基金:
中国国家自然科学基金;
关键词:
Aminoglycosides;
Evaporative light scattering detector;
Hydrophilic interaction;
In-tube solid-phase microextraction;
Urea-formaldehyde monolithic column;
TANDEM-MASS-SPECTROMETRY;
PERFORMANCE LIQUID-CHROMATOGRAPHY;
LIGHT-SCATTERING DETECTION;
ORGANIC POLYMER MONOLITHS;
CAPILLARY-ELECTROPHORESIS;
FLUORESCENCE DETECTION;
ANIMAL ORIGIN;
EXTRACTION;
RESIDUES;
HPLC;
D O I:
10.1016/j.Chroma.2017.01.027
中图分类号:
Q5 [生物化学];
学科分类号:
071010 ;
081704 ;
摘要:
A novel urea-formaldehyde (UF) monolithic column has been developed and exploited as a sorbent for hydrophilic in-tube solid-phase microextraction (in-tube SPME) of aminoglycosides (AGs). Because of the innate hydrophilicity, UF monolith showed high extraction efficiency towards these hydrophilic analytes. The adsorption capacities for target compounds dissolved in water/ACN (1:1, v/v) were in the range of 5.18-7.36 mu g/cm. Due to the lack of a chromophore, evaporative light scattering detector (ELSD) was selected as the detector for AGs, and coupled with the online in-tube SPME-HPLC system. Several factors of the online system, such as trifluoroacetic acid (TFA) and ACN percentage in the sampling solution, ionic strength in the sample solution, elution volume, sampling and elution flow rate, were optimized with respect to the extraction efficiencies. Under the optimized conditions, the limits of detection (LODs) of streptomycin, tobramycin and neomycin were discovered in the range of 3.0-5.2 mu g/kg. The recoveries were ranged from 82.1 to 96.7% with relative standard deviations (RSDs) of 2.3-5.1% (n =4) at spiking levels of 50, 200 and 500 mu g/kg, respectively. The excellent applicability of the UF monolithic column was examined by the determination of streptomycin in practical tilapia samples, which showed the potential advantages for the analysis of polar analytes in complicated samples. (C) 2017 Elsevier B.V. All rights reserved.