Failure analysis of the conical press-fit connections in a locomotive drive system

被引:3
|
作者
Shen, Longjiang [1 ,2 ,3 ]
Tang, Yingwu [3 ]
Jiang, Bingyan [1 ]
机构
[1] Cent S Univ, Coll Mech & Elect Engn, State Key Lab High Performance Complex Mfg, Changsha 410083, Hunan, Peoples R China
[2] CSR Zhuzhou Elect Locomot Co Ltd, Zhuzhou 412001, Peoples R China
[3] CSR Zhuzhou Elect Co Ltd, Zhuzhou 412001, Peoples R China
关键词
Failure analysis; Conical press-fit connections; Fretting wear/fatigue; Corrosion; Oil groove;
D O I
10.1016/j.engfailanal.2014.04.019
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
The nose-suspension drive designs with overhanging pinion are commonly applied in freight electrical locomotives because of simple, space-saving and cost-effective. The failures of conical press-fit connections in a nose-suspension drive system are analyzed in this paper. It was showed by the analysis that the crack on the inner conical surface of motor shaft is initiated by the combination of fretting and corrosion. Sharp oil groove edge and emergency of crack at the mouth of radial oil hole in pinion will accelerate the formation of fretting wear groove, and consequently the initiation of cracks. Coexist of tensile normal stress under the contact surface within the fretting zone will benefit the propagation of the fretting fatigue cracks. (C) 2014 Elsevier Ltd. All rights reserved.
引用
收藏
页码:158 / 167
页数:10
相关论文
共 50 条
  • [41] Patellar tendon anterior cruciate ligament reconstruction with conical press-fit femoral fixation: 5-year results in athletes population
    Gobbi, A
    Diara, A
    Mahajan, S
    Zanazzo, M
    Tuy, B
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2002, 10 (02) : 73 - 79
  • [42] Ergonomic Analysis of a Fuse Insertion, Press-fit and Test Workstation Using EWA Method - Ergonomic Workplace Analysis
    Bastos Nuno
    Gomez, Adriana
    Mesquita, Catarina
    Oliveira, Maria
    Pacheco, Tiago
    Pinheiro, Ivo
    Rodrigues, Beatriz
    Serra, Claudia
    Silva, Ana
    Sobral, Nuno
    Carneiro, Paula
    Colim, Ana
    SHO2019: INTERNATIONAL SYMPOSIUM ON OCCUPATIONAL SAFETY AND HYGIENE, 2019, : 222 - 225
  • [43] Nonlinear Dynamic Modeling and Resonance Analysis for Locomotive Drive System
    Wang, Chun-Sheng
    Liu, Chen
    Mao, Hong-Jun
    Liu, Zi-Jian
    INTERNATIONAL CONFERENCE ON MECHANICS, BUILDING MATERIAL AND CIVIL ENGINEERING (MBMCE 2015), 2015, : 230 - 235
  • [44] Early radiological and functional outcomes for a cementless press-fit design modular femoral stem revision system
    Hancock, Douglas S.
    Sharplin, Paul K.
    Larsen, Peter D.
    Phillips, Fredrick T. S.
    HIP INTERNATIONAL, 2019, 29 (01) : 35 - 40
  • [45] Press-fit fixation in anterior cruciate ligament reconstruction yields low graft failure and revision rates: a systematic review and meta-analysis
    Shanmugaraj, Ajaykumar
    Mahendralingam, Mathepan
    Gohal, Chetan
    Horner, Nolan
    Simunovic, Nicole
    Musahl, Volker
    Samuelsson, Kristian
    Ayeni, Olufemi R.
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2021, 29 (06) : 1750 - 1759
  • [46] Press-fit fixation in anterior cruciate ligament reconstruction yields low graft failure and revision rates: a systematic review and meta-analysis
    Ajaykumar Shanmugaraj
    Mathepan Mahendralingam
    Chetan Gohal
    Nolan Horner
    Nicole Simunovic
    Volker Musahl
    Kristian Samuelsson
    Olufemi R. Ayeni
    Knee Surgery, Sports Traumatology, Arthroscopy, 2021, 29 : 1750 - 1759
  • [47] Overview of the Geometric Parameters of a Press-Fit Interlocking Mechanism: Experimental and FEA Analysis of Steel Pipe Joint
    Campos, Urso
    Hall, David
    Matthews, John
    Morgan, Christopher
    Alam, Shaurav
    Baghi, Hadi
    PIPELINES 2018: PLANNING AND DESIGN, 2018, : 406 - 414
  • [48] Characterization of bone-implant fixation using modal analysis: Application to a press-fit implant model
    Swider, P.
    Guerin, G.
    Baas, Joergen
    Soballe, Kjeld
    Bechtold, Joan E.
    JOURNAL OF BIOMECHANICS, 2009, 42 (11) : 1643 - 1649
  • [49] Response to La Banca et al regarding "On the concerning early failure of a short stem press-fit humeral component"
    Nicholson, Gregory
    Pourzal, Robin
    Garrigues, Grant E.
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 2025, 34 (03) : e178 - e178
  • [50] Early failure of smooth hydroxyapatite-coated press-fit acetabular cup - 7 years of follow-up
    Cheung, KW
    Yung, SH
    Wong, KC
    Chiu, KH
    JOURNAL OF ARTHROPLASTY, 2005, 20 (05): : 627 - 631