Ergonomic Analysis of a Fuse Insertion, Press-fit and Test Workstation Using EWA Method - Ergonomic Workplace Analysis

被引:0
|
作者
Bastos Nuno [1 ]
Gomez, Adriana [1 ]
Mesquita, Catarina [1 ]
Oliveira, Maria [1 ]
Pacheco, Tiago [1 ]
Pinheiro, Ivo [1 ]
Rodrigues, Beatriz [1 ]
Serra, Claudia [1 ]
Silva, Ana [1 ]
Sobral, Nuno [1 ]
Carneiro, Paula [2 ]
Colim, Ana [2 ]
机构
[1] Univ Minho, Integrated Master Ind Engn & Management, Braga, Portugal
[2] Univ Minho, ALGORITMI Ctr, Braga, Portugal
关键词
Ergonomics; EWA; Lighting; Automobile company; Industrial Engineering;
D O I
暂无
中图分类号
R1 [预防医学、卫生学];
学科分类号
1004 ; 120402 ;
摘要
In recent times, more and more focus has been placed on workers' well-being, as they are an integral part of an organization This study was made in an automobile component company where a workstation, in the Built-in System Interface (BSI) area, was evaluated through the Ergonomic Workspace Analysis (EWA) method. The objective of this study was to evaluate the working conditions of the workers, in order to identify which factors are the most probable causes of discomfort. This method considers the perspective of the analyst, obtained by systematic observations on the workstation and the perspective of the workers achieved through questionnaires made to four workers. For the application of the method, it was necessary to collect quantitative data regarding the items Lighting, Thermal environment and Noise. After applying the method, the authors analysed the results and concluded that there are 3 factors that stand out from the others, these being the repetitiveness of work, lighting and thermal environment. In order to evaluate the severity of the critical items identified, it is proposed to apply other more specific analysis tools for the study, since the method is a generalist ergonomic analysis that allows a first evaluation of all the factors that can affect the employees but does not encompass further improvements for the problems encountered.
引用
收藏
页码:222 / 225
页数:4
相关论文
共 20 条
  • [1] Ergonomic workplace analysis (EWA)
    Sharan, Deepak
    WORK-A JOURNAL OF PREVENTION ASSESSMENT & REHABILITATION, 2012, 41 : 5366 - 5368
  • [2] Development of a Virtual Fit Analysis Method for an Ergonomic Design of Pilot Oxygen Mask
    Lee, Wonsup
    Jung, Daehan
    Park, Seikwon
    Kim, Heeeun
    You, Heecheon
    APPLIED SCIENCES-BASEL, 2021, 11 (12):
  • [3] A novel minimally invasive and press-fit method for symphysiodesis — a biomechanical analysis
    Tobias Fritz
    Marcel Orth
    Sascha J. Hopp
    Jeremy Briem
    Jill Hahner
    David Osche
    Tim Pohlemann
    Antonius Pizanis
    Journal of Experimental Orthopaedics, 10
  • [4] A novel minimally invasive and press-fit method for symphysiodesis - a biomechanical analysis
    Fritz, Tobias
    Orth, Marcel
    Hopp, Sascha J.
    Briem, Jeremy
    Hahner, Jill
    Osche, David
    Pohlemann, Tim
    Pizanis, Antonius
    JOURNAL OF EXPERIMENTAL ORTHOPAEDICS, 2023, 10 (01)
  • [5] ERGONOMIC ANALYSIS OF OPHTHALMIC NURSE WORKPLACE USING 3D SIMULATION
    Herzog, Vujica N.
    Beharic, Vujica R.
    Beharic, A.
    Buchmeister, B.
    INTERNATIONAL JOURNAL OF SIMULATION MODELLING, 2014, 13 (04) : 409 - 418
  • [6] Using Bibliometric Analysis, Ergonomic Principles and a Perching Stool to Prevent Injuries in the Workplace
    Asokan, Sachin
    Duffy, Vincent G.
    HCI INTERNATIONAL 2022 - LATE BREAKING PAPERS: ERGONOMICS AND PRODUCT DESIGN, HCII 2022, 2022, 13522 : 23 - 33
  • [7] Design Improvement of Assembly Workplace through Ergonomic Simulation and Analysis using DELMIA
    Usman, Shaban
    Zhu Haitao
    Ul Haq, Mazhar
    INTERNATIONAL JOURNAL OF ENGINEERING RESEARCH IN AFRICA, 2016, 21 : 238 - 246
  • [8] Biomechanical analysis of the press-fit effect in a conical Morse taper implant system by using an in vitro experimental test and finite element analysis
    Chang, Hung-Chih
    Chang, Chih-Han
    Li, Hung-Yuan
    Wang, Chau-Hsiang
    JOURNAL OF PROSTHETIC DENTISTRY, 2022, 127 (04): : 601 - 608
  • [9] Experimental analysis of insertion torques and forces of threaded and press-fit acetabular cups by means of ex vivo and in vivo measurements
    Vogel, Danny
    Rathay, Andreas
    Teufel, Stephanie
    Ellenrieder, Martin
    Zietz, Carmen
    Sander, Manuela
    Bader, Rainer
    ACTA OF BIOENGINEERING AND BIOMECHANICS, 2017, 19 (03) : 155 - 163
  • [10] Characterization of bone-implant fixation using modal analysis: Application to a press-fit implant model
    Swider, P.
    Guerin, G.
    Baas, Joergen
    Soballe, Kjeld
    Bechtold, Joan E.
    JOURNAL OF BIOMECHANICS, 2009, 42 (11) : 1643 - 1649