An 11-year retrospective study of totally implanted central venous access ports: Complications and patient satisfaction

被引:94
|
作者
Ignatov, A.
Hoffman, O.
Smith, B.
Fahlke, J. [2 ]
Peters, B. [3 ]
Bischoff, J.
Costa, S. -D. [1 ]
机构
[1] Otto Von Guericke Univ, Womens Clin, Dept Obstet & Gynecol, D-39108 Magdeburg, Germany
[2] Otto VonGuericke Univ Magdegurg, Dept Gen Visceral & Vasc Surg, D-39016 Magdeburg, Germany
[3] Otto VonGuericke Univ Magdegurg, Dept Biometr, D-39016 Magdeburg, Germany
来源
EJSO | 2009年 / 35卷 / 03期
关键词
Totally implanted access ports; TIAP; Central venous access ports; Catheters; Venous access devices; ATRIAL CATHETER; CHEMOTHERAPY; EXPERIENCE; DEVICES; SYSTEM; COSTS;
D O I
10.1016/j.ejso.2008.01.020
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Aims: We wanted to assess the factors that predict complications and patient satisfaction of totally implanted central venous access ports (TIAP). Methods: We reviewed 550 patients with breast or gynaecological malignancies who had initial port placement for chemotherapy between 1995 and 2006. We retrospectively assessed all TIAP complications, port duration and follow-up care until the TIAPs were removed (or the last known recorded documentation) or until the death of the patient. TIAP-related patient satisfaction was also assessed via a questionnaire-based survey of 356 patients. Results: 561 TIAPs were placed in 550 cancer patients (11 patients received 2 TIAPs during the study period); the median time of port duration was 22.5 months. There were 104 complications in this group. Of these, 81 occurred during chemotherapy treatment that lasted a median time of 182 days. Removal secondary to complication was observed in 48 cases. TIAPs placed on the left chest side, through the subclavian vein or with the catheter tip localized in the peripheral part of superior vena cava demonstrated the highest incidence of complications. Patients with a BMI >28.75 had an increased risk for developing complications. Our follow-up questionnaire revealed a 93% patient satisfaction rate with the TIAP. Conclusions: Patients with left-sided ports, catheter tips lying in the upper part of the superior vena Cava and implantation via the subclavian vein are at a higher risk for TIAP-associated complications. Being excessively overweight was assessed as another risk factor for developing complications. TIAPs are highly accepted and further recommended by patients. (C) 2008 Elsevier Ltd. All rights reserved.
引用
收藏
页码:241 / 246
页数:6
相关论文
共 50 条
  • [41] Totally implantable venous access ports: frequency of complications and analysis of bacterial contamination after ablation
    Barbut, F
    Soukouna, S
    Lalande, V
    Garcia, ML
    Neyme, D
    de Gramont, A
    Petit, JC
    PATHOLOGIE BIOLOGIE, 2004, 52 (10): : 566 - 574
  • [42] Follow-Up of Radiologically Totally Implanted Central Venous Access Ports of the Upper Arm: Long-Term Complications in 127,750 Catheter-Days
    Busch, Jasmin D.
    Herrmann, Jochen
    Heller, Friederike
    Derlin, Thorsten
    Koops, Andreas
    Adam, Gerhard
    Habermann, Christian R.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2012, 199 (02) : 447 - 452
  • [43] SATISFACTION OF PAEDIATRIC ONCOLOGY PATIENTS, SURVIVORS AND NURSES WITH THE LOCATION OF TOTALLY IMPLANTABLE VENOUS ACCESS PORTS (SPACE-STUDY)
    Van den Bosch, Ceder
    Van de Ven, Cornelus
    Hulsker, Caroline
    Bokkerink, Guus
    Van Scheltinga, Sheila Terwisscha
    De Wetering, Marianne
    Koopman, Maria
    Van der Pal, Heleen
    Wijnen, Marc
    Van der Steeg, Alida
    PEDIATRIC BLOOD & CANCER, 2023, 70 : S63 - S64
  • [44] Accuracy of totally implanted ports, tunnelled, single- and multiple-lumen central venous catheters for measurement of central venous pressure
    François Blot
    Agnès Laplanche
    Bruno Raynard
    Nathalie Germann
    Sami Antoun
    Gérard Nitenberg
    Intensive Care Medicine, 2000, 26 : 1837 - 1842
  • [45] Accuracy of totally implanted ports, tunnelled, single- and multiple-lumen central venous catheters for measurement of central venous pressure
    Blot, F
    Laplanche, A
    INTENSIVE CARE MEDICINE, 2000, 26 (12) : 1837 - 1842
  • [46] Hypospadias reconstruction: 11-year follow-up study of outcomes and patient satisfaction
    Harb A.
    Page F.
    Nassimizadeh M.
    Park A.
    European Journal of Plastic Surgery, 2017, 40 (1) : 23 - 28
  • [47] Thrombotic complications of implanted central venous access devices: prospective evaluation
    Labourey, JL
    Lacroix, P
    Genet, D
    Gobeaux, F
    Martin, J
    Venat-Bouvet, L
    Lavau-Denes, S
    Maubon, A
    Tubiana-Mathieu, N
    BULLETIN DU CANCER, 2004, 91 (05) : 431 - 436
  • [48] A cross-section questionnaire to evaluate patients' satisfaction with totally implanted access ports and retrospective analysis of port-related complications in a tertiary medical care center in Austria, an update
    Minichsdorfer, C.
    Berghoff, A. S.
    Fuereder, T.
    Maehr, B.
    Dressler, C.
    Gnant, M.
    Zielinski, C.
    Bartsch, R.
    ONKOLOGIE, 2013, 36 : 163 - 163
  • [49] Comparison of peripherally inserted central catheters and totally implanted venous access devices as chemotherapy delivery routes in oncology patients: A retrospective cohort study
    Yun, Woo-Sung
    Yang, Shin-Seok
    SCIENCE PROGRESS, 2021, 104 (02) : 1 - 12
  • [50] Complications associated with totally implantable access ports in children less than 1 year of age
    Ross, Aaron B.
    Rouanet, Eva
    Murphy, Andrew J.
    Weldon, Christopher B.
    Weil, Brent R.
    JOURNAL OF PEDIATRIC SURGERY, 2022, 57 (10) : 463 - 468