Reactive Power Compensation for Low Voltage ride-through of DFIG Wind Power System Based on SVC

被引:0
|
作者
Feng, Peng [1 ]
Xie, Chen [1 ]
机构
[1] Hefei Univ Technol, Sch Elect Engn & Automat, Hefei 230009, Peoples R China
关键词
SVC; Wind farm; Low voltage ride-through; Reactive power compensation;
D O I
10.23919/chicc.2019.8865982
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
During the grid fault, the DFIG low voltage ride-through guidelines require the wind farm to output the specified reactive current to support the electric grid voltage recovery, and the problem of the rotor overcurrent during fault will seriously damage the inverter. This paper proposed SVC to provide reactive power support and a control strategy to suppress the overcurrent, and builds a simulation model in MATLAB/Simulinlc.
引用
收藏
页码:6464 / 6469
页数:6
相关论文
共 50 条
  • [41] Low voltage ride-through capability improvement of DFIG-based wind turbines under unbalanced voltage dips
    Rahimi, Mohsen
    Parniani, Mostafa
    INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2014, 60 : 82 - 95
  • [42] Pitch Angle Control for Improving the Low Voltage Ride-Through Based on DFIG
    Li, Ruming
    Liu, Tianyu
    Zhu, Qinghua
    Zhang, Li
    COMPUTATIONAL INTELLIGENCE, NETWORKED SYSTEMS AND THEIR APPLICATIONS, 2014, 462 : 370 - 376
  • [43] Pitch angle control for improving the low voltage ride-through based on DFIG
    Li, Ruming
    Liu, Tianyu
    Zhu, Qinghua
    Zhang, Li
    Communications in Computer and Information Science, 2014, 462 : 370 - 376
  • [44] Overview of the Low Voltage Ride-through Technology for Direct-drive Permanent Magnetic wind Power System
    Huo Xin-zhang
    Xiao Xiang-ning
    MANUFACTURING SCIENCE AND TECHNOLOGY, PTS 1-8, 2012, 383-390 : 424 - 429
  • [45] Low Voltage Ride-through in DFIG Wind Generators by Controlling the Rotor Current without Crowbars
    Rodriguez Arribas, Jaime
    Fernandez Rodriguez, Adrian
    Hermoso Munoz, Angel
    Veganzones Nicolas, Carlos
    ENERGIES, 2014, 7 (02): : 498 - 519
  • [46] Low voltage ride-through improvement for fixed-speed wind turbines based on full power converters
    Huang, W. (hwhuang@mail.iee.ac.cn), 2013, Automation of Electric Power Systems Press (37):
  • [47] Influence of Large Area Wind Power Low Voltage Ride-through on Power Grid Frequency Caused by Power Grid Faults
    Liu Y.
    Wang C.
    Xia D.
    Xiao Y.
    Jin M.
    Feng W.
    Wang, Congying (wangocngying_7@163.com), 1600, Power System Technology Press (45): : 3505 - 3513
  • [48] Fast Coordinated Control of DFIG Wind Turbine Generators for Low and High Voltage Ride-Through
    Wang, Yun
    Wu, Qiuwei
    Xu, Honghua
    Guo, Qinglai
    Sun, Hongbin
    ENERGIES, 2014, 7 (07): : 4140 - 4156
  • [49] Research on Wind Power Generation Low Voltage Ride-through Protection Circuit Based on Energy Storage Component
    Xiao Wenjuan
    Ma Xiaoqin
    2019 IEEE 2ND INTERNATIONAL CONFERENCE ON INFORMATION AND COMPUTER TECHNOLOGIES (ICICT), 2019, : 270 - 274
  • [50] Enhancement of demagnetization control for low-voltage ride-through capability in DFIG-based wind farm
    M. Kenan Döşoğlu
    Uğur Güvenç
    Yusuf Sönmez
    Cemal Yılmaz
    Electrical Engineering, 2018, 100 : 491 - 498