Reactive Power Compensation for Low Voltage ride-through of DFIG Wind Power System Based on SVC

被引:0
|
作者
Feng, Peng [1 ]
Xie, Chen [1 ]
机构
[1] Hefei Univ Technol, Sch Elect Engn & Automat, Hefei 230009, Peoples R China
关键词
SVC; Wind farm; Low voltage ride-through; Reactive power compensation;
D O I
10.23919/chicc.2019.8865982
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
During the grid fault, the DFIG low voltage ride-through guidelines require the wind farm to output the specified reactive current to support the electric grid voltage recovery, and the problem of the rotor overcurrent during fault will seriously damage the inverter. This paper proposed SVC to provide reactive power support and a control strategy to suppress the overcurrent, and builds a simulation model in MATLAB/Simulinlc.
引用
收藏
页码:6464 / 6469
页数:6
相关论文
共 50 条
  • [31] An integrated reactive power control strategy for improving low voltage ride-through capability
    Gatavi E.
    Hellany A.
    Nagrial M.
    Rizk J.
    Chinese J. Electr. Eng., 4 (1-14): : 1 - 14
  • [32] Research on Low Voltage Ride-through Technique in DD-PMSG Wind Power Generator System
    Li Yinxing
    Liu Penghui
    Zhang Junli
    MECHATRONICS AND APPLIED MECHANICS II, PTS 1 AND 2, 2013, 300-301 : 108 - 111
  • [33] Research on reactive power control and the low-voltage ride-through capability of PMSG
    Liu, Sheng-Wen
    Bao, Guang-Qing
    Fan, Shao-Wei
    Dianli Xitong Baohu yu Kongzhi/Power System Protection and Control, 2012, 40 (02): : 135 - 140
  • [34] A reactive power control strategy in low-voltage ride-through of photovoltaic generation system based on MPPT mode
    Xie, Jiqiang
    Yang, Xiu
    Wang, Jubo
    Taiyangneng Xuebao/Acta Energiae Solaris Sinica, 2019, 40 (12): : 2426 - 3434
  • [35] Direct Transient Control of Wind Turbine Driven DFIG for Low Voltage Ride-Through
    Liang, Jiaqi
    Qiao, Wei
    Harley, Ronald G.
    2009 IEEE POWER ELECTRONICS AND MACHINES IN WIND APPLICATIONS, 2009, : 89 - +
  • [36] Low voltage ride-through capability of doubly fed wind power generators based on crowbar circuit
    Zhou, Zhiyu
    Guo, Yufeng
    Harbin Gongye Daxue Xuebao/Journal of Harbin Institute of Technology, 2013, 45 (04): : 122 - 128
  • [37] Low Voltage Ride-through Control Strategy for DFIG-based Wind Turbine Based on Disturbance Attenuation
    Zhang R.
    Qin B.
    Li H.
    Liu W.
    Chen J.
    Qin, Boyu (qinboyu@xjtu.edu.cn), 1600, Automation of Electric Power Systems Press (44): : 112 - 120
  • [38] Line-Fault Ride-Through (LFRT) Capabilities of DFIG Wind Turbine Connected to the Power System
    Khattara, A.
    Bahri, M.
    Aboubou, A.
    Becherif, M.
    Ayad, M. Y.
    3RD INTERNATIONAL CONFERENCE ON BIOMEDICAL ENGINEERING AND TECHNOLOGY - ICBET 2013, 2013, 7 : 189 - 194
  • [39] Zero-Voltage Ride-Through Scheme of PMSG Wind Power System Based on NLESO and GFTSMC
    Kang, Zhongjian
    Li, Jinfeng
    ELECTRONICS, 2023, 12 (20)
  • [40] Low Voltage Ride-Through Capability Improvement of Wind Power Generation Using Dynamic Voltage Restorer
    Hasegawa, Naohiro
    Kumano, Teruiiisa
    RECENT ADVANCES IN ENERGY AND ENVIRONMENT, 2010, : 166 - +