Development of a scanning tunneling microscope for variable temperature electron spin resonance

被引:17
|
作者
Hwang, Jiyoon [1 ,2 ]
Krylov, Denis [1 ,3 ]
Elbertse, Robbie [4 ]
Yoon, Sangwon [1 ,3 ]
Ahn, Taehong [1 ,2 ]
Oh, Jeongmin [1 ,2 ]
Fang, Lei [1 ,3 ]
Jang, Won-jun [5 ]
Cho, Franklin. H. H. [1 ,3 ]
Heinrich, Andreas. J. J. [1 ,2 ]
Bae, Yujeong [1 ,2 ]
机构
[1] Inst for Basic Sci Korea, Ctr Quantum Nanosci, Seoul 03760, South Korea
[2] Ewha Womans Univ, Dept Phys, Seoul 03760, South Korea
[3] Ewha Womans Univ, Seoul 03760, South Korea
[4] Delft Univ Technol, Kavli Inst Nanosci, Dept Quantum Nanosci, Lorentzweg 1, NL-2628 CJ Delft, Netherlands
[5] Samsung Adv Inst Technol, Suwon 13595, South Korea
来源
REVIEW OF SCIENTIFIC INSTRUMENTS | 2022年 / 93卷 / 09期
关键词
INDIVIDUAL ATOMS; SINGLE;
D O I
10.1063/5.0096081
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Recent advances in improving the spectroscopic energy resolution in scanning tunneling microscopy (STM) have been achieved by integrating electron spin resonance (ESR) with STM. Here, we demonstrate the design and performance of a homebuilt STM capable of ESR at temperatures ranging from 1 to 10 K. The STM is incorporated with a homebuilt Joule-Thomson refrigerator and a two-axis vector magnet. Our STM design allows for the deposition of atoms and molecules directly into the cold STM, eliminating the need to extract the sample for deposition. In addition, we adopt two methods to apply radio-frequency (RF) voltages to the tunnel junction: the early design of wiring to the STM tip directly and a more recent idea to use an RF antenna. Direct comparisons of ESR results measured using the two methods and simulations of electric field distribution around the tunnel junction show that, despite their different designs and capacitive coupling to the tunnel junction, there is no discernible difference in the driving and detection of ESR. Furthermore, at a magnetic field of similar to 1.6 T, we observe ESR signals (near 40 GHz) sustained up to 10 K, which is the highest temperature for ESR-STM measurement reported to date, to the best of our knowledge. Although the ESR intensity exponentially decreases with increasing temperature, our ESR-STM system with low noise at the tunnel junction allows us to measure weak ESR signals with intensities of a few fA. Our new design of an ESR-STM system, which is operational in a large frequency and temperature range, can broaden the use of ESR spectroscopy in STM and enable the simple modification of existing STM systems, which will hopefully accelerate a generalized use of ESR-STM.
引用
收藏
页数:12
相关论文
共 50 条
  • [1] Upgrade of a low-temperature scanning tunneling microscope for electron-spin resonance
    Natterer, Fabian D.
    Patthey, Francois
    Bilgeri, Tobias
    Forrester, Patrick R.
    Weiss, Nicolas
    Brune, Harald
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2019, 90 (01):
  • [2] VARIABLE-TEMPERATURE SCANNING TUNNELING MICROSCOPE
    LYDING, JW
    SKALA, S
    HUBACEK, JS
    BROCKENBROUGH, R
    GAMMIE, G
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1988, 59 (09): : 1897 - 1902
  • [3] THEORY OF ELECTRON-SPIN-RESONANCE TOPOGRAPHY OF SURFACES BY THE SCANNING TUNNELING MICROSCOPE
    MOLOTKOV, SN
    SURFACE SCIENCE, 1994, 302 (1-2) : 235 - 240
  • [4] SIMPLE, VARIABLE-TEMPERATURE, SCANNING TUNNELING MICROSCOPE
    DUBSON, MA
    HWANG, JS
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1992, 63 (07): : 3643 - 3645
  • [5] ELECTRON-PARAMAGNETIC RESONANCE IN A SCANNING TUNNELING MICROSCOPE
    MOLOTKOV, SN
    JETP LETTERS, 1992, 55 (10) : 593 - 597
  • [6] Spin-polarized electron tunneling detected using a scanning tunneling microscope
    Wu, ZH
    Nakayama, T
    Sakurai, M
    Aono, M
    SURFACE SCIENCE, 1997, 386 (1-3) : 311 - 314
  • [7] A variable-temperature ultrahigh vacuum scanning tunneling microscope
    Zhang, H
    Memmert, U
    Houbertz, R
    Hartmann, U
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2001, 72 (06): : 2613 - 2617
  • [8] DESIGN PRINCIPLES OF A VARIABLE-TEMPERATURE SCANNING TUNNELING MICROSCOPE
    BOTT, M
    MICHELY, T
    COMSA, G
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1995, 66 (08): : 4135 - 4139
  • [9] Cryogenic variable temperature ultrahigh vacuum scanning tunneling microscope
    Foley, ET
    Kam, AF
    Lyding, JW
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2000, 71 (09): : 3428 - 3435
  • [10] Longitudinal and transverse electron paramagnetic resonance in a scanning tunneling microscope
    Seifert, Tom S.
    Kovarik, Stepan
    Juraschek, Dominik M.
    Spaldin, Nicola A.
    Gambardella, Pietro
    Stepanow, Sebastian
    SCIENCE ADVANCES, 2020, 6 (40)