The initial stability of the cementless acetabular cup significantly affects the outcome of surgery for total hip replacement. Although it is essential to minimize the relative displacement between the pelvis and metal, few previous studies have addressed this issue. This study investigated the effects of varying the sizes of acetabular components on the stability. Eighty-one finite element models of total acetabular replacements with various configurations were created in the finite element package ANSYS. The following three size parameters and one fixation parameter were investigated: femoral head diameter (26, 28, and 30 mm), polyethylene liner thickness (9, 10, and 11 mm), metal cup thickness (2, 3, and 4 mm), and number of fixation screws (one, two, and three). In all of these models, one-leg stance loading was applied at the center of the femoral head, and the boundary condition consisted of immobile screw holes. The peak displacement at the cup exterior surface was used to evaluate the stability. The simulations indicated that the peak displacement was decreased by increasing the cup thickness, decreasing the polyethylene liner, and decreasing the femoral head size. The mechanisms affecting the stability were the structural stiffness and moment arm (effect distance between the loaded head center and the fixation screws). Increasing the cup thickness had a major impact on the structural stiffness and a minor effect on the moment arm, thereby decreasing the cup displacement. On the other hand increasing the head size or linear thickness had a larger impact on moment arm and a smaller effect on structural stiffness, thereby increasing the cup displacement. Among these three factors, the cup thickness had the greatest impact. Further, increasing the number of screws could enhance cup stability, and extra screws might be needed to ensure adequate stability of a thin cup.
引用
收藏
页码:59 / 63
页数:5
相关论文
共 50 条
  • [31] Finite Element Analysis of the Impingement on the Acetabular Liner Rim due to Wear of the Acetabular Liner Surface
    Saputra, Eko
    Anwar, Iwan Budiwan
    Ismail, Rifky
    Jamari, J.
    van der Heide, Emile
    [J]. 3RD INTERNATIONAL CONFERENCE ON ADVANCED MATERIALS SCIENCE AND TECHNOLOGY (ICAMST 2015), 2016, 1725
  • [32] Analysis of Cementless Acetabular Cup Rotation
    McCartney, William T.
    Lostado-Lorza, Ruben
    Mac Donald, Bryan J.
    [J]. INTERNATIONAL JOURNAL OF APPLIED RESEARCH IN VETERINARY MEDICINE, 2015, 13 (02): : 122 - 124
  • [33] Is the construct stability of the acetabular cup affected by the acetabular screw configuration in bone defect models?
    Nam, Ho-Jin
    Lim, Young-Wook
    Jo, Woo-Lam
    Bahk, Ji Hoon
    Kwon, Soon-Yong
    Park, Hyung Chul
    AlShammari, Saad Mohammed
    [J]. JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2023, 18 (01)
  • [34] Calibration of crushable foam plasticity models for synthetic bone material for use in finite element analysis of acetabular cup deformation and primary stability
    Schulze, Christian
    Vogel, Danny
    Sander, Manuela
    Bader, Rainer
    [J]. COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING, 2019, 22 (01) : 25 - 37
  • [35] Is the construct stability of the acetabular cup affected by the acetabular screw configuration in bone defect models?
    Ho-Jin Nam
    Young-Wook Lim
    Woo-Lam Jo
    Ji Hoon Bahk
    Soon-Yong Kwon
    Hyung Chul Park
    Saad Mohammed AlShammari
    [J]. Journal of Orthopaedic Surgery and Research, 18
  • [36] Abductor weakness and stresses around acetabular components of total hip arthroplasty: a finite element analysis
    Sutherland, AG
    D'Arcy, S
    Smart, D
    Ashcroft, GP
    [J]. INTERNATIONAL ORTHOPAEDICS, 1999, 23 (05) : 275 - 278
  • [37] INITIAL MECHANICAL STABILITY OF ACETABULAR PROSTHESES
    LITSKY, AS
    POPHAL, SG
    [J]. ORTHOPEDICS, 1994, 17 (01) : 53 - 57
  • [38] The role of muscle forces and gait cycle discretization when assessing acetabular cup primary stability: A finite element study
    Fallahnezhad, Khosro
    O'Rourke, Dermot
    Bahl, Jasvir S.
    Thewlis, Dominic
    Taylor, Mark
    [J]. COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE, 2023, 230
  • [39] Abductor weakness and stresses around acetabular components of total hip arthroplasty: a finite element analysis
    A. G. Sutherland
    S. D’Arcy
    D Smart
    G. P. Ashcroft
    [J]. International Orthopaedics, 1999, 23 : 275 - 278
  • [40] Effects of Acetabular Screws on the Initial Stability of Porous Coated Acetabular Implants in Revision Total Hip Arthroplasty
    Kaplan, Nathan B.
    Barra, Matthew F.
    Jubril, Ayodeji
    Knapp, Emma
    Awad, Hani
    Ginnetti, John
    [J]. CUREUS JOURNAL OF MEDICAL SCIENCE, 2023, 15 (04)