Finite Element Analysis of the Effects of Sizes of Acetabular Components on the Initial Stability of the Acetabular Cup

被引:0
|
作者
Hsu, Jui-Ting [1 ]
Tsai, Ming-Tzu [2 ]
Chang, Chih-Han [3 ]
Fuh, Lih-Jyh [1 ]
Lai, Kuo-An [4 ]
Liu, Zi-Ling [3 ]
Tu, Ming-Gene [1 ]
Huang, Heng-Li [1 ]
机构
[1] China Med Univ, Sch Dent, Taichung 404, Taiwan
[2] Chung Yuan Christian Univ, Dept Biomed Engn, Chungli 320, Taiwan
[3] Natl Cheng Kung Univ, Inst Biomed Engn, Tainan 701, Taiwan
[4] Natl Cheng Kung Univ, Dept Orthopaed, Med Ctr, Tainan 701, Taiwan
关键词
Finite element simulation; Total hip replacement; Acetabular component; Initial stability; Size;
D O I
暂无
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The initial stability of the cementless acetabular cup significantly affects the outcome of surgery for total hip replacement. Although it is essential to minimize the relative displacement between the pelvis and metal, few previous studies have addressed this issue. This study investigated the effects of varying the sizes of acetabular components on the stability. Eighty-one finite element models of total acetabular replacements with various configurations were created in the finite element package ANSYS. The following three size parameters and one fixation parameter were investigated: femoral head diameter (26, 28, and 30 mm), polyethylene liner thickness (9, 10, and 11 mm), metal cup thickness (2, 3, and 4 mm), and number of fixation screws (one, two, and three). In all of these models, one-leg stance loading was applied at the center of the femoral head, and the boundary condition consisted of immobile screw holes. The peak displacement at the cup exterior surface was used to evaluate the stability. The simulations indicated that the peak displacement was decreased by increasing the cup thickness, decreasing the polyethylene liner, and decreasing the femoral head size. The mechanisms affecting the stability were the structural stiffness and moment arm (effect distance between the loaded head center and the fixation screws). Increasing the cup thickness had a major impact on the structural stiffness and a minor effect on the moment arm, thereby decreasing the cup displacement. On the other hand increasing the head size or linear thickness had a larger impact on moment arm and a smaller effect on structural stiffness, thereby increasing the cup displacement. Among these three factors, the cup thickness had the greatest impact. Further, increasing the number of screws could enhance cup stability, and extra screws might be needed to ensure adequate stability of a thin cup.
引用
收藏
页码:59 / 63
页数:5
相关论文
共 50 条
  • [21] In Vitro Evaluation of the Acetabular Cup Primary Stability by Impact Analysis
    Michel, Adrien
    Bosc, Romain
    Vayron, Romain
    Haiat, Guillaume
    [J]. JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2015, 137 (03):
  • [22] The effect of dorsal rim loss on the initial stability of the BioMedtrix cementless acetabular cup
    Montgomery, Meredith L.
    Kim, Stanley E.
    Dyce, Jonathan
    Pozzi, Antonio
    [J]. BMC VETERINARY RESEARCH, 2015, 11
  • [23] The effect of dorsal rim loss on the initial stability of the BioMedtrix cementless acetabular cup
    Meredith L Montgomery
    Stanley E Kim
    Jonathan Dyce
    Antonio Pozzi
    [J]. BMC Veterinary Research, 11
  • [24] Initial stability of a highly porous titanium cup in an acetabular bone defect model
    Yoshimoto, Kensei
    Nakashima, Yasuharu
    Wakiyama, Miyo
    Hara, Daisuke
    Nakamura, Akihiro
    Iwamoto, Mikio
    [J]. JOURNAL OF ORTHOPAEDIC SCIENCE, 2018, 23 (04) : 665 - 670
  • [25] Finite element analysis of posterior acetabular column plate and posterior acetabular wall prostheses in treating posterior acetabular fractures
    Guixiong Huang
    Yizhou Wan
    Kaifang Chen
    Zhenchun Yin
    Qinghua Song
    Yi Xu
    Xiaodong Guo
    [J]. Journal of Orthopaedic Surgery and Research, 18
  • [26] Finite element analysis of posterior acetabular column plate and posterior acetabular wall prostheses in treating posterior acetabular fractures
    Huang, Guixiong
    Wan, Yizhou
    Chen, Kaifang
    Yin, Zhenchun
    Song, Qinghua
    Xu, Yi
    Guo, Xiaodong
    [J]. JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2023, 18 (01)
  • [27] The effect of acetabular cup size on the short-term stability of revision hip arthroplasty: a finite element investigation
    Phillips, ATM
    Pankaj
    Usmani, AS
    Howie, CR
    [J]. PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2004, 218 (H4) : 239 - 249
  • [28] A parametric study of acetabular cup design variables using finite element analysis and statistical design of experiments
    Mantell, SC
    Chanda, H
    Bechtold, JE
    Kyle, RF
    [J]. JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 1998, 120 (05): : 667 - 675
  • [29] A parametric study of acetabular cup design variables using finite element analysis and statistical design of experiments
    Mantell, S.C.
    Chanda, H.
    Bechtold, J.E.
    Kyle, R.F.
    [J]. Journal of Biomechanical Engineering, 1998, 120 (05): : 667 - 675
  • [30] Initial stability of a cementless acetabular cup design: Experimental investigation on the effect of adding fins to the rim of the cup
    Baleani, M
    Fognani, R
    Toni, A
    [J]. ARTIFICIAL ORGANS, 2001, 25 (08) : 664 - 669