Effect on noise of intensity-axis correction of spectra recorded with charge-coupled device detectors

被引:5
|
作者
Jones, JP [1 ]
Wambles, RE [1 ]
Mann, CK [1 ]
Vickers, TJ [1 ]
机构
[1] Florida State Univ, Dept Chem & Biochem, Tallahassee, FL 32306 USA
关键词
charge-coupled device detectors; Raman spectroscopy; intensity-axis correction;
D O I
10.1366/0003702021955321
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
We have examined the effect of intensity-axis correction on noise in white light spectra recorded with charge-coupled device (CCD) detectors. Measurements were made with five detectors in Raman spectrometers. Detectors were both liquid-nitrogen and thermoelectrically cooled devices and one room temperature device. Both random and pattern noise have been considered. We used cross-correlation of noise sets to provide an indicator of a fixed pattern in the spectra and an assessment of the efficacy of the correction procedure in removing this pattern. For four of the five detectors intensity-axis correction provided a significant improvement in signal-to-noise ratio. Correction was particularly important for measurements made with lower-cost CCD detectors of the kind proposed for process control instruments.
引用
收藏
页码:564 / 569
页数:6
相关论文
共 50 条
  • [31] Charge-coupled device panoramic radiography: effect of beam energy on radiation exposure
    Farman, TT
    Farman, AG
    Kelly, MS
    Firriolo, FJ
    Yancey, JM
    Stewart, AV
    DENTOMAXILLOFACIAL RADIOLOGY, 1998, 27 (01) : 36 - 40
  • [32] SIGNAL-TO-NOISE RATIO AND LESION DETECTABILITY IN AN OPTICALLY COUPLED CHARGE-COUPLED DEVICE IMAGING-SYSTEM
    LIU, H
    KARELLAS, A
    MOORE, SC
    HARRIS, LJ
    RADIOLOGY, 1992, 185 : 202 - 202
  • [33] Improved charge-coupled device detectors for high-speed, charge exchange spectroscopy studies on the DIII-D tokamak
    Burrell, KH
    Gohil, P
    Groebner, RJ
    Kaplan, DH
    Robinson, JI
    Solomon, WM
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2004, 75 (10): : 3455 - 3457
  • [34] Study of afterglow in x-ray phosphors for use on fast-framing charge-coupled device detectors
    Shepherd, JA
    Gruner, SM
    Tate, MW
    Tecotzky, M
    OPTICAL ENGINEERING, 1997, 36 (11) : 3212 - 3222
  • [35] Achieving Sub-Shot-Noise Absorption-Spectroscopy with Avalanche Photodiodes and with a Charge-Coupled Device
    Sabines-Chesterking, Javier
    Whittaker, Rebecca
    Moreau, Paul-Antoine
    McMillan, Alex R.
    Joshi, Siddarth
    Prasannan, Nidhin
    Erven, Chris
    Neville, Alex
    Berry, Monica
    O'Brien, Jeremy L.
    Cable, Hugo V.
    Rarity, John G.
    Matthews, Jonathan C. F.
    2016 CONFERENCE ON LASERS AND ELECTRO-OPTICS (CLEO), 2016,
  • [36] INHERENT SIGNAL-TO-NOISE RATIO LIMITATIONS OF CHARGE-COUPLED DEVICE PSEUDONOISE MATCHED-FILTERS
    GRIECO, DM
    IEEE TRANSACTIONS ON COMMUNICATIONS, 1980, 28 (05) : 729 - 732
  • [37] Three-step nonuniformity correction for a highly dynamic intensified charge-coupled device star sensor
    Jin, Yan
    Jiang, Jie
    Zhang, Guangjun
    OPTICS COMMUNICATIONS, 2012, 285 (07) : 1753 - 1758
  • [38] Optimized algorithm for the spatial nonuniformity correction of an imaging system based on a charge-coupled device color camera
    de Lasarte, Marta
    Pujol, Jaume
    Arjona, Montserrat
    Vilaseca, Meritxell
    APPLIED OPTICS, 2007, 46 (02) : 167 - 174
  • [39] Relationship between the charge-coupled device signal-to-noise ratio and dynamic range with respect to the analog gain
    Wang, Dejiang
    Zhang, Tao
    Kuang, Haipeng
    APPLIED OPTICS, 2012, 51 (29) : 7103 - 7114
  • [40] Charge-coupled device camera optical density range enhancement and the effect on radiographic image segmentation
    Chester, EG
    Sharif, BS
    Owen, JP