Effect on noise of intensity-axis correction of spectra recorded with charge-coupled device detectors

被引:5
|
作者
Jones, JP [1 ]
Wambles, RE [1 ]
Mann, CK [1 ]
Vickers, TJ [1 ]
机构
[1] Florida State Univ, Dept Chem & Biochem, Tallahassee, FL 32306 USA
关键词
charge-coupled device detectors; Raman spectroscopy; intensity-axis correction;
D O I
10.1366/0003702021955321
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
We have examined the effect of intensity-axis correction on noise in white light spectra recorded with charge-coupled device (CCD) detectors. Measurements were made with five detectors in Raman spectrometers. Detectors were both liquid-nitrogen and thermoelectrically cooled devices and one room temperature device. Both random and pattern noise have been considered. We used cross-correlation of noise sets to provide an indicator of a fixed pattern in the spectra and an assessment of the efficacy of the correction procedure in removing this pattern. For four of the five detectors intensity-axis correction provided a significant improvement in signal-to-noise ratio. Correction was particularly important for measurements made with lower-cost CCD detectors of the kind proposed for process control instruments.
引用
收藏
页码:564 / 569
页数:6
相关论文
共 50 条
  • [21] CHARGE-COUPLED DEVICE PSEUDO-NOISE MATCHED-FILTER DESIGN
    MAGILL, EG
    GRIECO, DM
    DYCK, RH
    CHEN, PCY
    PROCEEDINGS OF THE IEEE, 1979, 67 (01) : 50 - 60
  • [22] Recent advances of short-pulse laser-induced breakdown effect on charge-coupled device detectors
    Li, Yunfei
    Kou, Zilong
    Wang, Gong
    Hou, Yachong
    Xie, Xiaofan
    Yu, Yu
    Wang, Yulei
    Lu, Zhiwei
    OPTICS AND LASER TECHNOLOGY, 2022, 156
  • [23] Data processing correction of the irising effect of a fast-gating intensified charge-coupled device on laser-pulse-excited luminescence spectra
    Ondic, L.
    Dohnalova, K.
    Pelant, I.
    Zidek, K.
    de Boer, W. D. A. M.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2010, 81 (06):
  • [24] Study on the mechanism of temperature effect on proton irradiated charge-coupled device
    Wen, Lin
    Zhao, Zitao
    Zhou, Dong
    Li, Yudong
    Feng, Jie
    Guo, Qi
    RADIATION EFFECTS AND DEFECTS IN SOLIDS, 2023, 178 (5-6): : 668 - 679
  • [25] The Hubble Space Telescope Wide Field Camera 3 instrument Charge-Coupled Device detectors
    Waczynski, A
    Beck, T
    Boucarut, R
    Cheng, E
    Cottingham, D
    Delo, G
    Fixsen, D
    Hill, RJ
    Johnson, S
    Kenny, P
    Landsman, W
    Malumuth, E
    Offenberg, J
    Polidan, E
    Russell, AM
    Schlossberg, D
    Sharp, E
    Wassell, E
    Wen, Y
    Yagelowich, J
    SCIENTIFIC DETECTORS FOR ASTRONOMY: THE BEGINNING OF A NEW ERA, 2004, 300 : 403 - 406
  • [26] Experimental method for the extraction of intensity profiles by imaging the scattered pattern with a charge-coupled device
    Li, Haixia
    Zhang, Meina
    Chen, Xiaoyi
    Liu, Chunxiang
    Cheng, Chuanfu
    CHINESE OPTICS LETTERS, 2012, 10 (05)
  • [27] ANALYTICAL NOISE PERFORMANCE MODELING OF DETECTOR CHARGE-COUPLED DEVICE (CCD) HYBRID DEVICES
    MCDONALD, WT
    HOWARTH, HC
    KLEINER, CT
    PROCEEDINGS OF THE SOCIETY OF PHOTO-OPTICAL INSTRUMENTATION ENGINEERS, 1982, 327 : 154 - 162
  • [28] Effect of the charge-coupled image device's non-uniformity by neutrons
    Xiao, Zhi-Gang
    Tang, Ben-Qi
    Li, Jun-Li
    Liu, Min-Bo
    Zhang, Yong
    Wang, Zu-Jun
    Huang, Shao-Yan
    Hedianzixue Yu Tance Jishu/Nuclear Electronics and Detection Technology, 2007, 27 (04): : 724 - 726
  • [29] Effect of the spectrometer slit width and charge-coupled device detector on Raman intensities
    Jakubek, Ryan S.
    JOURNAL OF RAMAN SPECTROSCOPY, 2021, 52 (07) : 1317 - 1333
  • [30] A method to improve the nonrepetitive acquisition of transient absorption spectra with an intensified charge-coupled device camera
    Baldacchino, G
    Hickel, B
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1998, 69 (04): : 1605 - 1609