Haemodynamic vector personalization of a quadripolar left ventricular lead used for cardiac resynchronization therapy: use of surface electrocardiogram and interventricular time delays

被引:7
|
作者
Trolese, Luca [1 ]
Biermann, Juergen [1 ]
Hartmann, Maximilian [1 ]
Schluermann, Fabienne [1 ]
Faber, Thomas S. [1 ]
Bode, Christoph [1 ]
Asbach, Stefan [1 ]
机构
[1] Univ Freiburg, Dept Cardiol & Angiol 1, Ctr Heart, D-79106 Freiburg, Germany
来源
EUROPACE | 2014年 / 16卷 / 10期
关键词
Cardiac resynchronization therapy; Quadripolar lead; Haemodynamics; QRS duration; Interventricular time delays; CHRONIC HEART-FAILURE; MULTICENTER; PARAMETERS; EXPERIENCE; DURATION;
D O I
10.1093/europace/euu136
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aims The choice of left ventricular pacing configurations (LVPCs) of quadripolar leads used for cardiac resynchronization therapy (CRT) affects haemodynamic response and thus may be a tool for device optimization. The value of surface electrocardiograms and interventricular time delays (IVDs) for optimization is unknown. Methods and results Sixteen patients implanted with a CRT device with a quadripolar LV lead underwent invasive testing of LV dP/dt. QRS durations at baseline (bl) and during biventricular pacing (biv) were measured using different LVPCs (total of 141 LVPCs; 8.8 per patient). Variations in QRS duration during biv were calculated for each patient (Delta QRS) and, when compared with intrinsic QRS duration, for all LVPCs (Delta QRS(LVPC)). Interventricular time delays between the poles of the LV lead were obtained from intracardiac electrograms. Delta IVD was calculated as IVDmax - IVDmin. Parameters were correlated with LV dP/dt. Delta QRS and Delta QRS(LVPC) both significantly correlated with LV dP/dt (P < 0.01). Correlation was found for patients with ischaemic (P < 0.001) and non-ischaemic cardiomyopathy (P < 0.05), and for patients with bl QRS duration >168 ms (P < 0.001), but not,168 ms (P = ns). The LVPC with shortest QRS duration also yielded maximal LV dP/dt in 6 of 16 patients (37.5%), and was equal or better in LV dP/dt in 12 of 16 patients (75%). Delta IVD neither correlated with Delta QRS nor Delta LV dP/dt. Conclusion Delta QRS predicts the maximal value of vector personalization in the individual. Reductions inQRS width, but not IVDs, correlate with acute haemodynamic response. Intraindividually, in 75% of patients, the LVPC with the shortest QRS duration gives equal or superior haemodynamic results when compared with the LVPC with longest QRS duration.
引用
收藏
页码:1476 / 1481
页数:6
相关论文
共 50 条
  • [41] Left ventricular lead placement in cardiac resynchronization therapy: where and how?
    Khan, Fakhar Zaman
    Virdee, Munmohan Singh
    Fynn, Simon Patrick
    Dutka, David Paul
    EUROPACE, 2009, 11 (05): : 554 - 561
  • [42] Snare system for left ventricular lead placement in cardiac resynchronization therapy
    Magalhaes, Andreia
    Menezes, Miguel
    Cortez-Dias, Nuno
    de Sousa, Joao
    Marques, Pedro
    REVISTA PORTUGUESA DE CARDIOLOGIA, 2015, 34 (03) : 219 - 220
  • [43] Influence of Left Ventricular Lead Site on the Response to Cardiac Resynchronization Therapy
    Camanho, Luiz E. M.
    Saad, Eduardo B.
    Slater, Charles
    Junior, Luiz Antonio O. I.
    Ladeira, Fernanda B.
    Dias, Lucas C.
    Rocha, Ricardo M.
    JOURNAL OF CARDIAC FAILURE, 2016, 22 (08) : S71 - S71
  • [44] Feasibility of left ventricular endocardial lead pacing for cardiac resynchronization therapy
    Algazzar, Alaa Solaiman
    Taha, Mohamed Osama
    Katta, Azza Ali
    El Abbady, Asmaa
    Lotfy, Heba Abdelmoteleb
    EGYPTIAN JOURNAL OF CRITICAL CARE MEDICINE, 2018, 6 (02): : 53 - 55
  • [45] Left ventricular lead positioning in cardiac resynchronization therapy: Mission accomplished?
    Nguyen, Uyen Chau
    Prinzen, Frits W.
    Vernooy, Kevin
    HEART RHYTHM, 2017, 14 (09) : 1373 - 1374
  • [46] Performance of a novel active fixation quadripolar left ventricular lead for cardiac resynchronization therapy: Attain Stability Quad Clinical Study results
    Jackson, Kevin P.
    Faeresstrand, Svein
    Philippon, Francois
    Yee, Raymond
    Kong, Melissa H.
    Kloppe, Axel
    Bongiorni, Maria Grazia
    Lee, Scott F.
    Canby, Robert C.
    Pouliot, Erika
    van Ginneken, Mireille M. E.
    Crossley, George H.
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2020, 31 (05) : 1147 - 1154
  • [47] The quest for an optimal left ventricular lead position for cardiac resynchronization therapy
    Burri, Haran
    HEART RHYTHM, 2006, 3 (11) : 1293 - 1294
  • [48] Experience with the use of a coronary balloon catheter for the implant of the left ventricular lead for cardiac resynchronization therapy
    Lainez, E. Arbelo
    Quintana, A. Garcia
    Amador, C.
    De Lezo, J. Suarez
    Ramirez, R.
    Ortega, J. R.
    Burgos, L. Ramirez
    Medina, A.
    EUROPEAN HEART JOURNAL, 2006, 27 : 894 - 894
  • [49] Impact of radiocontrast use during left ventricular pacemaker lead implantation for cardiac resynchronization therapy
    Tester, Gregory A.
    Noheria, Amit
    Carrico, Heather L.
    Mears, Jennifer A.
    Cha, Yong-Mei
    Powell, Brian D.
    Friedman, Paul A.
    Rea, Robert F.
    Hayes, David L.
    Asirvatham, Samuel J.
    EUROPACE, 2012, 14 (02): : 243 - 248
  • [50] Left ventricular endocardial pacing via the interventricular septum for cardiac resynchronization therapy: First report
    Gamble, James H. P.
    Bashir, Yaver
    Rajappan, Kim
    Betts, Tim R.
    HEART RHYTHM, 2013, 10 (12) : 1812 - 1814