Haemodynamic vector personalization of a quadripolar left ventricular lead used for cardiac resynchronization therapy: use of surface electrocardiogram and interventricular time delays

被引:7
|
作者
Trolese, Luca [1 ]
Biermann, Juergen [1 ]
Hartmann, Maximilian [1 ]
Schluermann, Fabienne [1 ]
Faber, Thomas S. [1 ]
Bode, Christoph [1 ]
Asbach, Stefan [1 ]
机构
[1] Univ Freiburg, Dept Cardiol & Angiol 1, Ctr Heart, D-79106 Freiburg, Germany
来源
EUROPACE | 2014年 / 16卷 / 10期
关键词
Cardiac resynchronization therapy; Quadripolar lead; Haemodynamics; QRS duration; Interventricular time delays; CHRONIC HEART-FAILURE; MULTICENTER; PARAMETERS; EXPERIENCE; DURATION;
D O I
10.1093/europace/euu136
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aims The choice of left ventricular pacing configurations (LVPCs) of quadripolar leads used for cardiac resynchronization therapy (CRT) affects haemodynamic response and thus may be a tool for device optimization. The value of surface electrocardiograms and interventricular time delays (IVDs) for optimization is unknown. Methods and results Sixteen patients implanted with a CRT device with a quadripolar LV lead underwent invasive testing of LV dP/dt. QRS durations at baseline (bl) and during biventricular pacing (biv) were measured using different LVPCs (total of 141 LVPCs; 8.8 per patient). Variations in QRS duration during biv were calculated for each patient (Delta QRS) and, when compared with intrinsic QRS duration, for all LVPCs (Delta QRS(LVPC)). Interventricular time delays between the poles of the LV lead were obtained from intracardiac electrograms. Delta IVD was calculated as IVDmax - IVDmin. Parameters were correlated with LV dP/dt. Delta QRS and Delta QRS(LVPC) both significantly correlated with LV dP/dt (P < 0.01). Correlation was found for patients with ischaemic (P < 0.001) and non-ischaemic cardiomyopathy (P < 0.05), and for patients with bl QRS duration >168 ms (P < 0.001), but not,168 ms (P = ns). The LVPC with shortest QRS duration also yielded maximal LV dP/dt in 6 of 16 patients (37.5%), and was equal or better in LV dP/dt in 12 of 16 patients (75%). Delta IVD neither correlated with Delta QRS nor Delta LV dP/dt. Conclusion Delta QRS predicts the maximal value of vector personalization in the individual. Reductions inQRS width, but not IVDs, correlate with acute haemodynamic response. Intraindividually, in 75% of patients, the LVPC with the shortest QRS duration gives equal or superior haemodynamic results when compared with the LVPC with longest QRS duration.
引用
收藏
页码:1476 / 1481
页数:6
相关论文
共 50 条
  • [21] Epicardial left ventricular lead for cardiac resynchronization therapy
    Fedorco, Marian
    Bulava, Alan
    Santavy, Petr
    Taborsky, Milos
    NEUROENDOCRINOLOGY LETTERS, 2014, 35 : 34 - 39
  • [22] Performance of a novel left ventricular lead with short bipolar spacing for cardiac resynchronization therapy: Primary results of the Attain Performa Quadripolar Left Ventricular Lead Study
    Crossley, George H.
    Biffi, Mauro
    Johnson, Ben
    Lin, Albert
    Gras, Daniel
    Hussin, Azlan
    Cuffio, Allen
    Collier, Jack L.
    El-Chami, Mikhael
    Li, Shelby
    Holloman, Keith
    Exner, Derek V.
    HEART RHYTHM, 2015, 12 (04) : 751 - 758
  • [23] Bipolar versus quadripolar left ventricular leads for cardiac resynchronization therapy: evidence to date
    Fyenbo, Daniel Benjamin
    Frausing, Maria Hee Jung Park
    Kronborg, Mads Brix
    EXPERT REVIEW OF CARDIOVASCULAR THERAPY, 2021, 19 (12) : 1075 - 1084
  • [24] Clinical outcome of cardiac resynchronization therapy in patients randomized to an active fixation bipolar left ventricular lead versus a passive quadripolar lead
    Keilegavlen, Havard
    Schuster, Peter
    Hovstad, Thomas
    Faerestrand, Svein
    SCANDINAVIAN CARDIOVASCULAR JOURNAL, 2021, 55 (03) : 153 - 159
  • [25] Vector Selection of a Quadripolar Left Ventricular Pacing Lead Affects Acute Hemodynamic Response to Cardiac Resynchronization Therapy: A Randomized Cross-Over Trial
    Asbach, Stefan
    Hartmann, Maximilian
    Wengenmayer, Tobias
    Graf, Erika
    Bode, Christoph
    Biermann, Juergen
    PLOS ONE, 2013, 8 (06):
  • [26] Safety of MitraClip Implantation in Patients With a Left Ventricular Endocardial Lead for Cardiac Resynchronization Therapy Through the Interventricular Septum
    Lopez-Minguez, Jose R.
    Estevez-Loureiro, Rodrigo
    Millan-Nunez, Victoria
    Eugenia Fuentes-Canamero, Maria
    Gonzalez-Fernandez, Reyes
    Garrote-Coloma, Carmen
    REVISTA ESPANOLA DE CARDIOLOGIA, 2018, 71 (10): : 867 - 869
  • [27] Impacted left ventricular lead technique in cardiac resynchronization therapy
    Chan, Ngai Yin
    Lo, Ying Keung
    EUROPACE, 2007, 9 (07): : 531 - 532
  • [28] Thoracoscopic Left Ventricular Lead Implantation in Cardiac Resynchronization Therapy
    Jeong, Dong Seop
    Park, Pyo Won
    Lee, Young Tak
    Park, Seung-Jung
    Kim, June Soo
    On, Young Keun
    JOURNAL OF KOREAN MEDICAL SCIENCE, 2012, 27 (12) : 1595 - 1597
  • [29] Importance of left ventricular lead position in cardiac resynchronization therapy
    Bleeker, Gabe B.
    Schalij, Martin J.
    Bax, Jeroen J.
    EUROPEAN HEART JOURNAL, 2007, 28 (10) : 1182 - 1183
  • [30] Cardiac resynchronization therapy: a comparison among left ventricular bipolar, quadripolar and active fixation leads
    M. Ziacchi
    I. Diemberger
    A. Corzani
    C. Martignani
    A. Mazzotti
    G. Massaro
    C. Valzania
    C. Rapezzi
    G. Boriani
    M. Biffi
    Scientific Reports, 8