Measurement of Sap Flow Dynamics through the Tomato Peduncle Using a Non-Invasive Sensor Based on the Heat Field Deformation Method

被引:14
|
作者
Hanssens, J. [1 ]
De Swaef, T.
Nadezhdina, N. [2 ]
Steppe, K. [1 ]
机构
[1] Univ Ghent, Fac Biosci Engn, Plant Ecol Lab, B-9000 Ghent, Belgium
[2] Mendel Univ Brno, Inst Forest Ecol, Brno, Czech Republic
来源
关键词
tomato; sap flow; heat field deformation; sensor; peduncle; xylem; phloem; WATER RELATIONS; REVERSE FLOW; FRUIT; GROWTH; DEFICIT; PHLOEM; ROOTS;
D O I
10.17660/ActaHortic.2013.991.50
中图分类号
Q94 [植物学];
学科分类号
071001 ;
摘要
Recent contradicting evidence on the contributions of xylem and phloem to tomato fruit growth highlights the need for a more thorough insight into the dynamics of sap flow through the tomato peduncle. In fact, knowledge on sap flow dynamics through small plant parts remains scarce, due to a lack of direct measurements. Most currently available sap flow sensors use needles, making them inappropriate for the direct measurement of sap flow through small plant parts such as a tomato peduncle. Therefore, a non-invasive sap flow sensor based on the heat field deformation (HFD) principle was tested on the peduncle of a tomato truss. This mini HFD sensor, consisting of a heater element and three thermocouples stitched on insulation tape, was wrapped around the peduncle and allowed continuous monitoring of changes in the heat field around the heater caused by sap flow. Actual influx into the tomato truss was calculated based on fruit growth data and estimates of fruit transpiration and was compared with the dynamics measured with the mini HFD sensor. Additionally, heat girdling of the peduncle was performed to block phloem influx to study the dynamics of xylem and phloem influx using the mini HFD sensor. First results of the mini HFD sensor were promising and the measured sap flow dynamics through the tomato peduncle agreed well with the calculated sap influx. Results of the girdling experiment suggested opposite patterns of xylem and phloem influx, with a decreased xylem influx during the daytime. Furthermore, the pattern of xylem influx revealed a close relation with the total water potential in the stem. As such, the mini HFD sensor provided direct measurements of sap flow dynamics through a tomato peduncle and, hence, has a large potential to finally resolve the controversy on water influx into developing fruits.
引用
收藏
页码:409 / 416
页数:8
相关论文
共 50 条
  • [41] A non-invasive oil temperature measurement technology based on heat transfer model
    Cai Wei
    Xu Wenhua
    Dai Minqiang
    Li Hui
    CURRENT DEVELOPMENT OF MECHANICAL ENGINEERING AND ENERGY, PTS 1 AND 2, 2014, 494-495 : 890 - 894
  • [42] Method for observing stem water storage dynamics based on a sap flow rate sensor
    Yun, Yuliang
    Sheng, Wenyi
    Sun, Yurui
    Nongye Jixie Xuebao/Transactions of the Chinese Society for Agricultural Machinery, 2014, 45 (05): : 247 - 252
  • [43] Non-Invasive Urodynamic Analysis Using the Computational Fluid Dynamics Method Based on MR Images
    Atesci, Yusuf Z.
    Senturk, Utku
    Pekedis, Mahmut
    Cinar, Murat
    TURKIYE KLINIKLERI TIP BILIMLERI DERGISI, 2011, 31 (05): : 1186 - 1193
  • [44] A NON-INVASIVE APPROACH TO QUANTITATIVE MEASUREMENT OF FLOW THROUGH CSF SHUNTS - TECHNICAL NOTE
    STEIN, SC
    APFEL, S
    JOURNAL OF NEUROSURGERY, 1981, 54 (04) : 556 - 558
  • [45] A Non-Invasive Tumor Hyperthermia Method Based on Microwave Field Shaping
    Ma, Meng-Lu
    Zhao, Deshuang
    Wang, Yiling
    Liang, Feng
    Deng, Jianhua
    Yan, Dejin
    Wang, Bing-Zhong
    2022 INTERNATIONAL CONFERENCE ON MICROWAVE AND MILLIMETER WAVE TECHNOLOGY (ICMMT), 2022,
  • [46] Non-invasive monitoring of tomato graft dynamics using thermography and fluorescence quantum yields measurements
    Frey, Carlos
    Hernandez-Barriuso, Andres
    Encina, Antonio
    Acebes, Jose Luis
    PHYSIOLOGIA PLANTARUM, 2023, 175 (03) : e13935
  • [47] A NON-INVASIVE METHOD FOR MEASUREMENT OF CEREBRAL BLOOD-FLOW IN SPONTANEOUS MENINGEAL HEMORRHAGE
    TREMOULET, M
    GERAUD, G
    GUELL, A
    BES, A
    NEUROCHIRURGIE, 1983, 29 (04) : 235 - 240
  • [48] Non-invasive Blood Pressure Measurement by Pulse Wave Analysis Using FBG Sensor
    Katsuragawa, Yui
    Ishizawa, Hiroaki
    2015 IEEE INTERNATIONAL INSTRUMENTATION AND MEASUREMENT TECHNOLOGY CONFERENCE (I2MTC), 2015, : 511 - 515
  • [49] LED Based Sensor System for Non-Invasive Measurement of the Hemoglobin Concentration in Human Blood
    Timm, U.
    Lewis, E.
    McGrath, D.
    Kraitl, J.
    Ewald, H.
    13TH INTERNATIONAL CONFERENCE ON BIOMEDICAL ENGINEERING, VOLS 1-3, 2009, 23 (1-3): : 825 - +
  • [50] NON-INVASIVE MEASUREMENT OF HUMAN FETAL CIRCULATION USING ULTRASOUND - NEW METHOD
    FITZGERALD, DE
    DRUMM, JE
    BRITISH MEDICAL JOURNAL, 1977, 2 (6100): : 1450 - 1451