Measurement of Sap Flow Dynamics through the Tomato Peduncle Using a Non-Invasive Sensor Based on the Heat Field Deformation Method

被引:14
|
作者
Hanssens, J. [1 ]
De Swaef, T.
Nadezhdina, N. [2 ]
Steppe, K. [1 ]
机构
[1] Univ Ghent, Fac Biosci Engn, Plant Ecol Lab, B-9000 Ghent, Belgium
[2] Mendel Univ Brno, Inst Forest Ecol, Brno, Czech Republic
来源
关键词
tomato; sap flow; heat field deformation; sensor; peduncle; xylem; phloem; WATER RELATIONS; REVERSE FLOW; FRUIT; GROWTH; DEFICIT; PHLOEM; ROOTS;
D O I
10.17660/ActaHortic.2013.991.50
中图分类号
Q94 [植物学];
学科分类号
071001 ;
摘要
Recent contradicting evidence on the contributions of xylem and phloem to tomato fruit growth highlights the need for a more thorough insight into the dynamics of sap flow through the tomato peduncle. In fact, knowledge on sap flow dynamics through small plant parts remains scarce, due to a lack of direct measurements. Most currently available sap flow sensors use needles, making them inappropriate for the direct measurement of sap flow through small plant parts such as a tomato peduncle. Therefore, a non-invasive sap flow sensor based on the heat field deformation (HFD) principle was tested on the peduncle of a tomato truss. This mini HFD sensor, consisting of a heater element and three thermocouples stitched on insulation tape, was wrapped around the peduncle and allowed continuous monitoring of changes in the heat field around the heater caused by sap flow. Actual influx into the tomato truss was calculated based on fruit growth data and estimates of fruit transpiration and was compared with the dynamics measured with the mini HFD sensor. Additionally, heat girdling of the peduncle was performed to block phloem influx to study the dynamics of xylem and phloem influx using the mini HFD sensor. First results of the mini HFD sensor were promising and the measured sap flow dynamics through the tomato peduncle agreed well with the calculated sap influx. Results of the girdling experiment suggested opposite patterns of xylem and phloem influx, with a decreased xylem influx during the daytime. Furthermore, the pattern of xylem influx revealed a close relation with the total water potential in the stem. As such, the mini HFD sensor provided direct measurements of sap flow dynamics through a tomato peduncle and, hence, has a large potential to finally resolve the controversy on water influx into developing fruits.
引用
收藏
页码:409 / 416
页数:8
相关论文
共 50 条
  • [31] Non-invasive methods for flow field measurement. Part 1. The measurement device
    Szafran, Roman Grzegorz
    Ludwig, Wojciech
    Patronik, Piotr
    PRZEMYSL CHEMICZNY, 2011, 90 (04): : 580 - 586
  • [32] Non-Invasive Blood Components Measurement Using Optical Sensor System Interface
    Raikham, Pamshangphy
    Kumar, Rohit
    Shah, Rahul Kumar
    Hazarika, Mery
    Sonkar, R. K.
    2018 3RD INTERNATIONAL CONFERENCE ON MICROWAVE AND PHOTONICS (ICMAP), 2018,
  • [33] Non-invasive Measurement of Complex permittivity using a Compact Planar Microwave Sensor
    Moolat, Remsha
    Mani, Manoj
    Pezholil, Mohanan
    2022 3RD URSI ATLANTIC AND ASIA PACIFIC RADIO SCIENCE MEETING (AT-AP-RASC), 2022,
  • [34] Non-Invasive Assessment of Coronary Microvascular Dysfunction Using Vascular Deformation-Based Flow Estimation
    Xue, Xiaofei
    Deng, Dan
    Zhang, Heye
    Gao, Zhifan
    Zhu, Ping
    Hau, William Kongto
    Zhang, Zhihui
    Liu, Xiujian
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2024, 71 (10) : 3000 - 3013
  • [35] Non-invasive glucometer monitoring system through optical based near-infrared sensor method
    Vanaja, S.
    Babu, Ravi T.
    Malathi, K.
    Saxena, Kuldeep K.
    Sheela, J. Joselin Jeya
    Suruthi, S.
    Stalin, B.
    Nagaprasad, N.
    Krishnaraj, Ramaswamy
    Bandhu, Din
    Reddy, Uma
    COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING-IMAGING AND VISUALIZATION, 2024, 12 (01):
  • [36] A new approach combining microwave heat pulse and infrared for non-invasive flow measurement
    Louche, Herve
    Penarier, Annick
    Nouvel, Philippe
    Clair, Bruno
    Coillot, Christophe
    Do, Frederic C.
    AGRICULTURAL AND FOREST METEOROLOGY, 2024, 347
  • [37] Non-invasive blood pressure measurement based on the electronic palpation method
    Nissilä, S
    Sorvisto, M
    Sorvoja, H
    Vieri-Gashi, E
    Myllylä, R
    PROCEEDINGS OF THE 20TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOL 20, PTS 1-6: BIOMEDICAL ENGINEERING TOWARDS THE YEAR 2000 AND BEYOND, 1998, 20 : 1723 - 1726
  • [38] Research on Non-Invasive Voltage Measurement Method Based on Impedance Adaptation
    Ao, Gang
    Tang, Jie
    Li, Dongdong
    Zhang, Wenbin
    Yang, Le
    Xu, Zhipeng
    INTEGRATED FERROELECTRICS, 2024, 240 (03) : 517 - 533
  • [39] Non-Invasive Determination of Glucose Concentration Using a Near-Field Sensor
    Gorst, Aleksandr
    Zavyalova, Kseniya
    Mironchev, Aleksandr
    BIOSENSORS-BASEL, 2021, 11 (03):
  • [40] A Simplified Equation for Sap Flow Calculation Based on the Heat-Field Deformation (HFD) Measurements
    Nadezhdina, N.
    VIII INTERNATIONAL SYMPOSIUM ON SAP FLOW, 2012, 951 : 117 - 120