A sensitive spectrophotometric method for lead determination by flow injection analysis with on-line preconcentration

被引:44
|
作者
Di Nezio, MS [1 ]
Palomeque, ME [1 ]
Band, BSF [1 ]
机构
[1] Univ Nacl Sur, Dept Chem, FIA Lab, RA-8000 Bahia Blanca, Buenos Aires, Argentina
关键词
lead; preconcentration; spectrophotometric; FIA;
D O I
10.1016/j.talanta.2003.11.012
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A new flow injection (FI) system for the determination of Pb(II) at trace level with a preconcentration step and spectrophotometric detection is proposed. It is based on preconcentration of lead ions on chitosan and dithizone-lead complex formation in aqueous medium (pH 9). The chemicals and FIA variables influencing the performance of the system were optimized and applied to the determination of lead in natural, well, and drinking water samples. It is a simple, highly sensitive, and low cost alternative methodology. The method provided a linear rage between 25 and 250 mug l(-1), a detection limit of 5.0 ng ml(-1) and a sample throughput of 15 h-(1). The obtained results of spiked samples ate in good agreement between the proposed method and ICP-AES. (C) 2003 Elsevier B.V. All rights reserved.
引用
收藏
页码:405 / 409
页数:5
相关论文
共 50 条
  • [31] On-line preconcentration with different solid adsorbents for lead determination
    J. B. B. da Silva
    S. P. Quináia
    M. C. E. Rollemberg
    Fresenius' Journal of Analytical Chemistry, 2001, 369 : 657 - 660
  • [32] Immobilized stearic acid as a new sorbent for on-line preconcentration and determination of lead by flow injection flame atomic absorption spectrometry
    Dadfarnia, Shayessteh
    Shabani, Ali Mohammed Haji
    Dehghani, Zahra
    JOURNAL OF THE BRAZILIAN CHEMICAL SOCIETY, 2006, 17 (03) : 548 - 554
  • [33] On-line preconcentration system for determination of lead in water and sediment samples by flow injection-flame atomic absorption spectrometry
    Soylak, M
    Elci, L
    Akkaya, Y
    Dogan, M
    ANALYTICAL LETTERS, 2002, 35 (03) : 487 - 499
  • [34] A Flow Injection On-Line Unequal Flow Complexation Preconcentration Procedure Coupled with Flame Atomic Absorption Spectrometry for Determination of Lead in Tap Water
    Wang Zhong-yuan
    Su Yao-dong
    Li Shuang
    Gan Li-hua
    SPECTROSCOPY AND SPECTRAL ANALYSIS, 2008, 28 (11) : 2695 - 2698
  • [35] ETAAS determination of lead with on-line preconcentration using a flow-through electrochemical microcell
    Bulska, E
    Jedral, W
    ATOMIC SPECTROSCOPY, 1997, 18 (06) : 202 - 205
  • [36] Determination of Iron( II ) and Total Iron Using Flow Injection On-line Preconcentration with FAAS
    Xu, Guang-Ming
    Ye, Ying-Xue
    Yin, Xue-Feng
    Shen, Hong
    Ali, Akbar
    Kao Teng Hsueh Hsiao Hua Heush Hsueh Pao/ Chemical Journal of Chinese Universities, 2000, 21 (03): : 352 - 353
  • [37] Flow injection atomic absorption spectrometric determination of iodide using an on-line preconcentration technique
    Yebra, MC
    Cespón, RM
    FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 2000, 367 (01): : 24 - 28
  • [38] Determination of iron(II) and total iron using flow injection on-line preconcentration with FAAS
    Xu, GM
    Ye, YX
    Yin, XF
    Shen, H
    Ali, A
    CHEMICAL JOURNAL OF CHINESE UNIVERSITIES-CHINESE, 2000, 21 (03): : 350 - 353
  • [39] Sequential injection spectrophotometric analysis of nitrite in natural waters using an on-line solid-phase extraction and preconcentration method
    Miró, M
    Cladera, A
    Estela, JM
    Cerdà, V
    ANALYST, 2000, 125 (05) : 943 - 948
  • [40] Determination of chromium (VI) by flow-injection spectrophotometry coupled with on-line microcolumn preconcentration
    Ma, WH
    Cai, RX
    Chen, DH
    LABORATORY ROBOTICS AND AUTOMATION, 1999, 11 (03) : 141 - 145