A sensitive spectrophotometric method for lead determination by flow injection analysis with on-line preconcentration

被引:44
|
作者
Di Nezio, MS [1 ]
Palomeque, ME [1 ]
Band, BSF [1 ]
机构
[1] Univ Nacl Sur, Dept Chem, FIA Lab, RA-8000 Bahia Blanca, Buenos Aires, Argentina
关键词
lead; preconcentration; spectrophotometric; FIA;
D O I
10.1016/j.talanta.2003.11.012
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A new flow injection (FI) system for the determination of Pb(II) at trace level with a preconcentration step and spectrophotometric detection is proposed. It is based on preconcentration of lead ions on chitosan and dithizone-lead complex formation in aqueous medium (pH 9). The chemicals and FIA variables influencing the performance of the system were optimized and applied to the determination of lead in natural, well, and drinking water samples. It is a simple, highly sensitive, and low cost alternative methodology. The method provided a linear rage between 25 and 250 mug l(-1), a detection limit of 5.0 ng ml(-1) and a sample throughput of 15 h-(1). The obtained results of spiked samples ate in good agreement between the proposed method and ICP-AES. (C) 2003 Elsevier B.V. All rights reserved.
引用
收藏
页码:405 / 409
页数:5
相关论文
共 50 条
  • [21] Sequential injection spectrophotometric determination of nanomolar nitrite in seawater by on-line preconcentration with HLB cartridge
    Min Zhang
    Dongxing Yuan
    Yongming Huang
    Guohe Chen
    Zhen Zhang
    Acta Oceanologica Sinica, 2010, 29 : 100 - 107
  • [22] Sequential injection spectrophotometric determination of nanomolar nitrite in seawater by on-line preconcentration with HLB cartridge
    Zhang Min
    Yuan Dongxing
    Huang Yongming
    Chen Guohe
    Zhang Zhen
    ACTA OCEANOLOGICA SINICA, 2010, 29 (01) : 100 - 107
  • [23] On-line preconcentration and determination of lead and cadmium by sequential injection/anodic stripping voltammetry
    Ninwong, Benjawan
    Chuanuwatanakul, Suchada
    Chailapakul, Orawon
    Dungchai, Wijitar
    Motomizu, Shoji
    TALANTA, 2012, 96 : 75 - 81
  • [24] DETERMINATION OF IRON IN SEAWATER BY FLOW INJECTION-ANALYSIS USING IN-LINE PRECONCENTRATION AND SPECTROPHOTOMETRIC DETECTION
    MEASURES, CI
    YUAN, J
    RESING, JA
    MARINE CHEMISTRY, 1995, 50 (1-4) : 3 - 12
  • [25] Flow injection on-line spectrophotometric determination of thorium(IV) after preconcentration on XAD-4 resin impregnated with oxytetracycline
    Shabnam Shahida
    Akbar Ali
    Muhammad Haleem Khan
    Journal of the Iranian Chemical Society, 2014, 11 : 1 - 8
  • [26] Flow injection on-line spectrophotometric determination of thorium(IV) after preconcentration on XAD-4 resin impregnated with oxytetracycline
    Shahida, Shabnam
    Ali, Akbar
    Khan, Muhammad Haleem
    JOURNAL OF THE IRANIAN CHEMICAL SOCIETY, 2014, 11 (01) : 1 - 8
  • [27] ON-LINE FLOW INJECTION SPECTROPHOTOMETRIC DETERMINATION OF CHLORIDE ION IN TANNERY EFFLUENT
    Yu Lingyun
    Zhang Xinshen
    Sun Dongmie
    Tong Ling
    Dai Shijun
    Xiao Kai
    Tu Jie
    JOURNAL OF THE SOCIETY OF LEATHER TECHNOLOGISTS AND CHEMISTS, 2009, 93 (02): : 46 - 50
  • [28] Flow injection preconcentration by chemofiltration and spectrophotometric determination of Gd
    De Vito, IE
    Olinsa, RA
    Raba, J
    Masi, AN
    ANALYTICA CHIMICA ACTA, 2004, 501 (01) : 11 - 16
  • [29] On-line preconcentration and determination of cobalt by chelating microcolumns and flow injection atomic spectrometry
    Shabani, AMH
    Dadfarnia, S
    Dehghan, K
    TALANTA, 2003, 59 (04) : 719 - 725
  • [30] On-line preconcentration with different solid adsorbents for lead determination
    da Silva, JBB
    Quináia, SP
    Rollemberg, MCE
    FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 2001, 369 (7-8): : 657 - 660