Applicability and reproducibility of 2D multi-slice GRASE myelin water fraction with varying acquisition acceleration

被引:29
|
作者
Drenthen, Gerhard S. [1 ,2 ,4 ]
Backes, Walter H. [1 ,2 ]
Aldenkamp, Albert P. [1 ,3 ,4 ]
Jansen, Jacobus F. A. [1 ,2 ,4 ]
机构
[1] Maastricht Univ, Med Ctr, Sch Mental Hlth & Neurosci, P Debyelaan 25, Maastricht, Netherlands
[2] Maastricht Univ, Med Ctr, Dept Radiol & Nucl Med, P Debyelaan 25, Maastricht, Netherlands
[3] Epilepsy Ctr Kempenhaeghe, Dept Behav Sci, Sterkselseweg 65, Heeze, Netherlands
[4] Eindhoven Univ Technol, Dept Elect Engn, De Rondom 70, Eindhoven, Netherlands
关键词
Myelin water fraction; T2; relaxometry; Reproducibility; MULTIPLE-SCLEROSIS; RELAXATION; BRAIN; RELIABILITY; MRI;
D O I
10.1016/j.neuroimage.2019.04.011
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
Non-invasive quantification of the in vivo myelin content may provide valuable information regarding healthy maturation of the brain, as well as insights into demyelination of several neurological disorders. However, these scans are often long thereby limiting acquisition of large brain parts in clinically feasible acquisition times. Therefore, fast acquisition of whole brain myelin content is important. To avoid errors related to slice-selective pulses, most of the previous whole brain studies on myelin content relied on a 3D acquisition. However, multi-slice (2D) acquisition methods are often faster, and less susceptible to motion artifacts. Therefore, multi-slice approaches can be beneficial in a clinical setting. We investigated the applicability and reproducibility of whole brain multi-slice GRASE myelin-water imaging with post-acquisition slice-profile correction in healthy volunteers (aged 25-32y). The applicability was evaluated using the agreement between the multi-slice GRASE and the reference method for myelin-water imaging, single-slice multi spin-echo (MSE) acquisition. Additionally, we assessed the effect of varying acquisition acceleration using parallel imaging on the reproducibility values. First, the multi-slice myelin-water maps showed good agreement with the single-slice reference method, with a bias of at most 1.2% in absolute MWF values. Second, we found an average within-subject coefficient of variation (CoV) of 5.9% and an average intra-class correlation coefficient (ICC) of 0.90 for myelin-water estimation using a multi-slice GRASE sequence without parallel acceleration (scan time 14:06 min), while acquisition with a parallel acceleration factor of 2 resulted in a slightly worse average within-subject CoV of 6.4% and an average ICC of 0.83 at half the scan time. Hence, a multi-slice GRASE acquisition with parallel acceleration factor 2 and a scan time of 7:30 min still provides an excellent reproducibility.
引用
收藏
页码:333 / 339
页数:7
相关论文
共 36 条
  • [31] 3D visualisation of the middle ear and adjacent structures using reconstructed multi-slice CT datasets, correlating 3D images and virtual endoscopy to the 2D cross-sectional images
    T. Rodt
    P. Ratiu
    H. Becker
    S. Bartling
    D. Kacher
    M. Anderson
    F. Jolesz
    R. Kikinis
    Neuroradiology, 2002, 44 : 783 - 790
  • [32] Free breathing 2D multi-slice real-time gradient-echo cardiovascular magnetic resonance imaging: impact on left ventricular function measurements compared with standard multi-breath hold 2D steady-state free precession imaging
    Sievers, Burkhard
    Schrader, Sebastian
    Hunold, Peter
    Barkhausen, Joerg
    Erbel, Raimund
    ACTA CARDIOLOGICA, 2011, 66 (04) : 489 - 497
  • [33] Real-time, single breath-hold, multi-slice, 2D cine radial MR image reconstruction using sc-GROG k-t ESPIRiT
    Aslam, Ibtisam
    Crowe, Lindsey A.
    Kassai, Miklos
    Qazi, Sohaib Ayaz
    Omer, Hammad
    Vallee, Jean-Paul
    BIOMEDICAL PHYSICS & ENGINEERING EXPRESS, 2022, 8 (06)
  • [34] Volumetric Cine MRI (VC-MRI) Using Motion Modeling, Free-Form Deformation and Multi-Slice Undersampled 2D Cine MRI Reconstructed with Spatio-Temporal Low-Rank Decomposition
    Harris, W.
    Yin, F.
    Ren, L.
    MEDICAL PHYSICS, 2018, 45 (06) : E645 - E646
  • [35] Volumetric cine magnetic resonance imaging (VC-MRI) using motion modeling, free-form deformation and multi-slice undersampled 2D cine MRI reconstructed with spatio-temporal low-rank decomposition
    Harris, Wendy
    Yin, Fang-Fang
    Cai, Jing
    Ren, Lei
    QUANTITATIVE IMAGING IN MEDICINE AND SURGERY, 2020, 10 (02) : 432 - 450
  • [36] High-resolution multi-breath-held 3D volumetric T1 mapping acquisition: analysis of T1 measurement reproducibility compared to 2D T1 mapping with a respiratory motion phantom
    Keigo Kawaji
    Sui-Cheng Wang
    Akiko Tanaka
    Hui Wang
    Roberto Lang
    Amit R Patel
    Journal of Cardiovascular Magnetic Resonance, 17 (Suppl 1)