Applicability and reproducibility of 2D multi-slice GRASE myelin water fraction with varying acquisition acceleration

被引:29
|
作者
Drenthen, Gerhard S. [1 ,2 ,4 ]
Backes, Walter H. [1 ,2 ]
Aldenkamp, Albert P. [1 ,3 ,4 ]
Jansen, Jacobus F. A. [1 ,2 ,4 ]
机构
[1] Maastricht Univ, Med Ctr, Sch Mental Hlth & Neurosci, P Debyelaan 25, Maastricht, Netherlands
[2] Maastricht Univ, Med Ctr, Dept Radiol & Nucl Med, P Debyelaan 25, Maastricht, Netherlands
[3] Epilepsy Ctr Kempenhaeghe, Dept Behav Sci, Sterkselseweg 65, Heeze, Netherlands
[4] Eindhoven Univ Technol, Dept Elect Engn, De Rondom 70, Eindhoven, Netherlands
关键词
Myelin water fraction; T2; relaxometry; Reproducibility; MULTIPLE-SCLEROSIS; RELAXATION; BRAIN; RELIABILITY; MRI;
D O I
10.1016/j.neuroimage.2019.04.011
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
Non-invasive quantification of the in vivo myelin content may provide valuable information regarding healthy maturation of the brain, as well as insights into demyelination of several neurological disorders. However, these scans are often long thereby limiting acquisition of large brain parts in clinically feasible acquisition times. Therefore, fast acquisition of whole brain myelin content is important. To avoid errors related to slice-selective pulses, most of the previous whole brain studies on myelin content relied on a 3D acquisition. However, multi-slice (2D) acquisition methods are often faster, and less susceptible to motion artifacts. Therefore, multi-slice approaches can be beneficial in a clinical setting. We investigated the applicability and reproducibility of whole brain multi-slice GRASE myelin-water imaging with post-acquisition slice-profile correction in healthy volunteers (aged 25-32y). The applicability was evaluated using the agreement between the multi-slice GRASE and the reference method for myelin-water imaging, single-slice multi spin-echo (MSE) acquisition. Additionally, we assessed the effect of varying acquisition acceleration using parallel imaging on the reproducibility values. First, the multi-slice myelin-water maps showed good agreement with the single-slice reference method, with a bias of at most 1.2% in absolute MWF values. Second, we found an average within-subject coefficient of variation (CoV) of 5.9% and an average intra-class correlation coefficient (ICC) of 0.90 for myelin-water estimation using a multi-slice GRASE sequence without parallel acceleration (scan time 14:06 min), while acquisition with a parallel acceleration factor of 2 resulted in a slightly worse average within-subject CoV of 6.4% and an average ICC of 0.83 at half the scan time. Hence, a multi-slice GRASE acquisition with parallel acceleration factor 2 and a scan time of 7:30 min still provides an excellent reproducibility.
引用
收藏
页码:333 / 339
页数:7
相关论文
共 36 条
  • [21] Conservative Management in Three Cases of Prenatally Recognized Splenic Cyst Using 2D, 3D, Multi-Slice and Doppler Ultrasonography
    Dankovcik, Robert
    Urdzik, Peter
    Lazar, Igor
    Gresova, Andrea
    Radonak, Jozef
    Jirasek, Jan E.
    Kucera, Eduard
    Feyereisl, Jaroslav
    Dudas, Marek
    FETAL DIAGNOSIS AND THERAPY, 2009, 26 (03) : 177 - 180
  • [22] Global and regional left ventricular function: a comparison between gated SPECT, 2D echocardiography and multi-slice computed tomography
    Maureen M. Henneman
    Jeroen J. Bax
    Joanne D. Schuijf
    J. Wouter Jukema
    Eduard R. Holman
    Marcel P. M. Stokkel
    Hildo J. Lamb
    Albert de Roos
    Ernst E. van der Wall
    European Journal of Nuclear Medicine and Molecular Imaging, 2006, 33 : 1452 - 1460
  • [23] 2D Multi-Slice and 3D k-Space Simulations using a 3D Quadric Head Phantom with MRI Properties
    Gach, H. Michael
    PROGRESS IN SYSTEMS ENGINEERING, 2015, 366 : 639 - 644
  • [24] Addressing efficiency and residual magnetization cross talk in multi-slice 2D steady-state free precession imaging of the heart
    Slavin, GS
    Rettmann, DW
    MAGNETIC RESONANCE IN MEDICINE, 2005, 53 (04) : 965 - 969
  • [25] MR susceptibility contrast imaging using a 2D simultaneous multi-slice gradient-echo sequence at 7T
    Bian, Wei
    Kerr, Adam B.
    Tranvinh, Eric
    Parivash, Sherveen
    Zahneisen, Benjamin
    Han, May H.
    Lock, Christopher B.
    Goubran, Maged
    Zhu, Kongrong
    Rutt, Brian K.
    Zeineh, Michael M.
    PLOS ONE, 2019, 14 (07):
  • [26] Therapy response evaluation of Malignant Lymphoma in Multi-slice CT: Should manual 2D measurements replaced by 3D measurements? Results of a multicenter study
    Buerke, B.
    Schuelke, C.
    Knauer, A.
    Fabel, M.
    dos Santos, Pinto D.
    Graser, A.
    Heindel, W.
    Wessling, J.
    ONKOLOGIE, 2012, 35 : 10 - 10
  • [27] Wall motion assessment using multi-slice CT: New application of post-processing interactive 2D/3D animated movie of the heart
    Mochizuki, T
    Koyama, Y
    Higashino, H
    Hosoi, S
    Ikezoe, J
    Pan, TS
    Shen, Y
    CIRCULATION, 2002, 106 (19) : 441 - 441
  • [28] Accelerated 2D multi-slice first-pass contrast-enhanced myocardial perfusion using through-time radial GRAPPA
    Jesse I Hamilton
    Kestutis Barkauskas
    Nicole Seiberlich
    Journal of Cardiovascular Magnetic Resonance, 16 (Suppl 1)
  • [29] Analytical corrections for B1-inhomogeneity and signal decay in multi-slice 2D spiral hyperpolarized 129Xe MRI using keyhole reconstruction
    Plummer, J. W.
    Hussain, R.
    Bdaiwi, A. S.
    Costa, M. L.
    Willmering, M. M.
    Parra-Robles, J.
    Cleveland, Z. I.
    Walkup, L. L.
    MAGNETIC RESONANCE IN MEDICINE, 2024, 92 (03) : 967 - 981
  • [30] 3D visualisation of the middle ear and adjacent structures using reconstructed multi-slice CT datasets, correlating 3D images and virtual endoscopy to the 2D cross-sectional images
    Rodt, T
    Ratiu, P
    Becker, H
    Bartling, S
    Kacher, DF
    Anderson, M
    Jolesz, FA
    Kikinis, R