Applicability and reproducibility of 2D multi-slice GRASE myelin water fraction with varying acquisition acceleration

被引:29
|
作者
Drenthen, Gerhard S. [1 ,2 ,4 ]
Backes, Walter H. [1 ,2 ]
Aldenkamp, Albert P. [1 ,3 ,4 ]
Jansen, Jacobus F. A. [1 ,2 ,4 ]
机构
[1] Maastricht Univ, Med Ctr, Sch Mental Hlth & Neurosci, P Debyelaan 25, Maastricht, Netherlands
[2] Maastricht Univ, Med Ctr, Dept Radiol & Nucl Med, P Debyelaan 25, Maastricht, Netherlands
[3] Epilepsy Ctr Kempenhaeghe, Dept Behav Sci, Sterkselseweg 65, Heeze, Netherlands
[4] Eindhoven Univ Technol, Dept Elect Engn, De Rondom 70, Eindhoven, Netherlands
关键词
Myelin water fraction; T2; relaxometry; Reproducibility; MULTIPLE-SCLEROSIS; RELAXATION; BRAIN; RELIABILITY; MRI;
D O I
10.1016/j.neuroimage.2019.04.011
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
Non-invasive quantification of the in vivo myelin content may provide valuable information regarding healthy maturation of the brain, as well as insights into demyelination of several neurological disorders. However, these scans are often long thereby limiting acquisition of large brain parts in clinically feasible acquisition times. Therefore, fast acquisition of whole brain myelin content is important. To avoid errors related to slice-selective pulses, most of the previous whole brain studies on myelin content relied on a 3D acquisition. However, multi-slice (2D) acquisition methods are often faster, and less susceptible to motion artifacts. Therefore, multi-slice approaches can be beneficial in a clinical setting. We investigated the applicability and reproducibility of whole brain multi-slice GRASE myelin-water imaging with post-acquisition slice-profile correction in healthy volunteers (aged 25-32y). The applicability was evaluated using the agreement between the multi-slice GRASE and the reference method for myelin-water imaging, single-slice multi spin-echo (MSE) acquisition. Additionally, we assessed the effect of varying acquisition acceleration using parallel imaging on the reproducibility values. First, the multi-slice myelin-water maps showed good agreement with the single-slice reference method, with a bias of at most 1.2% in absolute MWF values. Second, we found an average within-subject coefficient of variation (CoV) of 5.9% and an average intra-class correlation coefficient (ICC) of 0.90 for myelin-water estimation using a multi-slice GRASE sequence without parallel acceleration (scan time 14:06 min), while acquisition with a parallel acceleration factor of 2 resulted in a slightly worse average within-subject CoV of 6.4% and an average ICC of 0.83 at half the scan time. Hence, a multi-slice GRASE acquisition with parallel acceleration factor 2 and a scan time of 7:30 min still provides an excellent reproducibility.
引用
收藏
页码:333 / 339
页数:7
相关论文
共 36 条
  • [1] In vivo multi-slice mapping of myelin water content using T2* decay
    Hwang, Dosik
    Kim, Dong-Hyun
    Du, Yiping P.
    NEUROIMAGE, 2010, 52 (01) : 198 - 204
  • [2] Quantitative myocardial perfusion with a hybrid 2D simultaneous multi-slice sequence
    Huang, Qi
    Tian, Ye
    Mendes, Jason
    Ranjan, Ravi
    Adluru, Ganesh
    DiBella, Edward
    MAGNETIC RESONANCE IMAGING, 2023, 98 : 7 - 16
  • [3] Comparison of 2D simultaneous multi-slice and 3D GRASE readout schemes for pseudo-continuous arterial spin labeling of cerebral perfusion at 3 T
    Nanjappa, Manjunathan
    Troalen, Thomas
    Pfeuffer, Josef
    Marechal, Benedicte
    Hilbert, Tom
    Kober, Tobias
    Schneider, Fabien C.
    Croisille, Pierre
    Viallon, Magalie
    MAGNETIC RESONANCE MATERIALS IN PHYSICS BIOLOGY AND MEDICINE, 2021, 34 (03) : 437 - 450
  • [4] Comparison of 2D simultaneous multi-slice and 3D GRASE readout schemes for pseudo-continuous arterial spin labeling of cerebral perfusion at 3 T
    Manjunathan Nanjappa
    Thomas Troalen
    Josef Pfeuffer
    Bénédicte Maréchal
    Tom Hilbert
    Tobias Kober
    Fabien C. Schneider
    Pierre Croisille
    Magalie Viallon
    Magnetic Resonance Materials in Physics, Biology and Medicine, 2021, 34 : 437 - 450
  • [5] Compression of multi-slice CT: 2D vs. 3D JPEG 2000 and effects of slice thickness
    Siegel, E
    Siddiqui, K
    Johnson, J
    Crave, O
    Wu, ZY
    Dagher, J
    Bilgin, A
    Marcellin, M
    Nadar, M
    Reiner, B
    Medical Imaging 2005: PACS and Imaging Informatics, 2005, 5748 : 162 - 170
  • [6] An Efficient Interpolated Compressed Sensing Method for Highly Correlated 2D Multi-slice MRI
    Datta, Sumit
    Deka, Bhabesh
    Mullah, Helal Uddin
    Kumar, Sushant
    2016 INTERNATIONAL CONFERENCE ON ACCESSIBILITY TO DIGITAL WORLD (ICADW), 2016, : 187 - 192
  • [7] Fast Myelin Water Fraction Estimation Using 2D Multislice CPMG
    Akhondi-Asl, Alireza
    Afacan, Onur
    Balasubramanian, Mukund
    Mulkern, Robert V.
    Warfield, Simon K.
    MAGNETIC RESONANCE IN MEDICINE, 2016, 76 (04) : 1301 - 1313
  • [8] Functional Sensitivity of 2D Simultaneous Multi-Slice Echo-Planar Imaging: Effects of Acceleration on g-factor and Physiological Noise
    Todd, Nick
    Josephs, Oliver
    Zeidman, Peter
    Flandin, Guillaume
    Moeller, Steen
    Weiskopf, Nikolaus
    FRONTIERS IN NEUROSCIENCE, 2017, 11
  • [9] Automation of finite element aided design of induction motors using multi-slice 2D models
    Griffiths, DR
    Sykulski, JK
    COMPEL-THE INTERNATIONAL JOURNAL FOR COMPUTATION AND MATHEMATICS IN ELECTRICAL AND ELECTRONIC ENGINEERING, 2006, 25 (02) : 309 - 319
  • [10] Age-Related Measurements of the Myelin Water Fraction derived from 3D multi-echo GRASE reflect Myelin Content of the Cerebral White Matter
    Tobias D. Faizy
    Dushyant Kumar
    Gabriel Broocks
    Christian Thaler
    Fabian Flottmann
    Hannes Leischner
    Daniel Kutzner
    Simon Hewera
    Dominik Dotzauer
    Jan-Patrick Stellmann
    Ravinder Reddy
    Jens Fiehler
    Jan Sedlacik
    Susanne Gellißen
    Scientific Reports, 8