Short-wavelength automated perimetry in patients with migraine

被引:21
|
作者
Yenice, Ozlem [1 ]
Temel, Ahmet
Incili, Burcin
Tuncer, Nese
机构
[1] Marmara Univ, Sch Med, Dept Ophthalmol, Istanbul, Turkey
[2] Marmara Univ, Sch Med, Dept Neurol, Istanbul, Turkey
关键词
SWAP; migraine; glaucoma;
D O I
10.1007/s00417-005-0083-7
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
The aim was to investigate short-wavelength sensitivity deficits in patients with migraine. Fifteen migraine and 18 age-matched healthy volunteers with normal ophthalmologic examination participated in this study. Migraine characteristics were graded by the Migraine Disability Assessment Questionnaire (MIDAS). All participants underwent SWAP (short wavelength amplitude perimetry) testing using a Humphrey field analyzer; there was a 30-2 presentation pattern. Short wavelength amplitude perimetry parameters for mean deviation (MD; p < 0.0001) and pattern standard deviation (PSD; p < 0.0001) were significantly worse in the migraine group. In the migraine group 53.3%. of eyes had glaucoma hemi-field tests (GHT) outside normal limits and 10 of these had early glaucomatous visual field loss. Statistically significant correlations were found between frequency of migraine attacks and MD (p=0.02; r=0.56) and PSD (p=0.03; r=0.41) and also between the MIDAS score and MD (p=0.03; r=0.49) and PSD (p=0.04; r=0.51). In all migraine cases with early glaucomatous visual field defect a corresponding site of the head was predominantly involved in headache (p=0.03). Some patients with severe migraine have earlier defects on SWAP suggesting a common vascular insult of glaucoma and migraine, and all migraine cases with high MIDAS scores should be further evaluated for early glaucomatous visual field defects using SWAP.
引用
收藏
页码:589 / 595
页数:7
相关论文
共 50 条
  • [31] Comparison of Standard Automated Perimetry, Frequency-Doubling Technology Perimetry, and Short-Wavelength Automated Perimetry for Detection of Glaucoma
    Liu, Shu
    Lam, Shi
    Weinreb, Robert N.
    Ye, Cong
    Cheung, Carol Y.
    Lai, Gilda
    Lam, Dennis Shun-Chiu
    Leung, Christopher Kai-Shun
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2011, 52 (10) : 7325 - 7331
  • [32] Short-wavelength automated perimetry and standard perimetry in the detection of progressive optic disc cupping
    Girkin, CA
    Emdadi, A
    Sample, PA
    Blumenthal, EZ
    Lee, AC
    Zangwill, LM
    Weinreb, RN
    ARCHIVES OF OPHTHALMOLOGY, 2000, 118 (09) : 1231 - 1236
  • [33] Short-Wavelength Automated Perimetry Parameters at Baseline and Following Remission in Patients With Birdshot Retinochoroidopathy
    Maleki, Arash
    Swan, Robert T.
    Silpa-Archa, Sukhum
    Preble, Janine M.
    He, Yuchen
    Foster, C. Stephen
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2016, 163 : 83 - 92
  • [34] Comparison of conventional automated perimetry, short-wavelength automated perimetry and frequency-doubling technology in the assessment of patients with multiple sclerosis
    Corallo, G
    Capris, P
    Barabino, S
    Cicinelli, S
    Mastromarino, A
    Bandini, F
    Uccelli, A
    Solaro, C
    Zanardi, S
    Calabria, G
    PERIMETRY UPDATE 2002/2003, 2004, : 97 - 101
  • [35] Short-wavelength automated perimetry and capillary density in early diabetic maculopathy
    Remky, A
    Arend, O
    Hendricks, S
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2000, 41 (01) : 274 - 281
  • [36] Short-wavelength automated perimetry and nerve fiber analysis in glaucoma suspects
    Lee, VW
    Mok, KH
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1999, 40 (04) : S982 - S982
  • [37] Yellow-Tinted Intraocular Lenses on Short-Wavelength Automated Perimetry
    Ho, Jonathan Chun-Ho
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2011, 151 (02) : 380 - 380
  • [38] Long-term fluctuation in short-wavelength automated perimetry.
    Wild, JM
    Hosking, SL
    Hutchings, N
    Flanagan, JG
    ODonoghue, EP
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1997, 38 (04) : 2660 - 2660
  • [39] Statistical aspects of the normal visual field in short-wavelength automated perimetry
    Wild, JM
    Cubbidge, RP
    Pacey, IE
    Robinson, R
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1998, 39 (01) : 54 - 63
  • [40] Comparison of Standard Automated Perimetry, Short-Wavelength Automated Perimetry, and Frequency-Doubling Technology Perimetry to Monitor Glaucoma Progression
    Hu, Rongrong
    Wang, Chenkun
    Gu, Yangshun
    Racette, Lyne
    MEDICINE, 2016, 95 (07) : e2618