Performance evaluation of three automated human immunodeficiency virus antigen-antibody combination immunoassays

被引:53
|
作者
Kwon, Jung-Ah
Yoon, Soo-Young
Lee, Chang-Kyu
Lim, Chae Seung
Lee, Kap No
Sung, Hyun Ju
Brennan, Catherine A.
Devare, Sushil G.
机构
[1] Korea Univ, Coll Med, Dept Lab Med, Seoul 136701, South Korea
[2] Abbott Labs, Div Diagnost, Abbott, South Korea
[3] Abbott Labs, Div Diagnost, AIDS Res & Retrovirus Discovery, Abbott Pk, IL USA
关键词
fourth generation immunoassay; human immunodeficiency virus (HIV); p24; antigen; seroconversion;
D O I
10.1016/j.jviromet.2005.10.013
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Three fourth-generation antigen/antibody combination assays (Elecsys, AxSYM, Architect HIV) and two third-generation (AxSYM, Centaur) HIV antibody immunoassays were evaluated. The evaluation panel of 479 samples included: nine tissue culture derived HIV-1 strains at four different p24 antigen concentrations (n = 36), a p24 antigen sensitivity panel (n = 10), 149 HIV-1 or HIV-2 confirmed antibody positive samples, ten anti-HIV-1 positive low titer samples, three seroconversion panels (n = 2 1), and 253 HIV negative samples. The Architect had the best sensitivity for detection of HIV-1 antigen across eight HIV-1 subtypes, followed by the AxSYM while the Elecsys could not detect the highest antigen concentration evaluated (25 pg/mL) for eight of nine virus isolates. All assays showed 100% sensitivity for detection of HIV-1, group M, group 0, and HIV-2 antibody positive samples. The Architect Ag/Ab Combo assay detected the first positive bleed of the three seroconversion panels and detected infection 4-26 days earlier than the third generation assays. Based on evaluation of 253 negative samples, assay specificity varied from 98.0% to 99.6%. The Architect HIV Ag/Ab Combo exhibited the best performance for specificity and detection of p24 antigen leading to closure of seroconversion window and demonstrating its utility for early diagnosis of HIV infection. (c) 2005 Elsevier B.V. All rights reserved.
引用
收藏
页码:20 / 26
页数:7
相关论文
共 50 条
  • [41] ANTIGEN-ANTIBODY PRECIPITATES IN SOLID MEDIUM WITH INFLUENZA VIRUS
    JENSEN, KE
    FRANCIS, T
    JOURNAL OF IMMUNOLOGY, 1953, 70 (03): : 321 - 325
  • [42] Performance of an antigen-antibody combined assay for hepatitis C virus testing without venipuncture
    Larrat, Sylvie
    Bourdon, Cecile
    Baccard, Monique
    Garnaud, Cecile
    Mathieu, Sophie
    Quesada, Jean-Louis
    Signori-Schmuck, Anne
    Germi, Raphaele
    Blanc, Myriam
    Leclercq, Pascale
    Hilleret, Marie-Noelle
    Leroy, Vincent
    Zarski, Jean-Pierre
    Morand, Patrice
    JOURNAL OF CLINICAL VIROLOGY, 2012, 55 (03) : 220 - 225
  • [43] MECHANISM OF VIRUS- AND ANTIGEN-ANTIBODY COMPLEX INDUCED AGGREGATION OF HUMAN BLOOD PLATELETS
    MYLLYLA, G
    PENTTINE.K
    SCANDINAVIAN JOURNAL OF CLINICAL & LABORATORY INVESTIGATION, 1969, S 23 : 48 - &
  • [44] VIRUS-LIKE ANTIGEN ANTIBODY AND ANTIGEN-ANTIBODY COMPLEXES IN HEPATITIS MEASURED BY COMPLEMENT FIXATION
    SHULMAN, NR
    BARKER, LF
    SCIENCE, 1969, 165 (3890) : 304 - &
  • [45] STIMULATION OF NONIMMUNIZED HUMAN LYMPHOCYTES BY ANTIGEN-ANTIBODY COMPLEXES
    HIRSCHHORN, K
    BLOCHSHT.N
    UHR, JW
    JOURNAL OF CLINICAL INVESTIGATION, 1967, 46 (06): : 1070 - +
  • [46] A NEW PRECIPITATING ANTIGEN-ANTIBODY SYSTEM (PENNSYLVANIA ANTIGEN) IN HUMAN SERUM
    VIERUCCI, A
    BLUMBERG, BS
    LONDON, WT
    SUTNICK, AI
    LANCET, 1968, 1 (7554): : 1213 - +
  • [47] COMPLEXITY OF EB-VIRUS DETERMINED ANTIGEN-ANTIBODY SYSTEMS
    SVEDMYR, A
    DEMISSIE, A
    KLEIN, G
    CLIFFORD, P
    ACTA PATHOLOGICA ET MICROBIOLOGICA SCANDINAVICA SECTION A-PATHOLOGY, 1970, : 45 - &
  • [48] HEPATITIS-B VIRUS AND ANTIGEN-ANTIBODY COMPLEX DISEASES
    LONDON, WT
    NEW ENGLAND JOURNAL OF MEDICINE, 1977, 296 (26): : 1528 - 1529
  • [49] ANTIGEN-ANTIBODY MEDIATED DESENSITIZATION OF HUMAN LUNG FRAGMENTS
    DRAZEN, JM
    STECHSCHULTE, DJ
    AUSTEN, KF
    JOURNAL OF ALLERGY AND CLINICAL IMMUNOLOGY, 1973, 51 (02) : 80 - 80
  • [50] RADIOIMMUNOASSAY FOR HUMAN ANTIGEN-ANTIBODY COMPLEXES IN CLINICAL MATERIAL
    COWDERY, JS
    TREADWELL, PE
    FRITZ, RB
    JOURNAL OF IMMUNOLOGY, 1975, 114 (01): : 5 - 9