Performance of an antigen-antibody combined assay for hepatitis C virus testing without venipuncture

被引:25
|
作者
Larrat, Sylvie [1 ,2 ]
Bourdon, Cecile
Baccard, Monique [2 ]
Garnaud, Cecile
Mathieu, Sophie
Quesada, Jean-Louis [5 ]
Signori-Schmuck, Anne [2 ]
Germi, Raphaele [2 ]
Blanc, Myriam [6 ]
Leclercq, Pascale [6 ]
Hilleret, Marie-Noelle [3 ,4 ]
Leroy, Vincent [3 ,4 ]
Zarski, Jean-Pierre [3 ,4 ]
Morand, Patrice [2 ]
机构
[1] CHU Grenoble, Virol Lab, Inst Biol & Pathol, Dept Agents Infect, F-38043 Grenoble 9, France
[2] UMI 3265 UJF EMBL CNRS, Unit Virus Host Cell Interact, F-38042 Grenoble 9, France
[3] CHU Grenoble, Clin Univ Hepatogastroenterol, F-38043 Grenoble 9, France
[4] UJF U823 IAPC Inst Albert Bonniot, Unite INSERM, F-38706 La Tronche, France
[5] CHU Grenoble, INSERM 003, Ctr Invest Clin, F-38043 Grenoble 9, France
[6] CHU Grenoble, Clin Univ Infectiol, F-38043 Grenoble 9, France
关键词
Antigen-antibody combined detection; Alternative sampling; Dried blood spots; Oral mucosal transudate; High-risk population; HIV/HCV co-infection; DRIED BLOOD SPOTS; INJECTING DRUG-USERS; HCV CORE ANTIGEN; OF-CARE; CONTROLLED-TRIAL; ORAL FLUID; HIV; REPLICATION; PREVALENCE; INFECTION;
D O I
10.1016/j.jcv.2012.07.016
中图分类号
Q93 [微生物学];
学科分类号
071005 ; 100705 ;
摘要
Background: Hepatitis C virus (HCV) is underdiagnosed and therefore increasing the opportunities for HCV testing without venipuncture may be useful. Objectives: We evaluated the analytical performance of a modified, commercially available, combined HCV antigen-antibody assay (cEIA) (Monolisa (R) HCV-Ag-Ab-ULTRA) and a commercially available point-of-care (POC) device (OraQuick (R) HCV) on fingerstick blood (FSB) and oral mucosal transudate (OMT). Study design: FSB, OMT and serum samples were collected from 113 cases of HCV-antibody-positive patients and 88 HCV-antibody-negative controls. The HCV-antibody-positive group included 63 patients with quantifiable HCV-RNA (56%) and 17 HIV/HCV co-infected patients (15%). FSB and OMT specimens were collected as dried blood spots (DBSs) or with the OraSure collection system, before testing with cEIA. Results: With FSB specimens, the cEIA and the POC device exhibited 100% specificity and 98.2% and 97.4% sensitivity, respectively. The specificity of the cEIA in FSB sharply decreased if stored 3 days at room temperature. With OMT specimens, the cEIA sensitivity (71.7%) and specificity (94.3%) were significantly lower than the performance of OraQuick (R) HCV (sensitivity, 94.6%; specificity, 100%). The optical densities obtained with the cEIA in FSB and OMT were lower in HIV/HCV co-infected patients compared with HCV monoinfected patients. Conclusion: The cEIA using FSB specimens collected on DBSs preserved in appropriate storage conditions was a reliable alternative, equivalent to the POC assay, for HCV testing without venipuncture. The cEIA was not adapted for HCV testing on OMT. (C) 2012 Elsevier B.V. All rights reserved.
引用
收藏
页码:220 / 225
页数:6
相关论文
共 50 条
  • [1] Value of HCV antigen-antibody combined HCV assay in hepatitis c diagnosis
    Lambert, N.
    Advances in Transfusion Safety, Vol IV, 2007, 127 : 113 - 121
  • [2] HCV SCREENING WITHOUT VENIPUNCTURE: POINT-OF-CARE VERSUS LABORATORY-BASED ANTIGEN-ANTIBODY COMBINED ASSAY
    Larrat, Sylvie
    Bourdon, Cecile
    Baccard, Monique
    Garnaud, Cecile
    Hilleret, Marie Noelle
    Quesada, Jean-Louis
    Signori-Schmuck, Anne
    Leclercq, Pascale
    Leroy, Vincent
    Zarski, Jean-Pierre H.
    Morand, Patrice
    HEPATOLOGY, 2011, 54 : 573A - 574A
  • [3] Combined antigen/antibody testing in the serological diagnosis of hepatitis C virus in Ireland
    Purcell, M.
    Connell, J.
    IMMUNOLOGY, 2007, 120 : 74 - 75
  • [4] EVALUATION OF AN ANTIGEN-ANTIBODY "COMBINATION" ENZYME LINKED IMMUNOSORBENT ASSAY FOR DIAGNOSIS OF HEPATITIS C VIRUS INFECTIONS
    Odari, E. O.
    Budambula, N. L. M.
    Nitschko, H.
    ETHIOPIAN JOURNAL OF HEALTH SCIENCES, 2014, 24 (04) : 343 - 352
  • [5] Combined hepatitis C virus (HCV) antigen-antibody detection assay does not improve diagnosis for seronegative individuals with occult HCV infection
    Quiroga, Juan A.
    Castillo, Inmaculada
    Pardo, Margarita
    Rodriguez-Inigo, Elena
    Carreno, Vicente
    JOURNAL OF CLINICAL MICROBIOLOGY, 2006, 44 (12) : 4559 - 4560
  • [6] Analysis of hepatitis C virus infection among sickle cell anemia patients by an antigen-antibody combination assay
    Obeid, Obeid E.
    Alzahrani, Alhusain J.
    MICROBIOLOGY RESEARCH, 2011, 2 (02)
  • [7] PREFORMED ANTIGEN-ANTIBODY COMPLEX TO DETECT ANTIBODIES TO HEPATITIS-C VIRUS
    SHAH, D
    SALBILLA, V
    LUKAS, S
    KUPER, K
    HALL, H
    MAKELA, R
    SIX, LA
    HU, R
    RICHERSON, R
    CLINICAL CHEMISTRY, 1995, 41 (09) : 1357 - 1357
  • [8] Early detection of hepatitis C virus infection by use of a new combined antigen-antibody detection assay: Potential use for high-risk individuals
    Schnuriger, A
    Dominguez, S
    Valantin, MA
    Tubiana, R
    Duvivier, C
    Ghosn, J
    Simon, A
    Katlama, C
    Thibault, V
    JOURNAL OF CLINICAL MICROBIOLOGY, 2006, 44 (04) : 1561 - 1563
  • [9] Evaluation of a new combined hepatitis C antigen/antibody assay for routine HCV testing of patient samples
    Vermeersch, P.
    Van Meensel, B.
    Van Ranst, M.
    Lagrou, K.
    INTERNATIONAL JOURNAL OF ANTIMICROBIAL AGENTS, 2007, 29 : S539 - S539
  • [10] HEPATITIS-B VIRUS AND ANTIGEN-ANTIBODY COMPLEX DISEASES
    LONDON, WT
    NEW ENGLAND JOURNAL OF MEDICINE, 1977, 296 (26): : 1528 - 1529