Performance of an antigen-antibody combined assay for hepatitis C virus testing without venipuncture

被引:25
|
作者
Larrat, Sylvie [1 ,2 ]
Bourdon, Cecile
Baccard, Monique [2 ]
Garnaud, Cecile
Mathieu, Sophie
Quesada, Jean-Louis [5 ]
Signori-Schmuck, Anne [2 ]
Germi, Raphaele [2 ]
Blanc, Myriam [6 ]
Leclercq, Pascale [6 ]
Hilleret, Marie-Noelle [3 ,4 ]
Leroy, Vincent [3 ,4 ]
Zarski, Jean-Pierre [3 ,4 ]
Morand, Patrice [2 ]
机构
[1] CHU Grenoble, Virol Lab, Inst Biol & Pathol, Dept Agents Infect, F-38043 Grenoble 9, France
[2] UMI 3265 UJF EMBL CNRS, Unit Virus Host Cell Interact, F-38042 Grenoble 9, France
[3] CHU Grenoble, Clin Univ Hepatogastroenterol, F-38043 Grenoble 9, France
[4] UJF U823 IAPC Inst Albert Bonniot, Unite INSERM, F-38706 La Tronche, France
[5] CHU Grenoble, INSERM 003, Ctr Invest Clin, F-38043 Grenoble 9, France
[6] CHU Grenoble, Clin Univ Infectiol, F-38043 Grenoble 9, France
关键词
Antigen-antibody combined detection; Alternative sampling; Dried blood spots; Oral mucosal transudate; High-risk population; HIV/HCV co-infection; DRIED BLOOD SPOTS; INJECTING DRUG-USERS; HCV CORE ANTIGEN; OF-CARE; CONTROLLED-TRIAL; ORAL FLUID; HIV; REPLICATION; PREVALENCE; INFECTION;
D O I
10.1016/j.jcv.2012.07.016
中图分类号
Q93 [微生物学];
学科分类号
071005 ; 100705 ;
摘要
Background: Hepatitis C virus (HCV) is underdiagnosed and therefore increasing the opportunities for HCV testing without venipuncture may be useful. Objectives: We evaluated the analytical performance of a modified, commercially available, combined HCV antigen-antibody assay (cEIA) (Monolisa (R) HCV-Ag-Ab-ULTRA) and a commercially available point-of-care (POC) device (OraQuick (R) HCV) on fingerstick blood (FSB) and oral mucosal transudate (OMT). Study design: FSB, OMT and serum samples were collected from 113 cases of HCV-antibody-positive patients and 88 HCV-antibody-negative controls. The HCV-antibody-positive group included 63 patients with quantifiable HCV-RNA (56%) and 17 HIV/HCV co-infected patients (15%). FSB and OMT specimens were collected as dried blood spots (DBSs) or with the OraSure collection system, before testing with cEIA. Results: With FSB specimens, the cEIA and the POC device exhibited 100% specificity and 98.2% and 97.4% sensitivity, respectively. The specificity of the cEIA in FSB sharply decreased if stored 3 days at room temperature. With OMT specimens, the cEIA sensitivity (71.7%) and specificity (94.3%) were significantly lower than the performance of OraQuick (R) HCV (sensitivity, 94.6%; specificity, 100%). The optical densities obtained with the cEIA in FSB and OMT were lower in HIV/HCV co-infected patients compared with HCV monoinfected patients. Conclusion: The cEIA using FSB specimens collected on DBSs preserved in appropriate storage conditions was a reliable alternative, equivalent to the POC assay, for HCV testing without venipuncture. The cEIA was not adapted for HCV testing on OMT. (C) 2012 Elsevier B.V. All rights reserved.
引用
收藏
页码:220 / 225
页数:6
相关论文
共 50 条
  • [41] LIVER CYTOSOLIC-1 ANTIGEN-ANTIBODY SYSTEM IN TYPE-2 AUTOIMMUNE HEPATITIS AND HEPATITIS-C VIRUS-INFECTION
    LENZI, M
    MANOTTI, P
    MURATORI, L
    CATALETA, M
    BALLARDINI, G
    CASSANI, F
    BIANCHI, FB
    GUT, 1995, 36 (05) : 749 - 754
  • [42] Fast selection of antibodies without antigen purification:: Adaptation of the protein fragment complementation assay to select antigen-antibody pairs
    Mössner, E
    Koch, H
    Plückthun, A
    JOURNAL OF MOLECULAR BIOLOGY, 2001, 308 (02) : 115 - 122
  • [43] Hepatitis C virus antigen detection as a tool for diagnosis of acute hepatitis C in patients with negative hepatitis C virus antibody
    Kumar, Rajneesh
    Chan, Kwai Peng
    Ekstrom, Victoria
    Gan, Sheryl
    Thangaraju, Sobhana
    Kee, Terence
    Woo, Shi Min
    Foo, Marjorie
    Chan, Kian Sing
    Lim, Kun Lee
    Ean, Lynette Oon Lin
    Chow, Wan Cheng
    JOURNAL OF HEPATOLOGY, 2020, 73 : S324 - S325
  • [44] HEPATITIS-B VIRUS SURFACE ANTIGEN-ANTIBODY IMMUNE-COMPLEXES IN MALIGNANT NEPHROSCLEROSIS
    NAGY, J
    BAJTAI, G
    AMBRUS, M
    BRASCH, H
    SAMIK, J
    KARATSON, A
    DEAK, G
    BURGER, T
    ACTA MEDICA ACADEMIAE SCIENTIARUM HUNGARICAE, 1981, 38 (03) : 213 - 223
  • [45] Diagnostic performance of hepatitis E virus antigen assay in hepatitis E virus acute infection
    Lapa, Daniele
    Brega, Carla
    Mammone, Alessia
    Zaccarelli, Mauro
    Capobianchi, Maria Rosaria
    Garbuglia, Anna Rosa
    NEW MICROBIOLOGICA, 2017, 40 (04): : 246 - 250
  • [46] ANTIGEN-ANTIBODY PRECIPITATES IN SOLID MEDIUM WITH INFLUENZA VIRUS
    JENSEN, KE
    FRANCIS, T
    JOURNAL OF IMMUNOLOGY, 1953, 70 (03): : 321 - 325
  • [47] Evidence of hepatitis C virus viremia without detectable antibody to hepatitis C virus in a blood donor
    Durand, F
    Beauplet, A
    Marcellin, P
    ANNALS OF INTERNAL MEDICINE, 2000, 133 (01) : 74 - 75
  • [48] SCINTILLATION PROXIMITY ASSAY (SPA) OF ANTIGEN-ANTIBODY BINDING KINETICS
    HART, HE
    GREENWALD, EB
    JOURNAL OF NUCLEAR MEDICINE, 1978, 19 (06) : 681 - 681
  • [49] Improved Reflexive Testing Algorithm for Hepatitis C Infection Using Signal-to-Cutoff Ratios of a Hepatitis C Virus Antibody Assay
    Lai, Keane K. Y.
    Jin, Ming
    Yuan, Shan
    Larson, Meaghan F.
    Dominitz, Jason A.
    Bankson, Daniel D.
    CLINICAL CHEMISTRY, 2011, 57 (07) : 1050 - 1056
  • [50] Performance evaluation of three automated human immunodeficiency virus antigen-antibody combination immunoassays
    Kwon, Jung-Ah
    Yoon, Soo-Young
    Lee, Chang-Kyu
    Lim, Chae Seung
    Lee, Kap No
    Sung, Hyun Ju
    Brennan, Catherine A.
    Devare, Sushil G.
    JOURNAL OF VIROLOGICAL METHODS, 2006, 133 (01) : 20 - 26