Dosimetric feasibility of cone-beam CT-based treatment planning compared to CT-based treatment planning

被引:198
|
作者
Yoo, Sua [1 ]
Yin, Fang-Fang [1 ]
机构
[1] Duke Univ, Ctr Med, Dept Radiat Oncol, Durham, NC 27710 USA
关键词
cone-beam CT; HU values; treatment planning;
D O I
10.1016/j.ijrobp.2006.08.031
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: Cone-beam computed tomography (CBCT) images are currently used for positioning verification. However, it is yet unknown whether CBCT could be used in dose calculation for replanning in adaptive radiation therapy. This study investigates the dosimetric feasibility of CBCT-based treatment planning. Methods and Materials: Hounsfield unit (HU) values and profiles of Catphan, homogeneous/inhomogeneous phantoms, and various tissue regions of patients in CBCT images were compared to those in CT. The dosimetric consequence of the HU variation was investigated by comparing CBCT-based treatment plans to conventional CT-based plans for both phantoms and patients. Results: The maximum HU difference between CBCT and CT of Catphan was 34 HU in the Teflon. The differences in other materials were less than 10 HU. The profiles for the homogeneous phantoms in CBCT displayed reduced HU values up to 150 HU in the peripheral regions compared to those in CT. The scatter and artifacts in CBCT became severe surrounding inhomogeneous tissues with reduced HU values up to 200 HU. The MU/cGy differences were less than 1% for most phantom cases. The isodose distributions between CBCT-based and CT-based plans agreed very well. However, the discrepancy was larger when CBCT was scanned without a bowtie filter than with bowtie filter. Also, up to 3% dosimetric error was observed in the plans for the inhomogeneous phantom. In the patient studies, the discrepancies of isodose lines between CT-based and CBCT-based plans, both 3D and IMRT, were less than 2 mm. Again, larger discrepancy occurred for the lung cancer patients. Conclusion: This study demonstrated the feasibility of CBCT-based treatment planning. CBCT-based treatment plans were dosimetrically comparable to CT-based treatment plans. Dosimetric data in the inhomogeneous tissue regions should be carefully validated. (c) 2006 Elsevier Inc.
引用
收藏
页码:1553 / 1561
页数:9
相关论文
共 50 条
  • [21] A Feasibility Study of CT-Based IMRT Planning for Total Body Irradiation
    Hossain, M.
    Chen, Y.
    Fan, J.
    Lin, T.
    Price, R.
    Li, J.
    Ma, C.
    [J]. MEDICAL PHYSICS, 2008, 35 (06)
  • [22] PET-BASED RADIOTHERAPY TREATMENT PLANNING IS HIGHLY COST-EFFECTIVE COMPARED TO CT-BASED PLANNING: A MODEL-BASED EVALUATION
    Bongers, M. L.
    Coupe, V. M. H.
    De Ruysscher, D.
    Lambin, P.
    Oberije, C.
    Uyl-de Groot, C. A.
    [J]. VALUE IN HEALTH, 2013, 16 (07) : A414 - A414
  • [23] Aspects of simulator cone-beam CT for radiotherapy treatment planning
    Irvine, Denise
    McJury, Mark
    [J]. JOURNAL OF RADIOTHERAPY IN PRACTICE, 2010, 9 (03) : 165 - 174
  • [24] Investigation of cone-beam CT for breast cancer treatment planning
    Kim, G
    Horst, K
    Maxim, P
    Luxton, G
    Xing, L
    Boyer, AL
    Pawlicki, T
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2005, 63 (02): : S553 - S553
  • [25] AN ELECTRON-DENSITY CALIBRATION PHANTOM FOR CT-BASED TREATMENT PLANNING COMPUTERS
    CONSTANTINOU, C
    HARRINGTON, JC
    DEWERD, LA
    [J]. MEDICAL PHYSICS, 1992, 19 (02) : 325 - 327
  • [26] IMPACT OF CT-BASED TREATMENT PLANNING ON RADIATION-THERAPY OF CARCINOMA OF THE BLADDER
    BENTZEN, SM
    JESSEN, KA
    JORGENSEN, J
    SELL, A
    [J]. ACTA RADIOLOGICA ONCOLOGY, 1984, 23 (2-3): : 199 - 203
  • [27] Uncertainties in CT-based radiation therapy treatment planning associated with patient breathing
    Balter, JM
    TenHaken, RK
    Lawrence, TS
    Lam, KL
    Robertson, JM
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1996, 36 (01): : 167 - 174
  • [28] Quantitative image quality evaluation for kV cone-beam CT-based IGRT
    Lim, S. Y.
    Zin, Hafiz M.
    [J]. 10TH INTERNATIONAL SEMINAR ON MEDICAL PHYSICS & 1ST AMDI INTERNATIONAL ONCOLOGY SYMPOSIUM, 2017, 851
  • [29] DOSIMETRIC IMPACT OF ONLINE CORRECTION VIA CONE-BEAM CT-BASED IMAGE GUIDANCE FOR STEREOTACTIC LUNG RADIOTHERAPY
    Galerani, Ana Paula
    Grills, Inga
    Hugo, Geoffrey
    Kestin, Larry
    Mohammed, Nasiruddin
    Chao, K. Kenneth
    Suen, Andrew
    Martinez, Alvaro
    Yan, Di
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2010, 78 (05): : 1571 - 1578
  • [30] Comparison of intraoperative CT- and cone beam CT-based spinal navigation for the treatment of atlantoaxial instability
    Haemmerli, Julien
    Ferdowssian, Kiarash
    Wessels, Lars
    Mertens, Robert
    Hecht, Nils
    Woitzik, Johannes
    Schneider, Ulf C.
    Bayerl, Simon H.
    Vajkoczy, Peter
    Czabanka, Marcus
    [J]. SPINE JOURNAL, 2023, 23 (12): : 1799 - 1807