Aspects of simulator cone-beam CT for radiotherapy treatment planning

被引:0
|
作者
Irvine, Denise [1 ]
McJury, Mark [1 ]
机构
[1] Belfast HSC Trust, Reg Med Phys Serv, Lisburn Rd, Belfast BT9 7AB, Antrim, North Ireland
关键词
cone-beam CT; simulation; DRRs; CT numbers; Hounsfield numbers; image quality;
D O I
10.1017/S1460396910000026
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background and purpose: Following a recent major upgrade in cone-beam computed tomography (CBCT) software and functionality, we have reassessed aspects of our Varian Acuity simulator performance for use in treatment planning. The feasibility of using CBCT for treatment planning has been assessed and here we report specifically on Hounsfield number (HN) accuracy and related dose errors, and digitally reconstructed radiograph (DRR) image quality. Methods: Using a Catphan (R) 600 CT phantom, HN accuracy and uniformity were investigated for a range of CBCT imaging modes. This included the variation in HNs with scan length and phantom position. Results were compared with those acquired from conventional CT. Treatment plans for three sites were generated using the Rando phantom, and results from CBCT-based data were compared to that from CT-based data using a gamma analysis. Image quality of DRRs based on CBCT data were compared with those from CT data both quantitatively, by calculating the modulation transfer function (MTF) and qualitatively, by counting the number of line pairs visible on a phantom. Results and conclusions: Catphan data showed that for certain cases, the HN calibration of the Acuity CBCT was out of tolerance and could lead to errors in dose calculation of >2%. HNs were only acceptable for scan lengths >10 cm. In multi-scan mode, geometric shifts and differences in HNs were seen on CT slices on either side of the interface between the two acquisitions. However, comparisons between treatment plans calculated using CBCT data and conventional CT data from Rando phantoms showed that head, pelvis and thorax plans were acceptable. CBCT DRR image quality compared favourably with a conventional CT scanner in some respects; however, image uniformity and low contrast resolution were poorer due to the 'cupping' artefact obtained with CBCT scans.
引用
收藏
页码:165 / 174
页数:10
相关论文
共 50 条
  • [1] Evaluation of simulator cone beam CT images for radiotherapy treatment planning
    Menon, G. V.
    Dunscombe, P.
    Tambasco, M.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2006, 66 (03): : S689 - S689
  • [2] Feasibility of Cone-beam CT based treatment planning
    Yoo, S.
    Yin, F.
    [J]. WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING 2006, VOL 14, PTS 1-6, 2007, 14 : 1831 - 1834
  • [3] Feasibility of cone-beam CT based treatment planning
    Yoo, S.
    Yin, F.
    [J]. MEDICAL PHYSICS, 2006, 33 (06) : 2219 - 2219
  • [4] Cone-beam CT for radiotherapy applications
    Cho, P.S.
    Johnson, R.H.
    Griffin, T.W.
    [J]. 1863, Institute of Physics Publishing Ltd, Bristol, Engl (40):
  • [5] CONE-BEAM CT FOR RADIOTHERAPY APPLICATIONS
    CHO, PS
    JOHNSON, RH
    GRIFFIN, TW
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 1995, 40 (11): : 1863 - 1883
  • [6] Investigation of cone-beam CT for breast cancer treatment planning
    Kim, G
    Horst, K
    Maxim, P
    Luxton, G
    Xing, L
    Boyer, AL
    Pawlicki, T
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2005, 63 (02): : S553 - S553
  • [7] Use of cone beam CT in a simulator for radiotherapy planning of early glottis cancer
    Lee, L.
    Ho, K.
    Yap, B.
    Sykes, A.
    Slevin, N.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2007, 82 : S43 - S43
  • [8] Application of asymmetric cone-beam CT in radiotherapy
    Yu, LF
    Pelizzari, C
    Pan, XC
    Riem, H
    Munro, P
    Kaissl, W
    [J]. 2004 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-7, 2004, : 3249 - 3252
  • [9] A cone-beam megavoltage CT scanner for treatment verification in conformal radiotherapy
    Mosleh-Shirazi, MA
    Evans, PM
    Swindell, W
    Webb, S
    Partridge, M
    [J]. RADIOTHERAPY AND ONCOLOGY, 1998, 48 (03) : 319 - 328
  • [10] Dose assessment for daily cone-beam CT in lung radiotherapy patients and its combination with treatment planning
    Hassan Albarakati
    Price Jackson
    Okan Gulal
    Prabhakar Ramachandran
    Glen Osbourne
    Michael Liu
    Tomas Kron
    Moshi Geso
    [J]. Physical and Engineering Sciences in Medicine, 2022, 45 : 231 - 237