Feasibility of Cone-beam CT based treatment planning

被引:0
|
作者
Yoo, S. [1 ]
Yin, F. [1 ]
机构
[1] Duke Univ, Med Ctr, Dept Radiat Oncol, Durham, NC 27710 USA
关键词
Treatment planning; Cone-beam CT; HU values; dose calculation;
D O I
暂无
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Purpose: This study investigates feasibility of CBCT-based treatment planning. Methods and materials: Hounsfield unit (HU) values and profiles of phantoms and patients in CBCT images were compared to those in CT images. CBCT-based treatment plans for the phantoms and patients were compared to CT-based treatment plans dosimetrically. Results: Mean HU values of different materials in CBCT images were very close to those in CT images for Catphan. CBCT images included scatters and artifacts. As a consequent, the HU profiles of the homogeneous phantoms in CBCT images showed inhomogeneous HU distribution and the peripheral areas near the edge of the field-of-view showed reduced HU values. The HU profiles of the inhomogeneous phantom showed reduced HU values throughout the phantom and more significantly around the peripheral areas and lungs than other areas. The HU values in patients were also reduced in most tissue regions in CBCT images. Most plans based on CBCT with a bowtie filter showed good agreement with those based on CT with less than 1 % of MU/cGy difference or 1 - 2 mm of isodose discrepancy. Large dosimetrical discrepancy occurred when CBCT was scanned without a bowtie filter, when a treatment beam passed through a significant amount of lung, and when a treatment beam was largely off-centered so as to pass through a body part imaged near the edge of the field-of-view. All IMRT plans based on CBCT and CT showed isodose distribution with very good agreement for patient cases except for one lung cancer patient. Conclusion: This study proves feasibility of CBCT-based treatment planning by comparing HU values, MU/cGy and isodose distributions to the gold standard CT-based treatment planning. CBCT could he used for treatment planning purposes for most cases except for the cases with large discrepancy shown in this study.
引用
收藏
页码:1831 / 1834
页数:4
相关论文
共 50 条
  • [1] Feasibility of cone-beam CT based treatment planning
    Yoo, S.
    Yin, F.
    [J]. MEDICAL PHYSICS, 2006, 33 (06) : 2219 - 2219
  • [2] Dosimetric feasibility of cone-beam CT-based treatment planning compared to CT-based treatment planning
    Yoo, Sua
    Yin, Fang-Fang
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2006, 66 (05): : 1553 - 1561
  • [3] Preliminary Investigation of Cone-Beam CT Post-Planning Feasibility
    Juhasz, J.
    Wierzbicki, M.
    [J]. MEDICAL PHYSICS, 2011, 38 (06)
  • [4] Aspects of simulator cone-beam CT for radiotherapy treatment planning
    Irvine, Denise
    McJury, Mark
    [J]. JOURNAL OF RADIOTHERAPY IN PRACTICE, 2010, 9 (03) : 165 - 174
  • [5] Investigation of cone-beam CT for breast cancer treatment planning
    Kim, G
    Horst, K
    Maxim, P
    Luxton, G
    Xing, L
    Boyer, AL
    Pawlicki, T
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2005, 63 (02): : S553 - S553
  • [6] Cone beam CT based treatment planning
    Paliwal, B.
    Tewatia, D.
    Orton, N.
    Tome, W.
    Basavatia, A.
    [J]. MEDICAL PHYSICS, 2006, 33 (06) : 2029 - 2029
  • [7] Does cone-beam CT alter treatment plans? Comparison of preoperative implant planning using panoramic versus cone-beam CT images
    Guerrero, Maria Eugenia
    Noriega, Jorge
    Castro, Carmen
    Jacobs, Reinhilde
    [J]. IMAGING SCIENCE IN DENTISTRY, 2014, 44 (02) : 121 - 128
  • [8] FEASIBILITY OF CONTRAST ENHANCED CONE-BEAM CT FOR TARGET LOCALIZATION AND TREATMENT MONITORING
    Rodal, J.
    Soevik, A.
    Kippernes, H.
    Knudtsen, I. S.
    Malinen, E.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2010, 96 : S433 - S433
  • [9] Are planning CT radiomics and cone-beam CT radiomics interchangeable?
    Van Timmeren, J. E.
    Leijenaar, R. T. H.
    Van Elmpt, W.
    Lambin, P.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2016, 119 : S446 - S447
  • [10] Feasibility of Using the Planning CT (pCT) Electron Density Calibration Curve for Prostate Cancer Adaptive Planning Based On Daily Cone-Beam CT
    Shukla, P.
    Mynampati, D.
    Brodin, P.
    Lukaj, A.
    Yaparpalvi, R.
    Basavatia, A.
    Tome, W.
    [J]. MEDICAL PHYSICS, 2022, 49 (06) : E725 - E725