Technical Note: Patient-weight dependence of the effective dose conversion coefficients for diagnostic x-ray imaging procedures

被引:0
|
作者
Golikov, Vladislav [1 ]
Druzhinina, Polina [1 ]
机构
[1] St Petersburg Res Inst Radiat Hyg, Mira Str 8, St Petersburg 197101, Russia
关键词
conversion coefficients; effective dose; patients; x-ray examination; PEDIATRIC BARIUM MEAL; COMPUTATIONAL PHANTOMS; ORGAN; ADULT; AGE;
D O I
10.1002/mp.14446
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose The aim of this study was to provide a method and reference data for the evaluation of the weight dependence of the conversion coefficients from air collision kerma integrated over beam area to the effective dose for patients undergoing diagnostic x-ray examinations. Method A simple physics-based analytical model was developed in order to calculate the weight dependence of the effective dose conversion coefficients based on existing values of the conversion coefficients between patient effective dose and air collision kerma integrated over beam area calculated by the Monte Carlo method on the base of computational MIRD-5-type stylized models. Results The analytical expressions that make possible taking into account a patient's weight when assessing the effective dose were presented. The following categories of diagnostic x-ray examinations are considered: CT; plain radiography; cardiac angiography; fluoroscopy. The results indicate that the weight dependence of the effective dose conversion coefficients for different categories of diagnostic x-ray examinations has the same form. Correction factor for evaluation of the new value of the effective dose conversion coefficient for a patient with weightW(pa.)when we know its value for a standard patient with weightW(st.)depends on the ratios of their weights (W-st./W-pat.) and fractions of the incident energy which is imparted to a patient. Conclusions The paper presents an approach and necessary data for the estimation of the weight dependence of the effective dose conversion coefficients for patients undergoing different diagnostic x-ray examinations.
引用
收藏
页码:5366 / 5372
页数:7
相关论文
共 50 条
  • [1] Technical Note: Patient-weight dependence of the effective dose conversion coefficients for diagnostic x-ray imaging procedures
    Golikov, Vladislav
    Druzhinina, Polina
    MEDICAL PHYSICS, 2020, 47 (10) : 5366 - 5372
  • [2] Technical Note: Patient-weight dependence of the effective dose conversion coefficients for diagnostic x-ray imaging procedures
    Golikov, Vladislav
    Druzhinina, Polina
    Medical Physics, 2020, 47 (10): : 5366 - 5372
  • [3] THE DOSE TO OPERATOR AND PATIENT IN X-RAY DIAGNOSTIC PROCEDURES .2.
    ARDRAN, GM
    BRITISH JOURNAL OF RADIOLOGY, 1956, 29 (341): : 266 - 269
  • [4] Technical Note: Nanometric organic photovoltaic thin film detectors for dose monitoring in diagnostic x-ray imaging
    Elshahat, Bassem
    Gill, Hardeep Singh
    Filipyev, Ilya
    Shrestha, Suman
    Hesser, Juergen
    Kumar, Jayant
    Karellas, Andrew
    Zygmanski, Piotr
    Sajo, Erno
    MEDICAL PHYSICS, 2015, 42 (07) : 4027 - 4032
  • [5] METHODS OF DOSE REDUCTION IN DIAGNOSTIC X-RAY PROCEDURES
    BROWN, RF
    PHYSICS IN MEDICINE AND BIOLOGY, 1972, 17 (01): : 138 - &
  • [6] Characterization of amorphous thermoluminescence dosimeters for patient dose measurement in X-ray diagnostic procedures
    Ramli, N. N. H.
    Salleh, H.
    Mahdiraji, G. A.
    Zulkifli, M. I.
    Hashim, S.
    Bradley, D. A.
    Noor, N. M.
    RADIATION PHYSICS AND CHEMISTRY, 2015, 116 : 130 - 134
  • [7] PATIENT DOSE FROM SELECTED X-RAY PROCEDURES
    AGARWAL, SK
    BERK, HW
    HEALTH PHYSICS, 1986, 50 : S53 - S53
  • [8] GONADAL EXPOSURE DOSE FROM DIAGNOSTIC X-RAY PROCEDURES
    FELDMAN, A
    BABCOCK, GC
    LANIER, RR
    MORKOVIN, D
    RADIOLOGY, 1958, 71 (02) : 197 - 207
  • [9] Conversion coefficients for estimation of effective dose to patients from dose area product during fluoroscopy X-ray examinations
    Gosch, D.
    Gosch, K.
    Kahn, T.
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2007, 179 (10): : 1035 - 1042
  • [10] Conversion coefficients from kerma to ambient dose and personal dose for X-ray spectra
    Otto, T.