Potentiometric detection of carboxylic acids by flow injection analysis using a tungsten oxide electrode

被引:14
|
作者
Chen, ZL
Alexander, PW
机构
[1] Department of Physical Science, Univ. of Tasmania at Launceston, Launceston, Tasmania 7250
关键词
flow injection; carboxylic acids; tungsten oxide electrode; potentiometry;
D O I
10.1016/0003-2670(96)00258-9
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Potentiometric flow injection (PFI) analysis of carboxylic acids based on a tungsten oxide electrode is described. The electrode is shown to offer high sensitivity and a stable baseline for the detection of carboxylic acids. The parameters affecting the electrode response such as the concentration of buffer, the pH and flow rate were studied in detail. The electrode exhibited a linear response for propionic acid in the concentration range of 2.5x10(-4)M-5x10(-5)M using a 5x10(-4)M phosphate buffer at pH 6.5 as a carrier. The detection limits were found to be in the range of 1.0x10(-5)M-5x10(-5)M with a 20 mu l injection.
引用
收藏
页码:187 / 192
页数:6
相关论文
共 50 条
  • [21] FLOW-INJECTION DETERMINATION OF DRUGS BY SPECIFIC DETECTION OF CARBOXYLIC-ACIDS
    TAKEUCHI, T
    KABASAWA, Y
    HORIKAWA, R
    TANIMURA, T
    ANALYST, 1988, 113 (11) : 1673 - 1675
  • [22] Gas diffusion-flow injection determination of total inorganic carbon in water using tungsten oxide electrode
    Monser, L
    Adhoum, N
    Sadok, S
    TALANTA, 2004, 62 (02) : 389 - 394
  • [23] Determination of SO2 in wines using a flow injection analysis system with potentiometric detection
    Araújo, AN
    Couto, CMCM
    Lima, JLFC
    Montenegro, MCBSM
    JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 1998, 46 (01) : 168 - 172
  • [24] A tungsten oxide coated wire electrode used as a pH sensor in flow injection potentiometry
    Dimitrakopoulos, LT
    Dimitrakopoulos, T
    Alexander, PW
    Logic, D
    Hibbert, DB
    ANALYTICAL COMMUNICATIONS, 1998, 35 (12): : 395 - 398
  • [25] Detection of catechol by potentiometric-flow injection analysis in the presence of interferents
    Lunsford, Suzanne K.
    Widera, Justyna
    Zhang, Hong
    JOURNAL OF CHEMICAL EDUCATION, 2007, 84 (09) : 1471 - 1473
  • [26] Determination of Nitrate in Leafy Vegetables by Flow Injection Analysis with Potentiometric Detection
    Andac, Muberra
    Eren, Hilal
    Coldur, Fatih
    JOURNAL OF FOOD AND DRUG ANALYSIS, 2011, 19 (04) : 457 - 462
  • [27] POROUS LAYER FLOW-INJECTION ANALYSIS WITH POTENTIOMETRIC CHLORIDE DETECTION
    YIN, Q
    HUBER, CO
    TALANTA, 1994, 41 (10) : 1771 - 1774
  • [28] Determination of Dipyrone in Pharmaceutical Products by Flow Injection Analysis with Potentiometric Detection
    Jackson S. Albuquerque
    Valdinete L. Silva
    Fernando Lima
    Alberto N. Araújo
    Maria Conceição B. S. M. Montenegro
    Analytical Sciences, 2003, 19 : 691 - 694
  • [29] Potentiometric Determination of Sibutramine Using Batch and Flow Injection Analysis
    El Gohary, Nesrine A.
    El Nashar, Rasha M.
    Aboul-Enien, Hassan Y.
    ANALYTICAL LETTERS, 2011, 44 (1-3) : 241 - 257
  • [30] Determination of dipyrone in pharmaceutical products by flow injection analysis with potentiometric detection
    Albuquerque, JS
    Silva, VL
    Lima, F
    Araújo, AN
    Montenegro, MCBSM
    ANALYTICAL SCIENCES, 2003, 19 (05) : 691 - 694