This paper describes the development and application of a flow injection analysis system manifold comprising a gas diffusion unit and a potentiometric detector to the determination of free and total SO2 in white and red wines. A homogeneous crystalline iodide double-membrane tubular electrode was used as detector. SO2 determination based on the Ripper method was carried out by dosing the iodide formed in the oxidation of SO2 with iodine, followed by the separation of the formed compound through a diffusion Teflon membrane. The results obtained from the analyses of free and total SO2 in 30 wine samples showed good agreement between the proposed method and the rapid assay method recommended by the UE and OIV. The relative error deviations of the results obtained by both methods were <6%. This procedure is suitable for samples with similar to 3.2-180 mg L-1 SO2, performing determinations of 75-100 samples h(-1).
引用
收藏
页码:168 / 172
页数:5
相关论文
共 50 条
  • [1] Determination of orciprenaline using a flow injection analysis system with sequential potentiometric and spectrophotometric detection
    El Nashar, Rasha Mohamed
    ANALYTICAL LETTERS, 2008, 41 (06) : 949 - 964
  • [2] DETERMINATION OF SO2 IN WINES USING GAS ELECTRODES WITH AIR CLEARANCE
    ARUTYUNYAN, AN
    TURYAN, YI
    IZVESTIYA VYSSHIKH UCHEBNYKH ZAVEDENII PISHCHEVAYA TEKHNOLOGIYA, 1984, (01): : 71 - 74
  • [3] Determination of chloride by multisyringe flow injection analysis and sequential injection analysis with potentiometric detection
    Andrade-Eiroa, A
    Erustes, JA
    Forteza, R
    Cerdá, V
    Lima, JLFC
    ANALYTICA CHIMICA ACTA, 2002, 467 (1-2) : 25 - 33
  • [4] Flow injection system with potentiometric detection for the determination of urea content in milks
    Lima, JLFC
    Delerue-Matos, C
    Vaz, MCVF
    JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 1998, 46 (04) : 1386 - 1389
  • [5] Potentiometric Determination of Sibutramine Using Batch and Flow Injection Analysis
    El Gohary, Nesrine A.
    El Nashar, Rasha M.
    Aboul-Enien, Hassan Y.
    ANALYTICAL LETTERS, 2011, 44 (1-3) : 241 - 257
  • [6] Determination of total nitrogen in food by flow injection analysis (FIA) with a potentiometric differential detection system
    José L. F. C. Lima
    M. C. B. S. M. Montenegro
    Ana P. M. M. O. Pinto
    Fresenius' Journal of Analytical Chemistry, 1999, 364 : 353 - 357
  • [7] Determination of Nitrate in Leafy Vegetables by Flow Injection Analysis with Potentiometric Detection
    Andac, Muberra
    Eren, Hilal
    Coldur, Fatih
    JOURNAL OF FOOD AND DRUG ANALYSIS, 2011, 19 (04) : 457 - 462
  • [8] Determination of Dipyrone in Pharmaceutical Products by Flow Injection Analysis with Potentiometric Detection
    Jackson S. Albuquerque
    Valdinete L. Silva
    Fernando Lima
    Alberto N. Araújo
    Maria Conceição B. S. M. Montenegro
    Analytical Sciences, 2003, 19 : 691 - 694
  • [9] Determination of dipyrone in pharmaceutical products by flow injection analysis with potentiometric detection
    Albuquerque, JS
    Silva, VL
    Lima, F
    Araújo, AN
    Montenegro, MCBSM
    ANALYTICAL SCIENCES, 2003, 19 (05) : 691 - 694
  • [10] Determination of total nitrogen in food by flow injection analysis (FIA) with a potentiometric differential detection system
    Lima, JLFC
    Montenegro, MCBSM
    Pinto, APMMO
    FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1999, 364 (04): : 353 - 357