Determination of SO2 in wines using a flow injection analysis system with potentiometric detection

被引:46
|
作者
Araújo, AN [1 ]
Couto, CMCM [1 ]
Lima, JLFC [1 ]
Montenegro, MCBSM [1 ]
机构
[1] Fac Farm UP, Dept Quim Fis, CEQUP, P-4050 Porto, Portugal
关键词
SO2; flow injection analysis; wines; tubular electrode; increased sensitivity;
D O I
10.1021/jf970354i
中图分类号
S [农业科学];
学科分类号
09 ;
摘要
This paper describes the development and application of a flow injection analysis system manifold comprising a gas diffusion unit and a potentiometric detector to the determination of free and total SO2 in white and red wines. A homogeneous crystalline iodide double-membrane tubular electrode was used as detector. SO2 determination based on the Ripper method was carried out by dosing the iodide formed in the oxidation of SO2 with iodine, followed by the separation of the formed compound through a diffusion Teflon membrane. The results obtained from the analyses of free and total SO2 in 30 wine samples showed good agreement between the proposed method and the rapid assay method recommended by the UE and OIV. The relative error deviations of the results obtained by both methods were <6%. This procedure is suitable for samples with similar to 3.2-180 mg L-1 SO2, performing determinations of 75-100 samples h(-1).
引用
收藏
页码:168 / 172
页数:5
相关论文
共 50 条
  • [21] Application Of A Potentiometric Electronic Tongue For The Determination Of Free SO2 And Other Analytical Parameters In White Wines From New Zealand
    Mednova, Olga
    Kirsanov, Dmitry
    Rudnitskaya, Alisa
    Kilmartin, Paul
    Legin, Andrey
    OLFACTION AND ELECTRONIC NOSE, PROCEEDINGS, 2009, 1137 : 263 - +
  • [22] Potentiometric determination of chloride in vegetables by flow injection analysis
    Lima, JLFC
    Rangel, AOSS
    Souto, MRS
    COMMUNICATIONS IN SOIL SCIENCE AND PLANT ANALYSIS, 1996, 27 (1-2) : 37 - 46
  • [23] The determination of mercaptoacetic acid by using a flow injection system analysis with chemiluminometric detection
    Cheregi, MC
    Badea, M
    Danet, AF
    REVISTA DE CHIMIE, 2003, 54 (05): : 383 - 385
  • [24] Flow injection system for potentiometric determination of alkaline phosphatase inhibitors
    Koncki, Robert
    Rudnicka, Katarzyna
    Tymecki, Lukasz
    ANALYTICA CHIMICA ACTA, 2006, 577 (01) : 134 - 139
  • [25] DETERMINATION OF METALLIC CATIONS IN WINES BY FLOW-INJECTION ANALYSIS
    LIMA, JLFC
    RANGEL, AOSS
    AMERICAN JOURNAL OF ENOLOGY AND VITICULTURE, 1990, 41 (04): : 284 - 288
  • [26] Flow injection potentiometric determination of chlorpromazine
    Sales, MGF
    Tomás, JFC
    Lavandeira, SR
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2006, 41 (04) : 1280 - 1286
  • [27] Potentiometric flow injection determination of salbutamol
    Abdel-Ghani, NT
    Rizk, MS
    El-Nashar, RM
    ANALYTICAL LETTERS, 2002, 35 (01) : 39 - 52
  • [28] Flow injection potentiometric determination of reproterol
    Issa, YM
    Rizk, MS
    El-Nashar, RM
    QUIMICA ANALITICA, 2001, 20 (03): : 159 - 163
  • [29] FLOW-INJECTION DETERMINATION OF COPPER IN CONCENTRATED ELECTROLYTES WITH POTENTIOMETRIC DETECTION
    KRAWCZYK, TKV
    TROJANOWICZ, M
    HULANICKI, A
    CHEMIA ANALITYCZNA, 1988, 33 (01): : 69 - 74
  • [30] Determination of L-asparagine using flow-injection systems with spectrophotometric and potentiometric detection
    Stein, K
    Shi, RB
    Schwedt, G
    ANALYTICA CHIMICA ACTA, 1996, 336 (1-3) : 113 - 122