Detection of protein S deficiency: A new functional assay compared to an antigenic technique

被引:3
|
作者
Moraes, C
Lofthouse, E
Eikelboom, J
Thom, J
Baker, R
机构
[1] Univ Western Australia, Royal Perth Hosp, Coagulat Unit, Perth, WA 6000, Australia
[2] McMaster Univ, Prevent Cardiol & Therapeut Program, Hamilton, ON, Canada
关键词
protein S; clotting based kit; protein S deficiency; thrombophilia; automation;
D O I
10.1080/003130200104303
中图分类号
R36 [病理学];
学科分类号
100104 ;
摘要
Congenital protein S (PS) deficiency is associated with increased risk of venous thrombosis. To investigate the possibility of automating PS testing with decreased turnaround time, a clotting-based functional protein S assay was evaluated and compared to an antigenic method. Samples were collected from 126 patients within 5 days of their first acute cerebral infarction, from 62 controls and from 47 consecutive samples for thrombophilia investigation. The normal range for the clotting-based kit, calculated from the results of 20 healthy controls, was 62-136% (mean +/- 2 SD). Intra- and inter-assay co-efficients of variation were <3.0 and 10.0%, respectively. There was no significant correlation between the two methods (r = 0.30, P > 0.05). Two patients had low PS antigen results with normal functional levels. Both techniques were used to compare a further group of 53 patients with defined abnormalities which included nine antigenic protein S deficiencies, five protein C deficient patients, 10 patients with a lupus anticoagulant (LA), 17 Factor V Leiden (FVL) heterozygotes, two FVL homozygotes and 10 patients on therapeutic levels of heparin. In this group we found that four of nine antigenic PS deficient patients had normal functional PS levels. The test was susceptible to the FVL mutation with four of 17 FVL heterozygotes and both of two FVL homozygotes giving low levels. One of five protein C-deficient patients also had a low functional PS result with a normal antigenic level. Normal results were obtained by both methods for all of the LA and patients on therapeutic heparin, We concluded that the automated protein S clotting assay was rapid and simple to perform but appeared to be influenced by factors other than PS deficiency. Results need to be interpreted with caution but may be useful as part of a full thrombophilia investigation.
引用
收藏
页码:94 / 97
页数:4
相关论文
共 50 条
  • [41] PARTICLE AGGLUTINATION ASSAY - A NEW TECHNIQUE FOR THE DETECTION OF HIV-1 ANTIBODIES
    MULLER, F
    GROMM, M
    MULLER, KH
    IMMUNITAT UND INFEKTION, 1988, 16 (04): : 148 - 151
  • [42] Chromism-based assay (CHROBA) technique for in situ detection of protein kinase activity
    Tomizaki, KY
    Mihara, H
    BIOPOLYMERS, 2005, 80 (04) : 545 - 545
  • [43] A chromism-based assay (CHROBA) technique for in situ detection of protein kinase activity
    Tomizaki, KY
    He, X
    Mihara, H
    BIOORGANIC & MEDICINAL CHEMISTRY LETTERS, 2005, 15 (06) : 1731 - 1735
  • [44] ANOTHER PROTEIN-S FUNCTIONAL ASSAY IS SENSITIVE TO RESISTANCE TO ACTIVATED PROTEIN-C
    FAIONI, EM
    BOYERNEUMANN, C
    FRANCHI, F
    WOLF, M
    MEYER, D
    MANNUCCI, PM
    THROMBOSIS AND HAEMOSTASIS, 1994, 72 (04) : 648 - 648
  • [45] HETEROZYGOTE DETECTION IN INHERITED PROTEIN-S DEFICIENCY BY GENE ANALYSIS
    VANAMSTEL, HKP
    HAMULYAK, K
    DEDIESMULDERS, CEM
    REITSMA, PH
    BERTINA, RM
    ARTERIOSCLEROSIS, 1988, 8 (05): : A684 - A684
  • [46] DETECTION OF FUNCTIONAL IRON-DEFICIENCY DURING ERYTHROPOIETIN TREATMENT - A NEW APPROACH
    MACDOUGALL, IC
    CAVILL, I
    HULME, B
    BAIN, B
    MCGREGOR, E
    MCKAY, P
    SANDERS, E
    COLES, GA
    WILLIAMS, JD
    BRITISH MEDICAL JOURNAL, 1992, 304 (6821): : 225 - 226
  • [47] Detection of alloreactive T cells by flow cytometry: A new test compared with limiting dilution assay
    de Haan, A
    van der Gun, I
    van der Bij, W
    de Leij, LFMH
    Prop, J
    TRANSPLANTATION, 2002, 74 (04) : 562 - 570
  • [48] Adaptation of a functional assay for protein S to a Cobas Fara II centrifugal analyzer
    Solomon, HM
    Simmons, VL
    Randall, JR
    AMERICAN JOURNAL OF CLINICAL PATHOLOGY, 1995, 104 (06) : 655 - 659
  • [49] FUNCTIONAL ASSAY OF PROTEIN-S IN 70 PATIENTS WITH CONGENITAL AND ACQUIRED DISORDERS
    WOLF, M
    BOYERNEUMANN, C
    LEROYMATHERON, C
    MARTINOLI, JL
    CONTANT, G
    AMIRAL, J
    MEYER, D
    LARRIEU, MJ
    BLOOD COAGULATION & FIBRINOLYSIS, 1991, 2 (06) : 705 - 712
  • [50] ImmunoCard STAT! cartridge antigen detection assay compared to microplate enzyme immunoassay and modified Kinyoun's acid-fast staining technique for detection of Cryptosporidium in fecal specimens
    Amal Abdul-rasheed El-Moamly
    Mohamed Aly El-Sweify
    Parasitology Research, 2012, 110 : 1037 - 1041