Detection of protein S deficiency: A new functional assay compared to an antigenic technique

被引:3
|
作者
Moraes, C
Lofthouse, E
Eikelboom, J
Thom, J
Baker, R
机构
[1] Univ Western Australia, Royal Perth Hosp, Coagulat Unit, Perth, WA 6000, Australia
[2] McMaster Univ, Prevent Cardiol & Therapeut Program, Hamilton, ON, Canada
关键词
protein S; clotting based kit; protein S deficiency; thrombophilia; automation;
D O I
10.1080/003130200104303
中图分类号
R36 [病理学];
学科分类号
100104 ;
摘要
Congenital protein S (PS) deficiency is associated with increased risk of venous thrombosis. To investigate the possibility of automating PS testing with decreased turnaround time, a clotting-based functional protein S assay was evaluated and compared to an antigenic method. Samples were collected from 126 patients within 5 days of their first acute cerebral infarction, from 62 controls and from 47 consecutive samples for thrombophilia investigation. The normal range for the clotting-based kit, calculated from the results of 20 healthy controls, was 62-136% (mean +/- 2 SD). Intra- and inter-assay co-efficients of variation were <3.0 and 10.0%, respectively. There was no significant correlation between the two methods (r = 0.30, P > 0.05). Two patients had low PS antigen results with normal functional levels. Both techniques were used to compare a further group of 53 patients with defined abnormalities which included nine antigenic protein S deficiencies, five protein C deficient patients, 10 patients with a lupus anticoagulant (LA), 17 Factor V Leiden (FVL) heterozygotes, two FVL homozygotes and 10 patients on therapeutic levels of heparin. In this group we found that four of nine antigenic PS deficient patients had normal functional PS levels. The test was susceptible to the FVL mutation with four of 17 FVL heterozygotes and both of two FVL homozygotes giving low levels. One of five protein C-deficient patients also had a low functional PS result with a normal antigenic level. Normal results were obtained by both methods for all of the LA and patients on therapeutic heparin, We concluded that the automated protein S clotting assay was rapid and simple to perform but appeared to be influenced by factors other than PS deficiency. Results need to be interpreted with caution but may be useful as part of a full thrombophilia investigation.
引用
收藏
页码:94 / 97
页数:4
相关论文
共 50 条
  • [31] A functional assay for detection of the mitoxantrone resistance protein, MXR (ABCG2)
    Robey, RW
    Honjo, Y
    van de Laar, A
    Miyake, K
    Regis, JT
    Litman, T
    Bates, SE
    BIOCHIMICA ET BIOPHYSICA ACTA-BIOMEMBRANES, 2001, 1512 (02): : 171 - 182
  • [32] Sensitivity of functional protein S assays to protein S deficiency: a comparative study of three commercial kits
    Jennings, I
    Kitchen, S
    Cooper, P
    Makris, M
    Preston, FE
    JOURNAL OF THROMBOSIS AND HAEMOSTASIS, 2003, 1 (05) : 1112 - 1114
  • [33] A PROTHROMBIN TIME-BASED FUNCTIONAL ASSAY OF PROTEIN-S
    PREDA, L
    TRIPODI, A
    VALSECCHI, C
    LOMBARDI, A
    FINOTTO, E
    MANNUCCI, PM
    THROMBOSIS RESEARCH, 1990, 60 (01) : 19 - 32
  • [34] ANTICARDIOLIPIN ANTIBODIES, FUNCTIONAL PROTEIN-S DEFICIENCY, AND FETAL LOSS
    RUFFATTI, A
    DILENARDO, L
    SIMIONI, P
    TONETTO, S
    GIROLAMI, A
    GRELLA, P
    TODESCO, S
    AMERICAN JOURNAL OF HEMATOLOGY, 1995, 48 (01) : 65 - 66
  • [35] An improved screening system for protein S type II deficiency: expanded versatility of total protein S activity assay
    Tomohide, T.
    Xiuri, J.
    Hiroko, T.
    Naotaka, H.
    JOURNAL OF THROMBOSIS AND HAEMOSTASIS, 2013, 11 : 603 - 603
  • [36] A NEW FUNCTIONAL ASSAY FOR HUMAN PROTEIN-S ACTIVITY USING ACTIVATED FACTOR-V AS SUBSTRATE
    WOLF, M
    BOYERNEUMANN, C
    MARTINOLI, JL
    LEROYMATHERON, C
    AMIRAL, J
    MEYER, D
    LARRIEU, MJ
    THROMBOSIS AND HAEMOSTASIS, 1989, 62 (04) : 1144 - 1145
  • [37] NEW TECHNIQUE FOR DETECTION OF IMMUNOGLOBULINS BY IMMUNOFLUORESCENCE - VALUES OF CLASSICAL FIXATION AND OF CONGELATION COMPARED
    SONSINO, E
    PELLETIER, M
    FERLET, C
    BOCQUET, L
    NOUVELLE PRESSE MEDICALE, 1975, 4 (08): : 575 - 576
  • [38] Feasibility studies on a protein kinase assay when using radioisotope detection technique for developing a protein biochip
    Park, Sang Hyun
    Ko, Kyong-Cheol
    Gwon, Hui Jeong
    JOURNAL OF LABELLED COMPOUNDS & RADIOPHARMACEUTICALS, 2007, 50 (7-8): : 724 - 728
  • [39] THE USE OF A FUNCTIONAL AND IMMUNOLOGICAL ASSAY FOR PLASMA PROTEIN-C IN THE STUDY OF THE HETEROGENEITY OF CONGENITAL PROTEIN-C DEFICIENCY
    BERTINA, RM
    BROEKMANS, AW
    KROMMENHOEKVANES, C
    VANWIJNGAARDEN, A
    THROMBOSIS AND HAEMOSTASIS, 1984, 51 (01) : 1 - 5
  • [40] A NEW VERSION OF THE 2-HYBRID ASSAY FOR DETECTION OF PROTEIN-PROTEIN INTERACTIONS
    LEDOUARIN, B
    PIERRAT, B
    BAUR, EV
    CHAMBON, P
    LOSSON, R
    NUCLEIC ACIDS RESEARCH, 1995, 23 (05) : 876 - 878