Theoretical evaluation of accuracy in position and size of brain activity obtained by near-infrared topography

被引:22
|
作者
Kawaguchi, H
Hayashi, T
Kato, T
Okada, E
机构
[1] Keio Univ, Dept Elect & Elect Engn, Kohoku Ku, Yokohama, Kanagawa 2238522, Japan
[2] Hamano Life Sci Res Fdn, Ogawa Labs Brain Funct Res, Shinjyuku Ku, Tokyo 1600015, Japan
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2004年 / 49卷 / 12期
关键词
D O I
10.1088/0031-9155/49/12/019
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Near-infrared (NIR) topography can obtain a topographical distribution of the activated region in the brain cortex. Near-infrared light is strongly scattered in the head, and the volume of tissue sampled by a source-detector pair on the head surface is broadly distributed in the brain. This scattering effect results in poor resolution and contrast in the topographic image of the brain activity. In this study, a one-dimensional distribution of absorption change in a head model is calculated by mapping and reconstruction methods to evaluate the effect of the image reconstruction algorithm and the interval of measurement points for topographic imaging on the accuracy of the topographic image. The light propagation in the head model is predicted by Monte Carlo simulation to obtain the spatial sensitivity profile for a source-detector pair. The measurement points are one-dimensionally arranged on the surface of the model, and the distance between adjacent measurement points is varied from 4 mm to 28 mm. Small intervals of the measurement points improve the topographic image calculated by both the mapping and reconstruction methods. In the conventional mapping method, the limit of the spatial resolution depends upon the interval of the measurement points and spatial sensitivity profile for source-detector pairs. The reconstruction method has advantages over the mapping method which improve the results of one-dimensional analysis when the interval of measurement points is less than 12 mm. The effect of overlapping of spatial sensitivity profiles indicates that the reconstruction method may be effective to improve the spatial resolution of a two-dimensional reconstruction of topographic image obtained with larger interval of measurement points. Near-infrared topography with the reconstruction method potentially obtains an accurate distribution of absorption change in the brain even if the size of absorption change is less than 10 mm.
引用
收藏
页码:2753 / 2765
页数:13
相关论文
共 50 条
  • [21] Near-Infrared Spectroscopy Probe with Position Sensor
    Shuji Taue
    Mayumi Fukuda
    Hirotsugu Yamamoto
    Yoshio Hayasaki
    Nobuo Nishida
    Optical Review, 2005, 12 : 149 - 154
  • [22] Brain activity analysis for sound information using near-infrared spectroscopy
    Tonegawa, Yoichi
    Watanuki, Keiichi
    Nihon Kikai Gakkai Ronbunshu, C Hen/Transactions of the Japan Society of Mechanical Engineers, Part C, 2013, 79 (798): : 442 - 449
  • [23] Noncontact brain activity measurement system based on near-infrared spectroscopy
    Funane, Tsukasa
    Atsumori, Hirokazu
    Suzuki, Atsushi
    Kiguchi, Masashi
    APPLIED PHYSICS LETTERS, 2010, 96 (12)
  • [24] Functional near-infrared spectroscopy caps for brain activity monitoring: a review
    Kassab, Amal
    Le Lan, Jerome
    Vannasing, Phetsamone
    Sawan, Mohamad
    APPLIED OPTICS, 2015, 54 (03) : 576 - 586
  • [25] Brain imaging with near-infrared fluorophores
    Wang, Hao
    Mu, Xiaoyu
    Yang, Jiang
    Liang, Yongye
    Zhang, Xiao-Dong
    Ming, Dong
    COORDINATION CHEMISTRY REVIEWS, 2019, 380 : 550 - 571
  • [26] Spatiotemporal imaging of human brain activity by functional near-infrared spectroscopy
    Hoshi, Y
    Chen, SJ
    Tamura, M
    AMERICAN LABORATORY, 2001, 33 (20) : 35 - +
  • [27] Application of near-infrared spectroscopy to investigate brain activity: Clinical research
    Lichty, W
    Sakatania, K
    Xie, YX
    Zuo, HC
    OPTICAL SENSING, IMAGING, AND MANIPULATION FOR BIOLOGICAL AND BIOMEDICAL APPLICATIONS, 2000, 4082 : 34 - 39
  • [28] IDENTIFICATION OF EPILEPTIC FOCUS WITH MULTICHANNEL NEAR-INFRARED SPECTROSCOPIC TOPOGRAPHY (OPTIC TOPOGRAPHY)
    Maruta, Y.
    Fujii, M.
    Imoto, H.
    Nomura, S.
    Matsushige, T.
    Ichiyama, T.
    Yamakawa, T.
    Suzuki, M.
    EPILEPSIA, 2011, 52 : 165 - 165
  • [29] The near-infrared autofluorescence fingerprint of the brain
    Lifante, Jose
    del Rosal, Blanca
    Chaves-Coira, Irene
    Fernandez, Nuria
    Jaque, Daniel
    Ximendes, Erving
    JOURNAL OF BIOPHOTONICS, 2020, 13 (11)
  • [30] DYNAMIC MULTICHANNEL NEAR-INFRARED OPTICAL IMAGING OF HUMAN BRAIN ACTIVITY
    HOSHI, Y
    TAMURA, M
    JOURNAL OF APPLIED PHYSIOLOGY, 1993, 75 (04) : 1842 - 1846