Theoretical evaluation of accuracy in position and size of brain activity obtained by near-infrared topography

被引:22
|
作者
Kawaguchi, H
Hayashi, T
Kato, T
Okada, E
机构
[1] Keio Univ, Dept Elect & Elect Engn, Kohoku Ku, Yokohama, Kanagawa 2238522, Japan
[2] Hamano Life Sci Res Fdn, Ogawa Labs Brain Funct Res, Shinjyuku Ku, Tokyo 1600015, Japan
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2004年 / 49卷 / 12期
关键词
D O I
10.1088/0031-9155/49/12/019
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Near-infrared (NIR) topography can obtain a topographical distribution of the activated region in the brain cortex. Near-infrared light is strongly scattered in the head, and the volume of tissue sampled by a source-detector pair on the head surface is broadly distributed in the brain. This scattering effect results in poor resolution and contrast in the topographic image of the brain activity. In this study, a one-dimensional distribution of absorption change in a head model is calculated by mapping and reconstruction methods to evaluate the effect of the image reconstruction algorithm and the interval of measurement points for topographic imaging on the accuracy of the topographic image. The light propagation in the head model is predicted by Monte Carlo simulation to obtain the spatial sensitivity profile for a source-detector pair. The measurement points are one-dimensionally arranged on the surface of the model, and the distance between adjacent measurement points is varied from 4 mm to 28 mm. Small intervals of the measurement points improve the topographic image calculated by both the mapping and reconstruction methods. In the conventional mapping method, the limit of the spatial resolution depends upon the interval of the measurement points and spatial sensitivity profile for source-detector pairs. The reconstruction method has advantages over the mapping method which improve the results of one-dimensional analysis when the interval of measurement points is less than 12 mm. The effect of overlapping of spatial sensitivity profiles indicates that the reconstruction method may be effective to improve the spatial resolution of a two-dimensional reconstruction of topographic image obtained with larger interval of measurement points. Near-infrared topography with the reconstruction method potentially obtains an accurate distribution of absorption change in the brain even if the size of absorption change is less than 10 mm.
引用
收藏
页码:2753 / 2765
页数:13
相关论文
共 50 条
  • [11] Evaluation of Brain Activity Using Near-infrared Spectroscopy in Inflammatory Bowel Disease Patients
    Fujiwara, Tatsuo
    Kono, Soichi
    Katakura, Kyoko
    Abe, Kazumichi
    Takahashi, Atsushi
    Gunji, Naohiko
    Yokokawa, Aki
    Kawashima, Kazumasa
    Suzuki, Rieko
    Wada, Akira
    Miura, Itaru
    Yabe, Hirooki
    Ohira, Hiromasa
    SCIENTIFIC REPORTS, 2018, 8
  • [12] FALSE POSITIVES IN FUNCTIONAL NEAR-INFRARED TOPOGRAPHY
    Tachtsidis, Ilias
    Leung, Terence S.
    Chopra, Anchal
    Koh, Peck H.
    Reid, Caroline B.
    Elwell, Clare E.
    OXYGEN TRANSPORT TO TISSUE XXX, 2009, 645 : 307 - 314
  • [13] Near-infrared oximetry of the brain
    Madsen, PL
    Secher, NH
    PROGRESS IN NEUROBIOLOGY, 1999, 58 (06) : 541 - 560
  • [15] Near-infrared spectroscopic measurement of brain activity for syntactic processing
    Uchibori, A
    Kojima, T
    Tsunashima, H
    Shiozawa, T
    APBP 2004: SECOND ASIAN AND PACIFIC RIM SYMPOSIUM ON BIOPHOTONICS, PROCEEDINGS, 2004, : 50 - 51
  • [16] Near-infrared spectroscopy for functional imaging of human brain activity
    Gong, H
    Zeng, SQ
    Luo, QM
    1997 SHANGHAI INTERNATIONAL CONFERENCE ON LASER MEDICINE AND SURGERY, 1998, 3344 : 286 - 289
  • [17] Brain tissue oxygen evaluation by wireless near-infrared spectroscopy
    Wang, Che-Chuan
    Kuo, Jinn-Rung
    Chen, Yu-Chih
    Chio, Chung-Ching
    Wang, Jhi-Joung
    Lin, Bor-Shyh
    JOURNAL OF SURGICAL RESEARCH, 2016, 200 (02) : 669 - 675
  • [18] Evaluation and diagnosis of brain death by Functional near-infrared spectroscopy
    Pan, Boan
    Zhong, Fulin
    Huang, Xiaobo
    Pan, Lingai
    Lu, Sen
    Li, Ting
    ADVANCED BIOMEDICAL AND CLINICAL DIAGNOSTIC AND SURGICAL GUIDANCE SYSTEMS XV, 2017, 10054
  • [19] Impaired brain activity in cirrhotic patients with minimal hepatic encephalopathy: Evaluation by near-infrared spectroscopy
    Nakanishi, Hiroyuki
    Kurosaki, Masayuki
    Nakanishi, Kaoru
    Tsuchiya, Kaoru
    Noda, Takamasa
    Tamaki, Nobuharu
    Yasui, Yutaka
    Hosokawa, Takanori
    Ueda, Ken
    Itakura, Jun
    Anami, Kimitaka
    Asahina, Yasuhiro
    Enomoto, Nobuyuki
    Higuchi, Teruhiko
    Izumi, Namiki
    HEPATOLOGY RESEARCH, 2014, 44 (03) : 319 - 326
  • [20] Near-infrared spectroscopy probe with position sensor
    Taue, S
    Fukuda, M
    Yamamoto, H
    Hayasaki, Y
    Nishida, N
    OPTICAL REVIEW, 2005, 12 (02) : 149 - 154