Comparing the extent of breast cancer tumors through contrast-enhanced ultrasound vs B-mode, opposed with pathology: evergreen study

被引:7
|
作者
Shima, Hiroaki [1 ]
Okuno, Toshitaka [2 ]
Nakamura, Takashi [3 ]
Noro, Aya [4 ]
Noma, Midori [5 ]
Sato, Megumi [6 ]
Kaga, Terumi [7 ]
Mituzuka, Yukio [8 ]
Kamei, Keitaro [9 ]
Imayoshi, Yumi [9 ]
Ito, Toshikazu [10 ]
Kanazawa, Shinsaku [11 ]
Kato, Kumiko [12 ]
Kutomi, Goro [1 ]
Sekiguchi, Ryuzo [13 ]
Mori, Mitsuru [14 ]
Tadashi, Hasegawa [15 ]
Hirai, Toshiko [16 ]
Takemasa, Ichiro [1 ]
机构
[1] Sapporo Med Univ, Dept Surg Surg Oncol & Sci, Chuo Ku, S 1,W 16, Sapporo, Hokkaido 0608543, Japan
[2] Kobe City Nishi Kobe Med Ctr, Breast Surg, Kobe, Hyogo, Japan
[3] Nabari City Hosp, Nabari, Japan
[4] Mie Prefectural Gen Med Ctr, Yokaichi, Japan
[5] Hiroshima Prefectural Hosp, Hiroshima, Japan
[6] Hokkaido Univ Hosp, Sapporo, Hokkaido, Japan
[7] Obihiro Kyoukai Hosp, Obihiro, Hokkaido, Japan
[8] Toho Univ, Omori Med Ctr, Ota Ku, Tokyo, Japan
[9] Ogaki Municipal Hosp, Ogaki, Japan
[10] Rinku Gen Med Ctr, Izumisano, Japan
[11] Koga Community Hosp, Breast Surg, Yaizu, Japan
[12] Fukui Ken Saiseikai Hosp, Fukui, Japan
[13] Toho Univ, Ohashi Med Ctr, Meguro Ku, Tokyo, Japan
[14] Hokkaido Chitose Coll Rehabil, Chitose, Japan
[15] Sapporo Med Univ, Dept Surg Pathol, Sapporo, Hokkaido, Japan
[16] Nara Med Univ, Dept Gen Diagnost Imaging Ctr, Kashihara, Nara, Japan
关键词
Breast cancer; Contrast-enhanced ultrasound; Tumor measurement; Pathology; SIZE ASSESSMENT; PERFLUBUTANE; IMAGE;
D O I
10.1007/s12282-020-01176-y
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Background To prove the efficacy of contrast-enhanced ultrasound (CEUS) in determining the extent of resection, more evidence about B-mode and CEUS as opposed to pathology is required. We compared maximum tumor width measured on B-mode/CEUS images with that determined pathologically. Methods In this retrospective multicenter study, 152 operable breast cancer patients who had undergone both B-mode and CEUS were analyzed. Maximum tumor width on B-mode and CEUS, and on the postoperative pathological examination (P), was measured by the participating investigators. In addition, maximum width was assessed in B-mode and CEUS image sets by independent reviewers blinded to all patient information. We analyzed differences in maximum width between CEUS, B-mode and P. Results The mean widths as measured by the participating investigators were 15 +/- 7 mm (B-mode), 19 +/- 8 mm (CEUS), and 17 +/- 9 mm (P). The difference subtracted P from B-mode was - 3 +/- 7 mm (p < 0.0001), and that from CEUS was 1 +/- 6 mm (p = 0.0163). The mean widths as measured by the independent reviewers were 16 +/- 7 mm (B-mode) and 18 +/- 7 mm (CEUS). The difference subtracted P from B-mode was - 2 +/- 8 mm (p = 0.0114), while that from CEUS was 1 +/- 7 mm (p = 0.1921). Conclusions Maximum lesion width measurement showed a tendency to increase in the order of B-mode, to P and CEUS. The difference in measurement between P and B-mode was significant, but there was no significant between CEUS and P. These results provide additional information of tendency patterns in measuring the maximum lesion width through enhancement on CEUS.
引用
收藏
页码:405 / 413
页数:9
相关论文
共 50 条
  • [1] Comparing the extent of breast cancer tumors through contrast-enhanced ultrasound vs B-mode, opposed with pathology: evergreen study
    Hiroaki Shima
    Toshitaka Okuno
    Takashi Nakamura
    Aya Noro
    Midori Noma
    Megumi Sato
    Terumi Kaga
    Yukio Mituzuka
    Keitaro Kamei
    Yumi Imayoshi
    Toshikazu Ito
    Shinsaku Kanazawa
    Kumiko Kato
    Goro Kutomi
    Ryuzo Sekiguchi
    Mitsuru Mori
    Hasegawa Tadashi
    Toshiko Hirai
    Ichiro Takemasa
    Breast Cancer, 2021, 28 : 405 - 413
  • [2] PRESENTATION OF CHLOROMAS IN B-MODE ULTRASOUND AND CONTRAST-ENHANCED ULTRASOUND
    Trenker, Corinna
    Goerg, Christian
    Burchert, Andreas
    Michel, Christian
    Kipper, Katharina
    Westhoff, Christina carolin
    Keber, Corinna ulrike
    Zadeh, Ehsan Safai
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2022, 48 (09): : 1933 - 1940
  • [3] B-mode, power Doppler and contrast-enhanced power Doppler ultrasonography in the diagnosis of breast tumors
    Reinikainen, H
    Rissanen, T
    Päivänsalo, M
    Pääkkö, E
    Jauhiainen, J
    Suramo, I
    ACTA RADIOLOGICA, 2001, 42 (01) : 106 - 113
  • [4] Transcutaneous B-mode ultrasound (TUS) and contrast-enhanced ultrasound (CEUS) pattern of mediastinal tumors: a pictorial essay
    Zadeh, Ehsan Safai
    Dietrich, Christoph Frank
    Trenker, Corinna
    Alhayri, Amjad
    Goerg, Christian
    JOURNAL OF ULTRASONOGRAPHY, 2021, 21 (87) : E340 - E347
  • [5] Detection of colorectal cancer hepatic metastases with contrast-enhanced ultrasound: Comparison with conventional B-mode ultrasound
    Yarmenitis, S. D.
    Karantanas, A.
    Bakantaki, A.
    Papantoniou, Y.
    Gourtsoyiannis, N.
    DIGESTIVE DISEASES, 2007, 25 (01) : 86 - 93
  • [6] AREA MEASUREMENT OF CAROTID PLAQUE COMPARING B-MODE, DOPPLER COLOR AND CONTRAST-ENHANCED ULTRASOUND IMAGING
    Nyman, E.
    Vanoli, D.
    Gronlund, C.
    Naslund, U.
    Lindqvist, P.
    ATHEROSCLEROSIS, 2016, 252 : E191 - E191
  • [7] Evaluation of parietal pleural adhesion and invasion in subpleural lung cancer: value of B-mode ultrasound and contrast-enhanced ultrasound
    Zhang, Yuxin
    Zhang, Zhanwei
    Liao, Haixing
    Li, Maohan
    Xu, Cong
    Liang, Zechun
    He, Liantu
    Zhang, Shiyu
    Tang, Qing
    QUANTITATIVE IMAGING IN MEDICINE AND SURGERY, 2024, 14 (05) : 3302 - 3311
  • [8] FULLY AUTOMATED CAROTID PLAQUE SEGMENTATION IN COMBINED CONTRAST-ENHANCED AND B-MODE ULTRASOUND
    Akkus, Zeynettin
    Carvalho, Diego D. B.
    van den Oord, Stijn C. H.
    Schinkel, Arend F. L.
    Niessen, Wiro J.
    de Jong, Nico
    van der Steen, Antonius F. W.
    Klein, Stefan
    Bosch, Johan G.
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2015, 41 (02): : 517 - 531
  • [9] Usefulness of contrast-enhanced ultrasound with Sonazoid for evaluating liver abscess in comparison with conventional B-mode ultrasound
    Kishina, Manabu
    Koda, Masahiko
    Tokunaga, Shiho
    Miyoshi, Kennichi
    Fujise, Yuki
    Kato, Jun
    Matono, Tomomitsu
    Sugihara, Takaaki
    Murawaki, Yoshikazu
    HEPATOLOGY RESEARCH, 2015, 45 (03) : 337 - 342
  • [10] Comparative efficacy of contrast-enhanced ultrasound versus B-mode ultrasound in the diagnosis and monitoring of hepatic abscesses
    Dobek, Adam
    Kobierecki, Mateusz
    Ciesielski, Wojciech
    Grzasiak, Oliwia
    Kosztowny, Konrad
    Fabisiak, Adam
    Bialek, Piotr
    Stefanczyk, Ludomir
    POLISH JOURNAL OF RADIOLOGY, 2024, 89 : e470 - e479