Comparing the extent of breast cancer tumors through contrast-enhanced ultrasound vs B-mode, opposed with pathology: evergreen study

被引:7
|
作者
Shima, Hiroaki [1 ]
Okuno, Toshitaka [2 ]
Nakamura, Takashi [3 ]
Noro, Aya [4 ]
Noma, Midori [5 ]
Sato, Megumi [6 ]
Kaga, Terumi [7 ]
Mituzuka, Yukio [8 ]
Kamei, Keitaro [9 ]
Imayoshi, Yumi [9 ]
Ito, Toshikazu [10 ]
Kanazawa, Shinsaku [11 ]
Kato, Kumiko [12 ]
Kutomi, Goro [1 ]
Sekiguchi, Ryuzo [13 ]
Mori, Mitsuru [14 ]
Tadashi, Hasegawa [15 ]
Hirai, Toshiko [16 ]
Takemasa, Ichiro [1 ]
机构
[1] Sapporo Med Univ, Dept Surg Surg Oncol & Sci, Chuo Ku, S 1,W 16, Sapporo, Hokkaido 0608543, Japan
[2] Kobe City Nishi Kobe Med Ctr, Breast Surg, Kobe, Hyogo, Japan
[3] Nabari City Hosp, Nabari, Japan
[4] Mie Prefectural Gen Med Ctr, Yokaichi, Japan
[5] Hiroshima Prefectural Hosp, Hiroshima, Japan
[6] Hokkaido Univ Hosp, Sapporo, Hokkaido, Japan
[7] Obihiro Kyoukai Hosp, Obihiro, Hokkaido, Japan
[8] Toho Univ, Omori Med Ctr, Ota Ku, Tokyo, Japan
[9] Ogaki Municipal Hosp, Ogaki, Japan
[10] Rinku Gen Med Ctr, Izumisano, Japan
[11] Koga Community Hosp, Breast Surg, Yaizu, Japan
[12] Fukui Ken Saiseikai Hosp, Fukui, Japan
[13] Toho Univ, Ohashi Med Ctr, Meguro Ku, Tokyo, Japan
[14] Hokkaido Chitose Coll Rehabil, Chitose, Japan
[15] Sapporo Med Univ, Dept Surg Pathol, Sapporo, Hokkaido, Japan
[16] Nara Med Univ, Dept Gen Diagnost Imaging Ctr, Kashihara, Nara, Japan
关键词
Breast cancer; Contrast-enhanced ultrasound; Tumor measurement; Pathology; SIZE ASSESSMENT; PERFLUBUTANE; IMAGE;
D O I
10.1007/s12282-020-01176-y
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Background To prove the efficacy of contrast-enhanced ultrasound (CEUS) in determining the extent of resection, more evidence about B-mode and CEUS as opposed to pathology is required. We compared maximum tumor width measured on B-mode/CEUS images with that determined pathologically. Methods In this retrospective multicenter study, 152 operable breast cancer patients who had undergone both B-mode and CEUS were analyzed. Maximum tumor width on B-mode and CEUS, and on the postoperative pathological examination (P), was measured by the participating investigators. In addition, maximum width was assessed in B-mode and CEUS image sets by independent reviewers blinded to all patient information. We analyzed differences in maximum width between CEUS, B-mode and P. Results The mean widths as measured by the participating investigators were 15 +/- 7 mm (B-mode), 19 +/- 8 mm (CEUS), and 17 +/- 9 mm (P). The difference subtracted P from B-mode was - 3 +/- 7 mm (p < 0.0001), and that from CEUS was 1 +/- 6 mm (p = 0.0163). The mean widths as measured by the independent reviewers were 16 +/- 7 mm (B-mode) and 18 +/- 7 mm (CEUS). The difference subtracted P from B-mode was - 2 +/- 8 mm (p = 0.0114), while that from CEUS was 1 +/- 7 mm (p = 0.1921). Conclusions Maximum lesion width measurement showed a tendency to increase in the order of B-mode, to P and CEUS. The difference in measurement between P and B-mode was significant, but there was no significant between CEUS and P. These results provide additional information of tendency patterns in measuring the maximum lesion width through enhancement on CEUS.
引用
收藏
页码:405 / 413
页数:9
相关论文
共 50 条
  • [11] Contrast-enhanced ultrasound-guided radiofrequency ablation in inconspicuous hepatocellular carcinoma on B-mode ultrasound
    Kim, Eui Joo
    Kim, Yun Soo
    Shin, Seung Kak
    Kwon, Oh Sang
    Choi, Duck Joo
    Kim, Ju Hyun
    TURKISH JOURNAL OF GASTROENTEROLOGY, 2017, 28 (06): : 446 - 452
  • [12] Contrast-enhanced ultrasound allows for interventions of hepatic lesions which are invisible on convential B-mode
    Schlottmann, K
    Klebl, F
    Zorger, N
    Feuerbach, S
    Schölmerich, J
    ZEITSCHRIFT FUR GASTROENTEROLOGIE, 2004, 42 (04): : 303 - 310
  • [13] Evaluation and Classification of Incidentally Detected Splenic Lesions Based on B-Mode and Contrast-Enhanced Ultrasound
    Zadeh, Ehsan Safai
    Goerg, Christian
    Post, Clemens
    Alhyari, Amjad
    Trenker, Corinna
    Dietrich, Christoph F.
    Findeisen, Hajo
    ULTRASCHALL IN DER MEDIZIN, 2023, 44 (06): : 637 - 644
  • [14] Fusion of Intraoperative 3D B-mode and Contrast-Enhanced Ultrasound Data for Automatic Identification of Residual Brain Tumors
    Ilunga-Mbuyamba, Elisee
    Lindner, Dirk
    Gabriel Avina-Cervantes, Juan
    Arlt, Felix
    Rostro-Gonzalez, Horacio
    Cruz-Aceves, Ivan
    Chalopin, Claire
    APPLIED SCIENCES-BASEL, 2017, 7 (04):
  • [15] The difference between tumor width on a contrast-enhanced ultrasound and the extent of pathological breast cancer
    Noro, Aya
    Shima, Hiroaki
    Hirai, Toshiko
    Noma, Midori
    Nakamura, Takashi
    Sato, Emi
    Kaga, Terumi
    Mitsuzuka, Yukio
    Kamei, Keitaro
    Imayoshi, Yumi
    Ito, Toshikazu
    Kanazawa, Shinsaku
    Kato, Kumiko
    Sekiguchi, Ryuzo
    Kutomi, Goro
    Mori, Mitsuru
    Hasegawa, Tadashi
    Takemasa, Ichiro
    Okuno, Toshitaka
    CANCER RESEARCH, 2020, 80 (04)
  • [16] GUIDING AND CONTROLLING PERCUTANEOUS PANCREAS BIOPSIES WITH CONTRAST-ENHANCED ULTRASOUND: TARGET LESIONS ARE NOT LOCALIZED ON B-MODE ULTRASOUND
    Wei, Ying
    Yu, Xiao-Ling
    Liang, Ping
    Cheng, Zhi-Gang
    Han, Zhi-Yu
    Liu, Fang-Yi
    Yu, Jie
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2015, 41 (06): : 1561 - 1569
  • [17] B-Mode Ultrasound and Contrast-Enhanced Ultrasound Pattern of Focal Extramedullary Hematopoiesis of the Spleen in a Patient with Myeloproliferative Disease
    Huynh, M. Q.
    Barth, P.
    Sohlbach, K.
    Neubauer, A.
    Goerg, C.
    ULTRASCHALL IN DER MEDIZIN, 2009, 30 (03): : 297 - 299
  • [18] Comparative Study of Qualitative and Quantitative Analyses of Contrast-Enhanced Ultrasound and the Diagnostic Value of B-Mode and Color Doppler for Common Benign Tumors in the Parotid Gland
    Yan, Meiying
    Xu, Dong
    Chen, Liyu
    Zhou, Lingyan
    FRONTIERS IN ONCOLOGY, 2021, 11
  • [19] Contrast-enhanced ultrasonography vs B-mode ultrasound for visualization of intima-media thickness and detection of plaques in human carotid arteries
    Shah, Benoy N.
    Chahal, Navtej S.
    Kooner, Jaspal S.
    Senior, Roxy
    ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2017, 34 (05): : 723 - 730
  • [20] Sonographic patterns of renal lymphoma in B-mode imaging and in contrast-enhanced ultrasound (CEUS)-A retrospective evaluation
    Trenker, C.
    Neesse, A.
    Goerg, C.
    EUROPEAN JOURNAL OF RADIOLOGY, 2015, 84 (05) : 807 - 810