Inspection of Insulators on High-Voltage Power Transmission Lines

被引:45
|
作者
Han, Sunsin [1 ]
Hao, Ru [2 ]
Lee, Jangmyung [1 ]
机构
[1] Pusan Natl Univ, Dept Elect Engn, Pusan 609735, South Korea
[2] Pusan Natl Univ, Pusan 609735, South Korea
关键词
Inspection; low-frequency harmonics; mobile robot; porcelain insulator; SINGULAR-VALUE DECOMPOSITION; HARMONIC RETRIEVAL; NOISE;
D O I
10.1109/TPWRD.2009.2028534
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Porcelain insulators are widely used in overhead high-voltage power transmission lines in order to provide adequate insulation to withstand switching and lightning over voltages. Since the useful serviceable life of the individual insulator element and insulator strings is hard to predict, they must be verified periodically to insure that adequate reliability is maintained at all times. Over the years, many testing methods have been used for this purpose, each one with its own advantages and disadvantages. A novel insulator inspection method using low-frequency harmonics is proposed for human safety. Using this inspection device with a mobile robot can keep humans far away from power transmission lines. The working principle of this new method is based on the relationship between low-frequency harmonic components and the defective characteristic of the insulators. In this paper, the retrieval of low-frequency harmonics from complex noise is solved by using extended high-order cumulants (HOCs). The concept of cross mixing is newly proposed and the harmonic retrieval method using the slice of the sixth-order time-averaged moment poly-spectra is introduced based on this condition. It can be successfully used in the real environment where a full spectrum of multiplicative and colored noises exists. In the experiment, as one of our dedicated contributions, low-frequency harmonics and the defective characteristics of popular porcelain insulators are illustrated.
引用
收藏
页码:2319 / 2327
页数:9
相关论文
共 50 条
  • [41] Expliner – toward a practical robot for inspection of high-voltage lines
    Debenest P.
    Guarnieri M.
    Takita K.
    Fukushima E.F.
    Hirose S.
    Tamura K.
    Kimura A.
    Kubokawa H.
    Iwama N.
    Shiga F.
    Morimura Y.
    Ichioka Y.
    Springer Tracts in Advanced Robotics, 2010, 62 : 45 - 55
  • [42] HIGH-VOLTAGE PULSE CHARACTERISTICS OF SUPERCONDUCTING TRANSMISSION LINES
    CUMMINGS, AJ
    WILSON, AR
    JOURNAL OF APPLIED PHYSICS, 1966, 37 (08) : 3297 - &
  • [43] DANGER OVERHEAD + HIGH-VOLTAGE TRANSMISSION-LINES
    DIAMOND, S
    OMNI, 1978, 1 (03) : 37 - 37
  • [44] TRANSMISSION OF PROTECTION SIGNALS VIA HIGH-VOLTAGE LINES
    ALSLEBEN, E
    ELEKTROTECHNISCHE ZEITSCHRIFT B-AUSGABE, 1967, 19 (04): : 89 - &
  • [45] ON EFFECTS OF HIGH-VOLTAGE TRANSMISSION-LINES - RESPONSE
    HAUPT, RC
    AMERICAN JOURNAL OF PUBLIC HEALTH, 1984, 74 (09) : 1042 - 1043
  • [46] Live maintenance robot for high-voltage transmission lines
    Jiang, Wei
    Yan, Yu
    Zhang, An
    Yu, Lianqing
    Zuo, Gan
    Li, Hong Jun
    Chen, Wei
    INDUSTRIAL ROBOT-THE INTERNATIONAL JOURNAL OF ROBOTICS RESEARCH AND APPLICATION, 2019, 46 (05): : 711 - 718
  • [47] FAULT PREDICTION ON HIGH-VOLTAGE TRANSMISSION-LINES
    HALASA, GH
    ELECTRIC POWER SYSTEMS RESEARCH, 1982, 5 (04) : 281 - 284
  • [48] TRANSMISSION CHARACTERISTICS OF HIGH-VOLTAGE LINES AT CARRIER FREQUENCIES
    EGGIMANN, F
    SENN, W
    MORF, K
    BROWN BOVERI REVIEW, 1977, 64 (08): : 449 - 459
  • [49] What drives opposition to high-voltage transmission lines?
    Cain, Nicholas L.
    Nelson, Hal T.
    LAND USE POLICY, 2013, 33 : 204 - 213
  • [50] HIGH-VOLTAGE TRANSMISSION-LINES - PROS AND CONS
    BINGHAM, GS
    CIVIL ENGINEERING, 1978, 48 (09): : 89 - 89