Inspection of Insulators on High-Voltage Power Transmission Lines

被引:45
|
作者
Han, Sunsin [1 ]
Hao, Ru [2 ]
Lee, Jangmyung [1 ]
机构
[1] Pusan Natl Univ, Dept Elect Engn, Pusan 609735, South Korea
[2] Pusan Natl Univ, Pusan 609735, South Korea
关键词
Inspection; low-frequency harmonics; mobile robot; porcelain insulator; SINGULAR-VALUE DECOMPOSITION; HARMONIC RETRIEVAL; NOISE;
D O I
10.1109/TPWRD.2009.2028534
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Porcelain insulators are widely used in overhead high-voltage power transmission lines in order to provide adequate insulation to withstand switching and lightning over voltages. Since the useful serviceable life of the individual insulator element and insulator strings is hard to predict, they must be verified periodically to insure that adequate reliability is maintained at all times. Over the years, many testing methods have been used for this purpose, each one with its own advantages and disadvantages. A novel insulator inspection method using low-frequency harmonics is proposed for human safety. Using this inspection device with a mobile robot can keep humans far away from power transmission lines. The working principle of this new method is based on the relationship between low-frequency harmonic components and the defective characteristic of the insulators. In this paper, the retrieval of low-frequency harmonics from complex noise is solved by using extended high-order cumulants (HOCs). The concept of cross mixing is newly proposed and the harmonic retrieval method using the slice of the sixth-order time-averaged moment poly-spectra is introduced based on this condition. It can be successfully used in the real environment where a full spectrum of multiplicative and colored noises exists. In the experiment, as one of our dedicated contributions, low-frequency harmonics and the defective characteristics of popular porcelain insulators are illustrated.
引用
下载
收藏
页码:2319 / 2327
页数:9
相关论文
共 50 条
  • [11] Design of High-Voltage Power Transmission Insulators Based on Ultrasonic Technology
    Du, Yuwei
    Wang, Heyang
    Zhao, Yufei
    Sun, Liqiong
    Geng, Yingsan
    Wang, Jianhua
    Wang, Zhenxing
    IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2023, 70 (10) : 10740 - 10749
  • [12] Impact of high-voltage power transmission lines on photovoltaic power production
    Fathabadi, Hassan
    SOLAR ENERGY, 2018, 163 : 78 - 83
  • [13] Remote monitoring of power quality of high-voltage transmission lines
    Zhao Yanchao
    Jiang Dong
    Kong Deshan
    Cui Lin
    PROCEEDINGS OF 2019 14TH IEEE INTERNATIONAL CONFERENCE ON ELECTRONIC MEASUREMENT & INSTRUMENTS (ICEMI), 2019, : 984 - 991
  • [14] EFFECT OF HIGH-VOLTAGE LINES OF POWER TRANSMISSION ON A LOGGING CABLE
    RUVINSKII, VA
    GRIGORYAN, PM
    AKOPYAN, YV
    NEFTYANOE KHOZYAISTVO, 1979, (08): : 50 - 52
  • [15] A NOVEL INSPECTION ROBOT MOVING ON HIGH-VOLTAGE POWER TRANSMISSION LINE
    Tao Guanghong
    Fang Lijin
    ASSISTIVE ROBOTICS, 2016, : 275 - 282
  • [16] Research on the algorithm of detecting insulators in high-voltage transmission lines using UAV images
    Si, Yachao
    Gao, Jiajie
    Zhao, Mingzhan
    Xu, Xiaojun
    SIGNAL IMAGE AND VIDEO PROCESSING, 2024, 18 (SUPPL 1) : 395 - 406
  • [17] HIGH-VOLTAGE POWER TRANSMISSION
    BARTHOLD, LO
    PFEIFFER, HG
    SCIENTIFIC AMERICAN, 1964, 210 (05) : 38 - &
  • [18] High-Voltage Transmission Line Inspection Robot
    Gulzar, Muhammad Azib
    Kumar, Kundan
    Javed, Muhammad Asad
    Sharif, Muhammad
    2018 INTERNATIONAL CONFERENCE ON ENGINEERING & EMERGING TECHNOLOGIES (ICEET), 2018, : 17 - 23
  • [19] Control structure establishment and control method design for high-voltage (HV) power transmission lines inspection robot
    Wang, Peng
    Liu, Feng
    Mei, Shengwei
    Wang, Kefei
    Qinghua Daxue Xuebao/Journal of Tsinghua University, 2011, 51 (07): : 921 - 927
  • [20] QUALITY ASSURANCE IN CONSTRUCTION OF HIGH-VOLTAGE POWER TRANSMISSION-LINES
    DORING, M
    ENERGIETECHNIK, 1978, 28 (08): : 316 - 317