High-throughput, high-sensitivity genetic mutation detection by tandem single-strand conformation polymorphism/heteroduplex analysis capillary array electrophoresis

被引:56
|
作者
Kourkine, IV [1 ]
Hestekin, CN [1 ]
Buchholz, BA [1 ]
Barron, AE [1 ]
机构
[1] Northwestern Univ, Dept Chem Engn, Evanston, IL 60208 USA
关键词
D O I
10.1021/ac020025b
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
We present the first optimization of linear polyacrylamide (LPA)-based DNA separation matrixes for an automated tandem microchannel single-strand conformation polymorphism (SSCP)/heteroduplex analysis (HA) method, implemented in capillary arrays dynamically coated with poly(N-hydroxyethylacrylamide) (polyDuramide). An optimized protocol for sample preparation allowed both SSCP and HA species to be produced in one step in a single tube and distinguished in a single electrophoretic analysis. A simple, two-color fluorescent sample labeling and detection strategy enabled unambiguous identification of all DNA species in the electropherogram, both single-and double-stranded. Using these protocols and a panel of 11 p53 mutant DNA samples in comparison with wildtype, we employed high-throughput capillary array electrophoresis (CAE) to carry out a systematic and simultaneous optimization of LPA weight-average molar mass (M-w) and concentration for SSCP/HA peak separation. The combination of the optimized LPA matrix (6% LPA, M-w 600 kDa) and a hydrophilic, adsorbed polyDuramide wall coating was found to be essential for resolution of CAE-SSCP/HA peaks and yielded sensitive mutation detection in all 11 p53 samples initially studied. A larger set of 32 mutant DNA specimens was then analyzed using these optimized tandem CAE-SSCP/HA protocols and materials and yielded 100% sensitivity of mutation detection, whereas each individual method yielded lower sensitivity on its own (93% for SSCP and 75% for HA). This simple, highly sensitive tandem SSCP/HA mutation detection method should be easily translatable to electrophoretic analyses on microfluidic devices, due to the ease of the capillary coating protocol and the low viscosity of the matrix.
引用
收藏
页码:2565 / 2572
页数:8
相关论文
共 50 条
  • [1] High-throughput single-strand conformation polymorphism analysis by capillary electrophoresis
    Ren, JC
    JOURNAL OF CHROMATOGRAPHY B, 2000, 741 (02): : 115 - 128
  • [2] High-throughput single-strand conformation polymorphism analysis on a microfabricated capillary array electrophoresis device
    Tian, HJ
    Emrich, CA
    Scherer, JR
    Mathies, RA
    Andersen, PS
    Larsen, LA
    Christiansen, M
    ELECTROPHORESIS, 2005, 26 (09) : 1834 - 1842
  • [3] High-throughput single strand conformation polymorphism mutation detection by automated capillary array electrophoresis: Validation of the method
    Andersen, PS
    Jespersgaard, C
    Vuust, J
    Christiansen, M
    Larsen, LA
    HUMAN MUTATION, 2003, 21 (02) : 116 - 122
  • [4] High-throughput single nucleotide polymorphism typing by fluorescent single-strand conformation polymorphism analysis with capillary electrophoresis
    Doi, K
    Doi, H
    Noiri, E
    Nakao, A
    Fujita, T
    Tokunaga, K
    ELECTROPHORESIS, 2004, 25 (06) : 833 - 838
  • [5] Mutation detection by high throughput single strand conformation polymorphism using automated capillary array electrophoresis: Validation of sensitivity.
    Andersen, PS
    Jespersgaard, C
    Vuust, J
    Christiansen, M
    Larsen, LA
    EUROPEAN JOURNAL OF HUMAN GENETICS, 2002, 10 : 293 - 293
  • [6] High resolution for single-strand conformation polymorphism analysis by capillary electrophoresis
    Ozawa, S
    Sugano, K
    Sonehara, T
    Fukuzono, S
    Ichikawa, A
    Fukayama, N
    Taylor, M
    Miyahara, Y
    Irie, T
    ANALYTICAL CHEMISTRY, 2004, 76 (20) : 6122 - 6129
  • [7] High-throughput single-strand conformation polymorphism analysis of an LPL gene mutation by temperature-controlled on-chip capillary electrophoresis
    Ono, Koichi
    Koike, Mitsuyasu
    Ohse, Takuhito
    Takagi, Atsuko
    Ikeda, Yasuyuki
    2006 INTERNATIONAL CONFERENCE ON MICROTECHNOLOGIES IN MEDICINE AND BIOLOGY, 2006, : 198 - +
  • [8] Single-strand conformation polymorphism analysis using capillary array electrophoresis for large-scale mutation detection
    Lars Allan Larsen
    Cathrine Jespersgaard
    Paal Skytt Andersen
    Nature Protocols, 2007, 2 : 1458 - 1466
  • [9] Single-strand conformation polymorphism analysis using capillary array electrophoresis for large-scale mutation detection
    Larsen, Lars Allan
    Jespersgaard, Cathrine
    Andersen, Paal Skytt
    NATURE PROTOCOLS, 2007, 2 (06) : 1458 - 1466
  • [10] Efficient genetic mutation screening by combined microchannel electrophoresis single-strand conformation polymorphism/heteroduplex analysis.
    Kourkine, IV
    Magnusdottir, SO
    Buchholz, BA
    Doherty, EAS
    Barron, AE
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2001, 222 : U87 - U87