High-throughput, high-sensitivity genetic mutation detection by tandem single-strand conformation polymorphism/heteroduplex analysis capillary array electrophoresis

被引:56
|
作者
Kourkine, IV [1 ]
Hestekin, CN [1 ]
Buchholz, BA [1 ]
Barron, AE [1 ]
机构
[1] Northwestern Univ, Dept Chem Engn, Evanston, IL 60208 USA
关键词
D O I
10.1021/ac020025b
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
We present the first optimization of linear polyacrylamide (LPA)-based DNA separation matrixes for an automated tandem microchannel single-strand conformation polymorphism (SSCP)/heteroduplex analysis (HA) method, implemented in capillary arrays dynamically coated with poly(N-hydroxyethylacrylamide) (polyDuramide). An optimized protocol for sample preparation allowed both SSCP and HA species to be produced in one step in a single tube and distinguished in a single electrophoretic analysis. A simple, two-color fluorescent sample labeling and detection strategy enabled unambiguous identification of all DNA species in the electropherogram, both single-and double-stranded. Using these protocols and a panel of 11 p53 mutant DNA samples in comparison with wildtype, we employed high-throughput capillary array electrophoresis (CAE) to carry out a systematic and simultaneous optimization of LPA weight-average molar mass (M-w) and concentration for SSCP/HA peak separation. The combination of the optimized LPA matrix (6% LPA, M-w 600 kDa) and a hydrophilic, adsorbed polyDuramide wall coating was found to be essential for resolution of CAE-SSCP/HA peaks and yielded sensitive mutation detection in all 11 p53 samples initially studied. A larger set of 32 mutant DNA specimens was then analyzed using these optimized tandem CAE-SSCP/HA protocols and materials and yielded 100% sensitivity of mutation detection, whereas each individual method yielded lower sensitivity on its own (93% for SSCP and 75% for HA). This simple, highly sensitive tandem SSCP/HA mutation detection method should be easily translatable to electrophoretic analyses on microfluidic devices, due to the ease of the capillary coating protocol and the low viscosity of the matrix.
引用
收藏
页码:2565 / 2572
页数:8
相关论文
共 50 条
  • [31] Fluorescent-based Single-strand Conformation Polymorphism/Heteroduplex Capillary Electrophoretic Mutation Analysis of the P53 Gene
    Chunxia Zhao
    Guowang Xu
    Xianzhe Shi
    Jianmei Ma
    Yan Zhang
    Shen Lv
    Qianfeng Weng
    Qing Yang
    Analytical Sciences, 2004, 20 : 1001 - 1005
  • [32] High-throughput mutation detection method to scan BRCA1 and BRCA2 based on heteroduplex analysis by capillary array electrophoresis
    Esteban-Cardeñosa, E
    Duran, M
    Infante, M
    Velasco, E
    Miner, C
    CLINICAL CHEMISTRY, 2004, 50 (02) : 313 - 320
  • [33] Single temperature endonuclease-enhanced single-strand conformation polymorphism/heteroduplex mutation analysis: evaluation of the method
    Hofman-Bang, J
    Christiansen, M
    SCANDINAVIAN JOURNAL OF CLINICAL & LABORATORY INVESTIGATION, 2004, 64 (06): : 605 - 607
  • [34] Detection of the major mutation M467T causing cystinuria by single-strand conformation polymorphism analysis using capillary electrophoresis
    Klepárnik, K
    Grochová, D
    Skopková, Z
    Adam, T
    ELECTROPHORESIS, 2004, 25 (01) : 57 - 64
  • [35] A single-strand conformation polymorphism method for the large-scale analysis of mutations/polymorphisms using capillary array electrophoresis
    Kukita, Y
    Higasa, K
    Baba, S
    Nakamura, M
    Manago, S
    Suzuki, A
    Tahira, T
    Hayashi, K
    ELECTROPHORESIS, 2002, 23 (14) : 2259 - 2266
  • [36] A single-strand conformation polymorphism method for the large-scale analysis of mutations/polymorphisms using capillary array electrophoresis
    Kukita, Yoji
    Higasa, Koichiro
    Baba, Shingo
    Nakamura, Michihiro
    Manago, Sachi
    Suzuki, Akari
    Tahira, Tomoko
    Hayashi, Kenshi
    2002, Wiley-VCH Verlag (23)
  • [37] Single-strand conformation polymorphism analysis to detect the p53 mutation in colon tumor samples by capillary electrophoresis
    Ru, QH
    Jing, HE
    Luo, GA
    Huang, Q
    JOURNAL OF CHROMATOGRAPHY A, 2000, 894 (1-2) : 171 - 177
  • [38] Single-strand conformation polymorphism analysis by microchip electrophoresis for the rapid detection of point mutation in human obesity gene
    Kang, Seong Ho
    Jang, Sooyoung
    Park, Sang-Kyu
    BULLETIN OF THE KOREAN CHEMICAL SOCIETY, 2006, 27 (09) : 1346 - 1352
  • [39] Improvements of polymerase chain reaction and capillary electrophoresis single-strand conformation polymorphism methods in microbial ecology: Toward a high-throughput method for microbial diversity studies in soil
    Zinger, Lucie
    Gury, Jerome
    Giraud, Frederic
    Krivobok, Serge
    Gielly, Ludovic
    Taberlet, Pierre
    Geremia, Roberto A.
    MICROBIAL ECOLOGY, 2007, 54 (02) : 203 - 216
  • [40] Improvements of Polymerase Chain Reaction and Capillary Electrophoresis Single-Strand Conformation Polymorphism Methods in Microbial Ecology: Toward a High-throughput Method for Microbial Diversity Studies in Soil
    Lucie Zinger
    Jérôme Gury
    Frédéric Giraud
    Serge Krivobok
    Ludovic Gielly
    Pierre Taberlet
    Roberto A. Geremia
    Microbial Ecology, 2007, 54 : 203 - 216