DNA microarray reading by an intensified CCD camera with picosecond time resolution

被引:0
|
作者
Cubeddu, R [1 ]
D'Andrea, C [1 ]
Pifferi, A [1 ]
Taroni, P [1 ]
Torricelli, A [1 ]
Valentini, G [1 ]
Battaglia, C [1 ]
Consolandi, C [1 ]
Rossi-Bernardi, L [1 ]
Salani, G [1 ]
De Bellis, G [1 ]
机构
[1] Politecn Milan, INFM, Dipartimento Fis, I-20133 Milan, Italy
关键词
D O I
暂无
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
In the present paper we describe a novel approach for DNA microarray reading. We used an intensified CCD camera with picosecond time resolution either for single shot image acquisition or for time resolved measurements. We characterized the time resolution of the system. Then, we demonstrated that two fluorescent markers used for oligonucleotide labeling can be discriminated in the time domain instead of the spectral one. Finally, we applied our system to read a PNA microarray. (C) 1999 Optical Society of America.
引用
收藏
页码:120 / 122
页数:3
相关论文
共 50 条
  • [1] CCD READOUT OF A PICOSECOND STREAK CAMERA WITH AN INTENSIFIED CCD
    LEMONIER, M
    RICHARD, JC
    CAVAILLER, C
    MENS, A
    RAZE, G
    PROCEEDINGS OF THE SOCIETY OF PHOTO-OPTICAL INSTRUMENTATION ENGINEERS, 1985, 491 : 706 - 712
  • [2] Time-resolved DNA-microarray reading by an intensified CCD for ultimate sensitivity
    Valentini, G
    D'Andrea, C
    Comelli, D
    Pifferi, A
    Taroni, P
    Torricelli, A
    Cubeddu, R
    Battaglia, C
    Consolandi, C
    Salani, G
    Rossi-Bernardi, L
    De Bellis, G
    OPTICS LETTERS, 2000, 25 (22) : 1648 - 1650
  • [3] Picosecond Raman spectroscopy with a fast intensified CCD camera for depth analysis of diffusely scattering media
    Ariese, Freek
    Meuzelaar, Heleen
    Kerssens, Marleen M.
    Buijs, Joost B.
    Gooijer, Cees
    ANALYST, 2009, 134 (06) : 1192 - 1197
  • [4] Intensified cooled integrating CCD camera
    Lynch, TF
    IMAGE INTENSIFIERS AND APPLICATIONS; AND CHARACTERISTICS AND CONSEQUENCES OF SPACE DEBRIS AND NEAR-EARTH OBJECTS, 1998, 3434 : 34 - 36
  • [5] A PICOSECOND TIME RESOLUTION STREAK CAMERA SYSTEM
    HOU, X
    ZHANG, RD
    NIU, HB
    CHAO, JL
    CHEN, JR
    WANG, ZH
    PROCEEDINGS OF THE SOCIETY OF PHOTO-OPTICAL INSTRUMENTATION ENGINEERS, 1985, 491 : 1072 - 1076
  • [6] High-speed gated, high-resolution digital intensified CCD camera
    Kume, H
    Kakihara, T
    Nakamura, H
    25TH INTERNATIONAL CONGRESS ON HIGH-SPEED PHOTOGRAPHY AND PHOTONICS, 2003, 4948 : 38 - 44
  • [7] INTENSIFIED CCD CAMERA SYSTEM FOR PLASMA DIAGNOSTICS
    SMITH, J
    CHASE, R
    GARCIA, J
    HSIEH, C
    VASLOW, D
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1985, 56 (05): : 871 - 871
  • [8] INTENSIFIED CCD ULTRAFAST STREAK CAMERA SYSTEM
    CHENG, J
    TRIPP, GR
    COLEMAN, LW
    BULLETIN OF THE AMERICAN PHYSICAL SOCIETY, 1978, 23 (07): : 880 - 880
  • [9] HIGH TIME RESOLUTION FLUORESCENCE IMAGING WITH A CCD CAMERA
    LASSERROSS, N
    MIYAKAWA, H
    LEVRAM, V
    YOUNG, SR
    ROSS, WN
    JOURNAL OF NEUROSCIENCE METHODS, 1991, 36 (2-3) : 253 - 261
  • [10] Application of time-gated, intensified CCD camera in the brain imaging system
    Sawosz, P.
    Kacprzak, M.
    Zolek, N.
    Maniewski, R.
    Liebert, A.
    WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING, VOL 25, PT 2 - DIAGNOSTIC IMAGING, 2009, 25 : 553 - 555