Accounting for pharmacokinetic differences in dual-tracer receptor density imaging

被引:24
|
作者
Tichauer, K. M. [1 ]
Diop, M. [2 ]
Elliott, J. T. [3 ]
Samkoe, K. S. [3 ]
Hasan, T. [4 ]
Lawrence, K. St. [2 ]
Pogue, B. W. [3 ,4 ]
机构
[1] IIT, Chicago, IL 60616 USA
[2] Univ Western Ontario, London, ON N6A 4V2, Canada
[3] Dartmouth Coll, Thayer Sch Engn, Hanover, NH 03755 USA
[4] Massachusetts Gen Hosp, Wellman Ctr Photomed, Boston, MA 02114 USA
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2014年 / 59卷 / 10期
关键词
fluorescence imaging; tracer kinetics; cancer; xenograft mouse model; epidermal growth factor receptor; affibodies; DRUG-BINDING; MODEL; TISSUES; VOLUME;
D O I
10.1088/0031-9155/59/10/2341
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Dual-tracer molecular imaging is a powerful approach to quantify receptor expression in a wide range of tissues by using an untargeted tracer to account for any nonspecific uptake of a molecular-targeted tracer. This approach has previously required the pharmacokinetics of the receptor-targeted and untargeted tracers to be identical, requiring careful selection of an ideal untargeted tracer for any given targeted tracer. In this study, methodology capable of correcting for tracer differences in arterial input functions, as well as binding-independent delivery and retention, is derived and evaluated in a mouse U251 glioma xenograft model using an Affibody tracer targeted to epidermal growth factor receptor (EGFR), a cell membrane receptor overexpressed in many cancers. Simulations demonstrated that blood, and to a lesser extent vascular-permeability, pharmacokinetic differences between targeted and untargeted tracers could be quantified by deconvolving the uptakes of the two tracers in a region of interest devoid of targeted tracer binding, and therefore corrected for, by convolving the uptake of the untargeted tracer in all regions of interest by the product of the deconvolution. Using fluorescently labeled, EGFR-targeted and untargeted Affibodies (known to have different blood clearance rates), the average tumor concentration of EGFR in four mice was estimated using dual-tracer kinetic modeling to be 3.9 +/- 2.4 nM compared to an expected concentration of 2.0 +/- 0.4 nM. However, with deconvolution correction a more equivalent EGFR concentration of 2.0 +/- 0.4 nM was measured.
引用
收藏
页码:2341 / 2351
页数:11
相关论文
共 50 条
  • [31] Parathyroid Imaging: The Importance of Pinhole Collimation with Both Single- and Dual-Tracer Acquisition
    Klingensmith, William C., III
    Koo, Phillip J.
    Summerlin, Adam
    Fehrenbach, Bradley W.
    Karki, Ramesh
    Shulman, Benjamin C.
    Raeburn, Christopher D.
    McIntyre, Robert C., Jr.
    JOURNAL OF NUCLEAR MEDICINE TECHNOLOGY, 2013, 41 (02) : 99 - 104
  • [32] Three-dimensional convolutional neural networks for simultaneous dual-tracer PET imaging
    Xu, Jinmin
    Liu, Huafeng
    PHYSICS IN MEDICINE AND BIOLOGY, 2019, 64 (18):
  • [33] Microscopic lymph node tumor burden quantified by macroscopic dual-tracer molecular imaging
    Kenneth M Tichauer
    Kimberley S Samkoe
    Jason R Gunn
    Stephen C Kanick
    P Jack Hoopes
    Richard J Barth
    Peter A Kaufman
    Tayyaba Hasan
    Brian W Pogue
    Nature Medicine, 2014, 20 : 1348 - 1353
  • [34] Microscopic lymph node tumor burden quantified by macroscopic dual-tracer molecular imaging
    Tichauer, Kenneth M.
    Samkoe, Kimberley S.
    Gunn, Jason R.
    Kanick, Stephen C.
    Hoopes, P. Jack
    Barth, Richard J.
    Kaufman, Peter A.
    Hasan, Tayyaba
    Pogue, Brian W.
    NATURE MEDICINE, 2014, 20 (11) : 1348 - 1353
  • [35] Comparison of dual-tracer subtraction imaging and sestamibi SPECT in preoperative localization of parathyroid adenoma
    Lezaic, L.
    Fettich, J.
    Rep, S.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2005, 32 : S102 - S102
  • [36] Dual-tracer PET/CT in the management of hepatocellular carcinoma
    Chiu, Keith Wan Hang
    Chiang, Chi Leung
    Chan, Kenneth Sik Kwan
    Hui, Yuan
    Ren, Jingyun
    Wei, Xiaojuan
    Ng, Kwok Sing
    Lee, Ho Fun Victor
    Chia, Nam Hung
    Cheung, Tan-To
    Chan, Stephen
    Chan, Albert Chi-Yan
    Ng, Kwok Chai Kelvin
    Seto, Wai Kay Walter
    Khong, Pek-Lan
    Kong , Feng-Ming
    JHEP REPORTS, 2024, 6 (07)
  • [37] Measurement of protein digestibility in humans by a dual-tracer method
    Devi, Sarita
    Varkey, Aneesia
    Sheshshayee, M. S.
    Preston, Thomas
    Kurpad, Anura, V
    AMERICAN JOURNAL OF CLINICAL NUTRITION, 2018, 107 (06): : 984 - 991
  • [38] Dual-tracer PET studies without arterial sampling
    Koeppe, R
    Joshi, A
    Frey, K
    Snyder, S
    Kilbourn, M
    Fessler, J
    NEUROIMAGE, 2004, 22 : T115 - T116
  • [39] Dual-tracer fluorescence thermometry measurements in a heated channel
    Kim, Myeongsub
    Yoda, Minami
    EXPERIMENTS IN FLUIDS, 2010, 49 (01) : 257 - 266
  • [40] Dual-Tracer PET/CT in HCC Staging and Management
    不详
    JOURNAL OF NUCLEAR MEDICINE, 2018, 59 (05) : 15N - 15N