Measurement of Radon concentration in College of Education, Ibn Al- Haitham buildings using Rad-7 and CR-39 detector

被引:5
|
作者
Salim, Duaa Abed [1 ]
Ebrahiem, Sameera Ahmed [1 ]
机构
[1] Univ Baghdad, Coll Educ Ibn Al Haitham, Dept Phys, Baghdad, Iraq
关键词
Radioactive; Radon; Radon measurement techniques; Rad-7; detector;
D O I
10.1016/j.egypro.2018.11.258
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
In this present work, radon concentration was measured indoor buildings in the College of Education for Pure Sciences / Ibn AlHaitham University of Baghdad using Rad-7and CR-39 detector for compare, because this college is one of the old buildings, also there are some closed places inside it, where increase radon gas in these places will cause to health hazard. Rad-7 monitor is used to measure the radon concentration in three ways in the air, water and soil. In this work, Rad-7 was measured radon concentration in the air which is direct method with compared CR-39 detector which considers passive method of measurable. Have been measured for half an hour in every room using Rad-7 with appropriate conditions for measurement, where the device was recorded higher reads in two samples Fl and F2, the values were (59.6 Bq/m(3)) and (48.2 Bq/m(3)) respectively and the lowest read in the sample (El), the value was (5.43Bq/m(3)). When using CR-39 detectors were placed two detectors of CR-39 in every room for (30) days, the results were (445.868Bq/m(3)) and (436.791Bq/m(3)) respectively because these places without ventilation and very old buildings and the lowest read in the sample (Cl), the value was (17.412Bq/m(3)) because these places were open and with high ventilation. All results that recorded by using Rad-7 monitor were within the range allowed globally recorded by (ICRP) but the results of CR-39 were within the range allowed globally recorded by (ICRP) which were (200-300)Bq/m(3) except two samples Fl and F2. (C) 2019 The Authors. Published by Elsevier Ltd.
引用
收藏
页码:918 / 925
页数:8
相关论文
共 20 条
  • [1] Measuring Radon Concentration Levels in Fertilizers using CR-39 Detector
    Aswood, Murtadha Sh
    Jaafar, Mohamad S.
    Bauk, Sabar
    MICRO/NANO SCIENCE AND ENGINEERING, 2014, 925 : 610 - +
  • [2] MEASUREMENT OF RADON CONCENTRATION USING BARE CR-39 TRACK DETECTORS
    YONEHARA, H
    KIMURA, H
    AOYAMA, T
    MIFUNE, M
    SAKANOUE, M
    SUGAHARA, T
    JOURNAL OF RADIATION RESEARCH, 1987, 28 (01) : 73 - 73
  • [3] Measuring the radon concentration in housings connecting the radon spring bathroom by using the CR-39 detector
    Meng, Wenbin
    Qin, Changzhu
    Bi, Zhiying
    Feng, Yushui
    Yuanzineng Kexue Jishu/Atomic Energy Science and Technology, 1996, 30 (06): : 561 - 564
  • [4] DETERMINATION OF THE ABSOLUTE RADON CONCENTRATION IN AIR USING AN ELECTROSTATIC METHOD AND CR-39 DETECTOR
    TETEREV, YG
    TRETYAKOVA, SP
    GOLOVCHENKO, AN
    ILIC, R
    SKVARC, J
    RADIATION MEASUREMENTS, 1995, 25 (1-4) : 645 - 646
  • [6] Determine the Contaminations of Radon in the Drinking Water Using NTDs (CR-39) and RAD7 Detectors
    Najeba F. Salih
    Arabian Journal for Science and Engineering, 2021, 46 : 6061 - 6074
  • [7] Determine the Contaminations of Radon in the Drinking Water Using NTDs (CR-39) and RAD7 Detectors
    Salih, Najeba F.
    ARABIAN JOURNAL FOR SCIENCE AND ENGINEERING, 2021, 46 (06) : 6061 - 6074
  • [8] Detection of Radon Exhalation from Various Building Materials Using CR-39, RAD7, and Biosensors
    Albazoni, H. J.
    Almayahi, B. A.
    ATOM INDONESIA, 2022, 48 (03) : 225 - 230
  • [9] MEASUREMENT OF CONCENTRATIONS OF RADON AND ITS DAUGHTERS IN INDOOR ATMOSPHERE USING CR-39 NUCLEAR TRACK DETECTOR
    KHAN, AJ
    SHARMA, KC
    VARSHNEY, AK
    PRASAD, R
    TYAGI, RK
    INDIAN JOURNAL OF PURE & APPLIED PHYSICS, 1988, 26 (06) : 425 - 427
  • [10] MEASUREMENT OF CONCENTRATIONS OF RADON AND ITS DAUGHTERS IN INDOOR ATMOSPHERE USING CR-39 NUCLEAR TRACK DETECTOR
    FARID, SM