MEASUREMENT OF CONCENTRATIONS OF RADON AND ITS DAUGHTERS IN INDOOR ATMOSPHERE USING CR-39 NUCLEAR TRACK DETECTOR

被引:6
|
作者
FARID, SM
机构
[1] Department of Physics, University of Swaziland, Kwaluseni, Swaziland
来源
关键词
NUCLEAR TRACK DETECTOR; CALIBRATION FACTOR; INDOOR RADON; THORON; PAEE; EFFECTIVE DOSE EQUIVALENT;
D O I
10.1016/0969-8078(93)90079-J
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
This paper presents the results of the measurements of indoor Rn-222 and daughter levels in houses of different types located in different parts of Bangladesh. The passive time-integrated method of using a solid state nuclear track detector (CR-39) was employed for measuring both the Rn-222 gas concentration as well as the potential al pha energy exposure (PAEE) level from the short lived daughters of Rn-222. The Rn-222 concentration from cup exposure and the PAEE from the bare exposure were obtained directly from the track density using calibration curves. A total of 275 exposures were made in the bare mode in 15 locations and 71 exposures in the cup mode in 6 locations. The geometric mean PAEE level obtained is 9.5 mWL with a geometric standard deviation of 1.9. The corresponding value for Rn-222 concentration are 61.3 Bq.m-3 and 2.4. The total data was collected over a period of one and a half years. The monthly variation of the geometric mean of PAEE is also shown. The annual effective dose equivalent has been estimated for each location by using the conversion factor of 9 mSv per WLM as obtained from ICRP-50. The average PAEE level obtained from the total data is below the intervention level as suggested by US EPA. However, the individual averages for each location show that in 8 out of 15 locations intervention may be considered and in others no intervention is called for. The Rn-222 concentrations at the seven locations are equal or less than the equilibrium equivalent Rn-222 concentration value as suggested by EPA. Attempts have also been made to see the variation in the PAEE levels according to different type of construction material used for the houses.
引用
收藏
页码:331 / 334
页数:4
相关论文
共 50 条
  • [1] MEASUREMENT OF CONCENTRATIONS OF RADON AND ITS DAUGHTERS IN INDOOR ATMOSPHERE USING CR-39 NUCLEAR TRACK DETECTOR
    KHAN, AJ
    SHARMA, KC
    VARSHNEY, AK
    PRASAD, R
    TYAGI, RK
    INDIAN JOURNAL OF PURE & APPLIED PHYSICS, 1988, 26 (06) : 425 - 427
  • [2] CALIBRATION OF A CR-39 PLASTIC TRACK DETECTOR FOR THE MEASUREMENT OF RADON AND ITS DAUGHTERS IN DWELLINGS
    KHAN, AJ
    VARSHNEY, AK
    PRASAD, R
    TYAGI, RK
    RAMACHANDRAN, TV
    NUCLEAR TRACKS AND RADIATION MEASUREMENTS, 1990, 17 (04): : 497 - 502
  • [4] COMPARATIVE-STUDY OF CR-39 PLASTIC TRACK DETECTOR AND SURFACE-BARRIER SEMICONDUCTOR DETECTOR IN MEASUREMENT OF RADON AND ITS DAUGHTERS IN AIR
    YAMAMOTO, M
    NAKANISHI, T
    IWATA, E
    HIGUCHI, S
    JOURNAL OF RADIATION RESEARCH, 1987, 28 (01) : 74 - 74
  • [5] α-Spectroscopy on CR-39 track detectors for the dosimetry of radon daughters
    Mozzo, P.
    Trotti, F.
    Temporin, A.
    Lanciai, M.
    Predicatori, F.
    Righetti, F.
    Tacconi, A.
    Environment International, 1997, 22 (SUPPL. 1):
  • [6] MEASUREMENT OF INDOOR RADON CONCENTRATION BY CR-39
    ZHAO, YH
    ZHAO, CD
    HAO, XH
    ZHOU, PD
    GUO, SL
    NUCLEAR TRACKS AND RADIATION MEASUREMENTS, 1993, 22 (1-4): : 523 - 526
  • [7] Radon Exhalation Rate from Building Materials Using CR-39 Nuclear Track Detector
    Topcu, N.
    Bicak, D.
    Cam, S.
    Erees, F. S.
    INDOOR AND BUILT ENVIRONMENT, 2013, 22 (02) : 384 - 387
  • [8] DETERMINATION OF DETECTION EFFICIENCY FOR RADON AND RADON DAUGHTERS WITH CR-39 TRACK DETECTOR - A MONTE-CARLO STUDY
    NIKEZIC, D
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1994, 344 (02): : 406 - 414
  • [9] Measurements of radon concentrations in groundwaters from Swaziland using CR-39 nuclear track detectors
    Farid, SM
    APPLIED RADIATION AND ISOTOPES, 1996, 47 (03) : 383 - 385
  • [10] THE MEASUREMENT OF AIRBORNE ALPHA-PARTICLES USING A CR-39 NUCLEAR TRACK DETECTOR
    WONG, CF
    ESPIE, N
    MEARA, LA
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH, 1983, 206 (03): : 569 - 573